Tender Document

advertisement
Government of West Bengal
DIRECTORATE OF ANIMAL RESOURCES & ANIMAL HEALTH
Prani Sampad Bhavan, 2nd floor, LB-2, Sector-III, Salt Lake City, Kolkata-700 098
Ph: 2335-1145 Fax: 2335-1187 E-mail: dahvswb@rediffmail.com Website: www.darah.org
NOTICE INVITING E-TENDER (2nd call) FOR RATE CONTRACT LABORATORY
INSTRUMENTS, LAB. REAGENTS, LAB. KITS & LAB. MOLECULAR REAGENTS
(Submission of bid through NIC e-tender portal http://www.wbtenders.gov.in)
NIT # WBARD/DARAH/LAB INST. Etc./NIT-03/2P-105(A)/11/15-16
Date of Issue: 5th May, 2015
The Director of Animal Husbandry & Veterinary Services, West Bengal on behalf of
the Governor to the State of West Bengal is going for e-tender (2nd call) for preparing the
rate schedule of Laboratory instruments for the year 2015-16.
On-line tenders are invited only from MANUFACTURERS/AUTHORISED
DISTRIBUTORS/DEALERS for rate contract of Laboratory Instruments & Reagents etc.
to the following decentralized units under this Directorate.
1. Office of the Dy. Director, A.R.D. & Parisad Officer, South 24 Paraganas (Alipore),
North 24 Paraganas (Barasat), Howrah, Purba Medinipur (Tamluk), Dakshin Dinajpur
and Jalpaiguri. Central Medical Stores, Sub-depots at Nadia, Bankura, Uttar Dinajpur,
Murshidabad, Coochbehar, Siliguri, Bardhaman, Hooghly (Chinsurah), Birbhum,
Purulia, Paschim Medinipur and Malda.
2. Office of the Joint Director, A.R.D., Zone-I/II/III/IV Division, P.O. Bardhaman/
Kalyani/Siliguri/Baharampur, Dist. Bardhaman/Nadia/Darjeeling/ Murshidabad.
3. Office of the Joint Director, A.R.D., State Livestock Farm, Kalyani, Nadia / Composite
State Animal Husbandry Farm, Salboni, Paschim Medinipur.
4. Office of the Joint Director, A.R.D., Institute of Animal Health & Veterinary
Biologicals, 37, Belgachia Road, Kolkata-37.
5. Office of the Addl. Director, A.R.D., Haringhata Farm, P.O. Mohanpur, Dist. Nadia.
6. Office of the Dy. Director, A.R.D., Poultry-Marketing, State Poultry Farm, 42, Graham
Road, Tollygunge, Kolkata-40.
7. Office of the District Executive Officer of all district; Station Director-I, Frozen Semen Bull
Station, Haringhata/Salboni/Beldanga; Deputy Project Director, Bull Mother Farm,
Haringhata; Office-in-Charge, Bull Mother Farm, Salboni all under Paschim Banga
Go-Sampad Bikash Sanstha (A Govt. of West Bengal Organization).
Laboratory instruments etc., as per catalogue enclosed, are classified in the following groups:
Sl. No.
