Rev. 6/19/14 ERRATA – Thermodynamics: Concepts & Applications p. 55 - Add red background to Eq. 2.20 p. 64 - Fig. 2.8: 500 kPa should be 400 kPa p. 69 - 5 lines from bottom (not counting footnote): “Eqn. 3.32” should be “Eqn. 2.32” p. 83 - 4 lines above Self Test: delete “fairly” p. 86 - Italic T & h in table p. 86 - h(320 K) should be h(820 K) 2 locations p. 91 - 4 lines from bottom of text; 1st sub-bullet: “and” should be “or” p. 110 - Horizontal scale label should be v not s p. 112 - Fig. 2.29: Remove red overlying curve over top of steam dome p. 116 - Footnote: “superseded” not “superceded” p. 119 - Fig. 2.33 RH axis units: Add “sub m” to “lb”, i.e., “lbm” p. 122 - Possibly add add’l approximation: u = cvT p. 124 - Fig. 2.34: Tweak triple point pointer to point at bold dot p. 130 - Footnote 17: Change “temperature” to “pressure” p. 147 - Prob. 2.34: Add period after “P2” p. 153 - Prob. 2.105: Insert “1 kg of” after “contains” p. 153 - Problem 2.112: Change “0.136” to “1.36” kg p. 158 - Denominator of Eqn. 2A.3: “ ‘ ” should be “ ! ” p. 178 - First unnumbered equation: Change bold “V” to unbold “V” p. 208 - Prob. 3.22: Change “170°C” to “169°C” p. 231 - Vertical scale label should be “P” not “T” Rev. 6/19/14 p. 254 - Caption to Fig. 4.16; Courtesy line should read “Photographs (b, c, d) by Paul Ruby, (a) by Sibtosh Pal …” p. 262 - Need to redraw figure to show lead wires & perspective more accurately. p. 287 - 2nd line above Self Test: “polystyrene” p. 299 - First line: Capital W in “With” p. 299 - 2nd equation: Q-dot not Q p. 299 - 10th line: “yields” not “yield” p. 316 - Ex. 5.14: Change T2 to T4 in drawing following problem statement. p. 320 - Self Test 5.11: Answer should be “9.5 m/s” p. 321 - Eqn. 5.28: Delete subscript “in” on “m-dot” p. 338 - Enthalpies in problem 5.80 should be 2856.5 kJ/kg and 2562.2 kJ/kg, respectively. Note change in Answers to Selected Problems (p. 719) for this problem. p. 347 - 3rd line: “generated” should be “generalized” p. 349 - Self Test 6.1: Delete “and pressure” p. 361 - Side bar: “Chapter 1” should be “Chapter 2” p. 363 - Note that regeneration must be used to meet only 2 reservoir, constant-T requirement in Stirling cycle. p. 364 - Fig. 6.14: “W-dot-1-2” should be “W-dot-4-1” p. 370 - Sentence above Eqn. 6.22a should begin “For Case II” (not Case I), whereas sentence below Eqn. 6.22a should begin “For Case I” (not Case II). p. 371 - Eqns. 6.24a,b need red backgrounds. p. 377 - Self Test 6.6: Add masses to parenthetical material: “(2 kg copper and 2.5 kg iron)” p. 378 - 4th line in Analysis: “6.3588” should be “7.3588” p. 379 - Last entry 3rd line of table “6.2207” should be “7.2207” Rev. 6/19/14 p. 392 - Answer to Self Test 6.9: Insert solidus before (1/Pº), i.e., “/(1/Pº)” p. 399 - Eqn. 6.59: “ – “ should be “+” p. 400 - Eqn. 6.61a: Add subscript “1” to “S” and “V” p. 400 - Eqn. 6.61b: Add subscript “1” to “S” p. 400 - Eqn. 6.61c: Add subscript “1” to “s” p. 401 - 8th line form bottom:”120/0.14808” should be “101.25/0.1672” p. 408 - Last term in first equation should have negative sign, i.e., “–T0(s1 – s0)”; same error in following equation in which numbers are substituted. p. 408 - 8th line: Change “15,270” to “4780” p. 408 - 9th line: Change “W” to “kW” p. 415 - Sketch in 6.2: Turbine: “W-dot-in” should read “W-dot-out” p. 416 - Problem 6.8: Replace “An ideal gas” with “Air” p. 418 - Problem 6.27 Part B looks bogus – need to check. p. 421 - Problem 