Name of the Instrument
Acc. Unit
Group-A- Laboratory Instruments
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
Laminar Flow(Horizontal)
Small autoclave vertical
Fully automatic vertical autoclave, GMP model
Bio Safety Cabinet
Class- II
Horizontal High pressure Cylindrical Stem Sterilizer (Autoclave- Semi-automatic:
Single door)
One chamber CO2 Incubator with work chamber volume approx. 300 litres
Refrigerator with data logger (Vertical)
Horizontal Low Temp. Freezer(-60°C)
Inverted Microscope
Refrigerated Micro centrifuge
Micro Centrifuge for PCR plate
Temperature Indicator with alarm devices and thermal data loggers
Manual Rotary Microtome
Ordinary Centrifuge Machine
Tissue Homogenizer
Automatic Rotary Microtome
UPS 15 KVA on-line uninterrupted Power Supply
Gr. A/01 Pc./01
Gr. A/01 Pc./02
Gr. A/01 Pc./ 03
Gr. A/01 Pc./04
Gr. A/01 Pc./ 05
Gr. A/01 Pc./ 06
Gr. A/01 Pc./07
Gr. A/01 Pc./ 08
Gr. A/01 Pc./ 09
Gr. A/01 Pc./ 10
Gr. A/01 Pc./ 11
Gr. A/01 Pc./ 12
Gr. A/01 Pc./ 13
Gr. A/01 Pc./ 14
Gr. A/01 Pc./ 15
Gr. A/01 Pc./16
Gr. A/01 Pc./ 17
Contd. Page-2
Page-2
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Battery for UPS- 15 KVA on line
Gr. A/01 Pc./18
UPS(Uninterrupted Power Supply) 5 KVA on line
Gr. A/01 Pc./19
Battery for UPS- 5 KVA on line
Gr. A/01 Pc./20
Pilot Freeze Dryer
Gr. A/01 Pc./21
Clean room clogs with cuffs
Gr. A/01 Pc./22
Programmable peristaltic pump
Gr. A/01 Pc./23
Membrane pump
Gr. A/01 Pc./24
Ready to connect single use filtration unit
Gr. A/01 Pc./25
Door Interlock Switches
Gr. A/01 Pc./26
Multichannel Pipette
Gr. A/01 Pc./27
Multichannel Pipette
Gr. A/01 Pc./28
Thermo cycler with three independent blocks
Gr. A/01 Pc./29
Automated DNA/RNA extraction system
Gr. A/01 Pc./30
Portable gel electrophoresis system with real time transilluminator
Gr. A/01 Pc./31
Computer controlled rapid Microbial Identification system
Gr. A/01 Pc./32
Binocular microscope
Gr. A/01 Pc./33
Automatic Tissue Processor
Gr. A/01 Pc./34
UV-VIS Spectrophotometer
Gr. A/01 Pc./35
Gr. A/01 Pc./36
Ampoule Freeze Dryer
Research adjustable volume pipettes, Autoclavable with tip box
Gr. A/01 Pc./37
Gr. A/01 Pc./38
Research adjustable volume pipettes, Autoclavable with tip box
Gr. A/01 Pc./39
Research adjustable volume pipettes, Autoclavable with tip box
PCR Plate centrifuge
Gr. A/01 Pc./40
Group-B: Laboratory Reagents & Other Glass/ Plastic materials
Polypropylene bottle Autoclavable
Gr. B/Lab. Regt./100 Pc./01
Gr. B/Lab. Regt./100 Pc./02
Rubber stopper for Polypropylene bottle
Gr. B/Lab. Regt./100 Pc./03
Aluminum cap (20 mm diam.),
Gr. B/Lab. Regt./360 pcs./04
Neutral Glass vial
Neoprene Rubber cap for Neutral Glass vial 3 ml. capacity, 13 mmOD Gr. B/Lab. Regt./2000 pcs./05
Aluminium caps, coloured and non colour for Neutral Glass vial
Gr. B/Lab. Regt./5000pcs./06
Gr. B/Lab. Regt./10 pc./07
Gel pack(Ice cold pack)
Gr. B/Lab. Regt./50 pc./08
Syringe Filter (Membrane Filter)
Gel pack(Ice cold pack)
Gr. B/Lab. Regt./10 pc./09
Tissue Culture (TC)Flask with filter cap
Gr. B/Lab. Regt./18 pc./10
Tissue Culture (TC)Flask
Gr. B/Lab. Regt./18 pc./11
Thioglycollate Broth(BQ vaccine Media)
Gr. B/Lab. Regt./01 pc./12
Standard Nutrient Broth (HS Vaccine Media)