6.70: Remove circle from integral sign. p. 580 - Problem 6.111: “mole function” should read “mole fraction” p. 427 - Problem 6.137: Change “fill” to “full” p. 455 - 5th line under subheading Isentropic Flows: Inequalities are reversed. Should read: “P0 > Pb ≥ Pc” p. 472 - Eqn. 7.34d: Add “g” in denominator of last term p. 489 - Change values for h1 and h2 (2 locations) to “1798.6” and “861.1”, respectively, to agree with Table C.2 values p. 495 - Eqn. 7.51: Add subscript “C” to m-dot on RHS p. 495 - Eqn. 7.53a: Add subscript “H” to m-dot on RHS p. 495 - Eqn. 7.53b: Add subscript “C” to m-dot on RHS Rev. 6/19/14 p. 506 - Ch 7 Problem Subject Areas: Change “7.21” to “7.20” & change “7.22” to “7.21”. p. 510 - Prob. 7.32: Change “at the nozzle exit Pe” to “in tank B” p. 513 - Problem 7.70: insert “per unit mass of working fluid” after “work done”. p. 522 - 5th line from bottom of text: “reversibility” should be “reversibly”. p. 583 - 6th line: Replace spurious Greek symbols with left & right square brackets p. 593 - Example 12.15: Change “mm Hg” to “in Hg” in problem statement and in Analysis section. p. 595 - 2nd line: Replace “ ≥ ” with “ / ” p. 603 - 4th equation from bottom: Replace “hl,3” with “hf,3” p. 615 - Part B: Portion should read: “(economizer, steam generator, superheater, and reheater combined)” p. 617 - Problem 8.38: Change “Example 8.10” to “Example 8.8” p. 617 - Problem 8.39: Change “Example 8.9” to “Example 8.7” p. 617 - Problem 8.41: Change “Example 8.11” to “Example 8.9” p. 617 - Problem 8.43: Formula for iso-octane should be “C10H18” p. 619 - Problem 8.55: Replace “compression” with “heat addition” p. 620 - Problem 8.59: Add “per unit mass” to the end of the last sentence. p. 620 - Problem 8.60: Add “per unit mass” to the end of the last sentence. p. 620 - Problem 8.63: Change pressure ratio from “8.5” to “12.5” p. 621 - Problem 8.70: Change pressure ratio from “8.5” to “12.5” p. 621 - Problem 8.70: Add to Part C “The turbine inlet temperature is 1500 K.” Modify Part D, 2nd & 3rd lines to read “thermal efficiency for no regeneration. Discuss.” p. 621 - Problem 8.70: Add to Part C “The turbine inlet temperature is 1500 K.” Rev. 6/19/14 Modify Part D, 2nd & 3rd lines to read “thermal efficiency for no regeneration. Discuss.” p. 628 - Prob. 8.126: Reword: “…0.15 MPa. Does any moisture condense? If so, determine the moisture condensation rate (kg/min). If not, determine the relative humidity.” p. 628 - Problem 8.135: Insert “(dry basis)” after “4-lbm mass of air” and after “1lbm mass of air”. p. 629 - Problem 8.139: Add “at 1 atm” to the end of the last sentence. p. 629 - Problem 8.143: Add word “flow” after word “mass” in Parts B & C. p. 632 - Problem 8.170: Change “is maintained” to “contains air”. p. 539 - Add arrowhead to “Steam out” p. 683 - Property headings on columns 3-7 should have subscripts “g” p. 694 - Table heading should be “Table G.2A” not “G2.A”. Similarly for tables B – E. p. 677 - Table D.3V heading: Replace “24.0” with “26.0” p. 717 - Round answers to Problem 2.17c and 2.17d to five significant digits: 51,386 kJ/kmol, 56,364 kJ/kmol p. 718 - Prob. 2.96: Answer should be 0.00230 kg p. 718 - Prob. 2.112: Answer should be 454 K p. 718 - Problem 3.8: A. 0.04852, B. 0.02536 kg, 0.05997 m3, C. 0.002316 kg, 2.40 x 10-5 m3 p. 719 - Answer to Problem 5.80 with revised enthalpies (2856.5 kJ/kg and 2562.2 kJ/kg) is 769.4 m/s. p. 728 - Index entry “flowrate” should be “flow rate”