Gr. B/Lab. Regt./01 pc./13
Formaldehyde 37% (formalin)
Gr. B/Lab. Regt./01 pc./14
Gr. B/Lab. Regt./01 pc./15
Glycerol-98% Purified
Aluminum Hydroxide Gel (3 % W/V, Liquid type) pH-7
Gr. B/Lab. Regt./01 pc./16
Yeast Extract Powder
Gr. B/Lab. Regt./01 pc./17
EMEM
Gr. B/Lab. Regt./10 bot./18
L-Glutamine
Gr. B/Lab. Regt./10 vial/19
Group – C : Laboratory Kits
Classical Swine Fever Antigen ELISA test kits
Gr. C/Lab. Kit./1kit/1
M. bovis Antibody ELISA test kit
Gr. C/Lab. Kit./5kit/2
Bacillus anthracis (common)PCR kit
Gr. C/Lab. Kit./1kit/3
RT PCR kit
Gr. C/Lab. Kit./1kit/4
PRRS Antibody ELISA test kit
Gr. C/Lab. Kit./1 kit/5
Bovine Herpes virus(BHV-1) real time PCR kit
Gr. C/Lab. Kit./150 tests/ 6
Bovine viral Diarrhoea virus (BVD) real time RT PCR Kit Gr. C/Lab. Kit./150 tests/ 7
Quantitative(q) PCR mastermix kit
Gr. C/Lab. Kit./ 100 Reaction/Kits/ 8
Quantitative(q)RT PCR master mix kit
Gr. C/Lab. Kit./ 100 Reaction/Kits/ 9
DNA purification kit for whole blood and tissue
Gr. C/Lab. Kit./ 250 purification / 1 kit /10
Viral RNA purification kit
Gr. C/Lab. Kit./ 50 purification /1kits/11
Rapid AIV Antigen Test Kit
Gr. C/Lab. Kit /30 tests/pack/12
Contd. Page-3
Page-3
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25
26.
27.
28.
29.
30.
31.
32.
33.
1.
2.
3.
4.
5.
IBD Virus Antigen Test Kit
Gr. C/Lab. Kit /10 tests/kit/13
NDV ELISA Kit (Ab. Detection)
Gr. C/Lab. Kit /480tests/pack/14
Rapid IBD test kit
Gr. C/Lab. Kit /10 tests/pack/15
Rapid NDV Antigen Test kit
Gr. C/Lab. Kit /10 tests/pack/16
Sandwitch ELISA test Kit for BSE Purification of PrPsc.
Gr. C/Lab. Kit /192 tests/Kit/17
Avian Influenza Virus subtype (H5) Real time kits
Gr. C/Lab. Kit /150 tests/pack/18
Avian Influenza Virus subtype (H7) Real time kits
Gr. C/Lab. Kit /150 tests/pack/19
Avian Influenza Virus subtype (H9) Real time kits
Gr. C/Lab. Kit / 150 reactions/Kit /20
AIV antibody ELISA Kits
Gr. C/Lab. Kit /480tests/Kit/21
Rapid AIV subtype H5 antigen detection kit
Gr. C/Lab. Kit /25tests Kit /pack/22
Avian Influenza Virus subtype (H5) Antibody detection kits Gr. C/Lab. Kit /192tests/Kit/23
Avian Influenza Virus subtype (H7) Antibody detection kits Gr. C/Lab. Kit /192tests/Kit/24
Newcastle Disease (ND) Virus Real time kits
Gr. C/Lab. Kit /150 tests/pack/25
Avian Infectious Bronchitis Virus, Real Time Kits
Gr. C/Lab. Kit /150 tests/pack/26
Avian Adenovirus(Egg Drop Syndrome)
Gr. C/Lab. Kit /150 tests/pack/27
Mycoplasma gallisepticum Real Time Kits
Gr. C/Lab. Kit /150 tests/pack/28
Brucella genus Real Time kits
Gr. C/Lab. Kit /150 tests/pack/29
Camylobacter foetus Real Time Kits
Gr. C/Lab. Kit /150 tests/pack/30
Salmonella detection PCR kits
Gr. C/Lab. Kit /25 runs/kit/31
E coli 0157:H7 detection PCR kit
Gr. C/Lab. Kit /25 reactions/Kit/32
SYBR Green I PCR kits
Gr. C/Lab. Kit /200 runs/33
Group- D: Laboratory Molecular Reagents
Basic synthesis(Per base charges) for Primers
Gr. D/Lab. Regt./1 vial/1
Probe
Gr. D/Lab. Regt./1vial/2
Probe
Gr. D/Lab. Regt./1 vial /3
Primer, forward
Gr. D/Lab. Regt./ 1 vial /4
Primer, Reverse
Gr. D/Lab. Regt./1 vial/5
N.B. *Catalogue of Laboratory instruments along with specification and packing
unit is attached.
1. Uniform rate must be quoted applicable to the entire aforementioned units. Quoting of
separate rate against each of the above units will not be considered for acceptance.
2. Offered rate should remain valid for a period OF ONE YEAR FROM THE DATE OF
ACCEPTANCE OF THE TENDER and any extended period, if situation arises.
3. Necessary Earnest Money Deposit or valid exemption certificate along with
mandatory documents in Statutory & non-statutory cover are to be uploaded for
participation in the tender.
4. After publication of the N.I.T. in the newspapers, detailed catalogue along with terms
& conditions, BOQ (Bill of Quantities) may be obtained from the Website
http://www.wbtenders.gov.in at free of cost.
5. Tenders will be floated in two parts – one Technical Bid for technical proposal
(mandatory documents in Statutory & non-statutory cover) and other for Financial
Bid for quoting rate & VAT (whole amount) in BOQ’s in dedicated column.
6. Submission of on-line tender may be made by the bidder with the help of Digital
Signature Certificate (DSC).
7. The software shall make automatic encryption of the technical bid as well as
financial bid. No one will be able to open these two bids prior to schedule date & time
as fixed by the undersigned.
8. After evaluation of technical bid, those who will technically qualify, their financial bid
will be opened for evaluation.
9. Disclosure of rate other than BOQ will disqualify the bidder.
Continued on Page-4
Page-4
10. On-line bid submission will start on 12th May, 2015 at 4 pm in the e-tender portal viz.
http://wbtenders.gov.in.
11. Earnest Money Deposit should be submitted physically on or before 3rd June, 2015
up to 4 pm at the office of the Director, AH & VS, West Bengal Prani Sampad
Bhavan, LB-2, Sector-III, Salt Lake City, Kolkata-700 098.
12. Sample along with Literature of quoted item/s should be submitted physically before
sample selection committee on stipulated date, place & time that will be
communicated later on.
13. On-line tenders in two parts i.e. Technical Bid (Part-I) & Financial Bid (Part-II) are to
be submitted up to 5 pm on 2nd June, 2015 for the aforementioned N.I.T.
14. Technical Bid Opening Date is tentatively fixed at 11 am on 3rd June, 2015. Other
activities i.e. date of uploading List of Technically qualified bidders, date of opening of
financial bid etc. will be communicated later on.
15. The above schedule is fixed, however, the undersigned reserves the right to change the
date of activities in case of any exigencies through a notice in the departmental website
viz. www.darahwb.org & Notice Board at above addressed office.
The entire tender documents including N.I.T, terms & conditions for submission
of tender and BOQs are part & parcel of the tender.
The Bidder should abide by all the tender terms & condition and upload the
same as a token of acceptance.
The undersigned reserves the right to reject and/or cancel all tenders at any
stage without assigning any reason thereof and will not bound to accept lowest bid.
Sd/(Dr. S. Bose)
Director of Animal Husbandry &
Veterinary Services, West Bengal
CATALOGUE
Items for tender list
Sl. No.
Name of the Instrument
Specification with presentation
Acc. Unit
Pkg. Unit
Group-A- Laboratory Instruments
1.
Laminar Flow(Horizontal)
2.
Small autoclave vertical
3.
Fully automatic vertical
autoclave, GMP model
4.
Bio
Safety
Class- II
Cabinet
Horizontal Laminar Flow Clean Air Work Station ,Work Space – 4’ x 2’ x 2’Power Supply – 230V
AC 1-ø 50 Hz, 500 Watts HEPA Filter – 1220Work Space – 1186 x 610 x 577 mm Overall Dimension
– 1302 x 915 x 1425 mm, Option:- Polycarbonate front door with gas filled hinges for 4 feet. System:HEPA Filter, Pre Filter, Motor blower assembly, Stainless steel 304 Work Table, Glass side panels,
U-V light, fluorescent lights (in excess of zoo lux)Air / Gas regulator, Pressure monitor from 0 to 25
mm, Electrical outlet with switch to be supplied with polycarbonate Front door with hinges. Filters:Separator less Minipleat antimicrobial EU-13 HEPA filter with an efficiency of 99.97% on
monodisporse,0.3 micron challenge, biocidal anti-microbial prefilter conforming to EU-6 rating.
Media is impenitently bactericidal & fungicidal. Performance:- Air Cleanliness: Class M 3.5 (US FED
209E) 150 Class 5 [ISO 14644-1 : 1999(E)]
Inner chamber made of SS 304 grade & outer of MS covered with SS sheet. Fitted with pressure gauze
steam release valve safety valve and paddle fitting device to work on 220 V AC size of inner chamber
20” x 12” with basket capacity 40 liters. 2 kW SS lid. should be equipped with timer .
Fully automatic with digital temperature and time controller( 4 sensors 3 temp + 1 pressure) with
printer interface to connect to dot matrix printer, to be supplied with printer, of size 22X 30 ( diameter
X height in inches) on site validation service, calibration certificate with IQ, OQ and PQ protocols
should be provided with all the accessories including printer, printer paper etc.
Motor driven front door, alarm for HEPA filter blockage, air flow indicator, timer for UV light, two
no. Indian standard power sockets inside the cabinet, to be provided with UV light, micro processor
controlled, pressure sensor monitoring, digital airflow verification,, interior eye level display on rear
wall,, performance factor indicator, display parameters including downflow air velocity, cabinet
malfunction, time of day, operating time of UV lights, total operating hours, time for delayed start,
hand held control for use inside cabinet eliminates glove change with all the accessories including one
additional UV light, Inner dimension: 1220 x 610 x 610 mm (L x D x H), DQ,IQ,PQ and OQ
documents should be provided, Hour meter for monitoring UV life, certificate regarding installation
Gr. A/Lab. Inst./01 Pc./01
cartoon
Gr. A/ Lab. Inst./01 Pc./02
Crate
Gr. A/ Lab. Inst./01 Pc./ 03
Crate
Gr. A/ Lab. Inst./01 Pc./04
cartoon
5.
Horizontal High pressure
Cylindrical Stem Sterilizer
(AutoclaveSemiautomatic: Single door)
6.
One chamber CO2 Incubator
with work chamber volume
approx. 300 litres
7.
8.
Refrigerator
with
data
logger (Vertical)
Horizontal Low Temp.
Freezer
(-60°C)
9.
Inverted Microscope
10.
Refrigerated
centrifuge
Micro
in govt. institutions, one year warranty plus two years additional AMC
The inner chamber, steam jacket, outer chamber and boiler are made of heavy gauge stainless steel
with leakproof argon are welding. All units are hydraulically tested upto 40 Psi, to work up to 20 Psi.
Steam boiler is fitted with water level indicator, pressure gauge, low water cutoff device and automatic
pressure control device, working chamber- Diameterx Depth 500 mm x 1200 mm, 221 litres to 235
litres.
Air jacketed heating system with temp. Control by microprocessor,Temp. Range from ambient +3 o
C to + 55 o C ,Temp. Deviation with respect to time is + 0.1K. CO 2 control by Microprocessor
based & by heat resistant Thermal Conductivity ,detector to withstand heat of decontamination
System should have built-in automatic decontamination facility to remove bacteria, fungi ,
spores ,mycoplasma etc. without removing sensor , fan or any other fitting. The system should
employ automatic decontamination routine at moist heat of 90 o C or dry heat of 180 deg C
Built-in audible and visual water level alarm should be available when the water reservoir needs
to be refilled to ensure a constant high level of humidity and to prevent cultures from drying
out. Independent electronic over temp. protection with separate sensor should be available for
sample
protection. Suitable for 230V, single phase 50Hz operation. Suitable servo voltage
stabilizer with high voltage low voltage cut off circuit, auto reset with delay timer and spike
eliminator etc. & Double stage CO2 pressure regulator with stainless steel diaphragm & 18Kg
CO2 Cylinder filled with CO2 gas 99.5% or better purity required for operation of CO 2
Incubator should also be quoted; Warranty 2 years; Optional item : Oxygen control accessory
with 3 nos. Interior gas tight split doors should be quoted.
290 – 310 liters
400 lt. capacity, with high and low alarm, to be supplied with CO2 back up system including controller
for CO2 back up with CO2 cylinder connector and all the necessary arrangements for protection
against power outrage, to be provided with voltage stabilizer, should be operated on 230 V AC,50/60
HZ with all the accessories as mentioned
Illumination LED for transmitted light, objective turret 4 position, manual, stage fixed, t be supplied
with 6 plan achromatic objectives ,4X,10X,20X,40X,50X, to be supplied with power input jack power
switch, USB port, coaxial focusing knob, Illumination wheel, freeze button, save button, with
integrated software for adjustable saturation and contrast, color temperature control, to be supplied
with all the accessories including 12.1’ high resolution color monitor with adjustable tilt, AC adaptor,,
vessel holder for 25 cm2 and 75 cm2
Table top microprocessor controlled refrigerated micro centrifuge with autoclavable 24 x 2 ml
rotor bio containment lid for superior safety for infectious materials & higher lid of the rotor
suitable to accommodates kits max speed 15000rpm with 10 rpm increment, maxRCF 21380 X g 10
g increment. Temp. Range from - 16◦C to + 40◦ C. Bright large LCD easy to read digital display for
speed, time, temp. & RCF. Maintenance free brushless motor drivee. Very fast acceleration and
Gr. A/ Lab. Inst./01 Pc./ 05
Box
Gr. A/ Lab. Inst./01 Pc./ 06
Cartoon
Gr. A/ Lab. Inst./01 Pc./07
Box
Gr. A/ Lab. Inst./01 Pc./ 08
Cartoon
Gr. A/ Lab. Inst./01 Pc./ 09
Box
Gr. A/ Lab. Inst./01 Pc./ 10
Cartoon
11.
12.
13.
14.
15.
16.
Micro Centrifuge for PCR
plate
Temperature Indicator with
alarm devices and thermal
data loggers
Manual Rotary Microtome
Ordinary Centrifuge
Machine
Tissue Homogenizer
Automatic
Microtome
Rotary
deceleration around 12 seconds or less should be available. Noise level should be less than 56
dB ( A) . Quick run / pulse run facility should be available. Should be supplied with rotor for
PCR strip tubes 8 x 8
with lid; The rotor
should be autoclavable; Power: Suitable for
220V±22 V , AC, single phase , 50 Hz/6 Hz operation; 3 Amp Warranty : 2 years. After-sales
service : Prompt & efficient after - sales service should be available from Kolkata office, to be
supplied with 24 no. adapters for 0.2 ml. micro centrifuge tubes and 24 no. adapters for 0.5 ml. micro
centrifuge tubes, Indian standard power cord and all the accessories to run the machine.
Micro centrifuge with rotor for 96 well PCR plate, fixed speed for pulse centrifuge of PCR plate
Gr. A/ Lab. Inst./01 Pc./ 11
Cartoon
Automatic (temperature ranges from 40°C and -200°C to -800°C)
Gr. A/ Lab. Inst./01 Pc./ 12
Cartoon
Imported microtome with low maintenance & backlash free micrometer feed system with cross
bearings for vertical stroke. Section thickness setting from 0.5 to 60mm, thickness increment steps of
0.5/1mm up-to 10mm, specimen retraction -220mm(approx), mechanical trimming function at two
steps(preferably 10 & 50mm), vertical specimen stroke length at least 59 mm, horizontal specimen
feed approx 28 mm, hand whell lockable in any position using two independent locking systems,
specimen orientation facility: 8 deg in X, Y, Z direction, disposable blade holder with lateral
displacement facility for complete utilization of the disposable blade edge, 100 pcs compatible
disposable blades, accessories neede to run the instrument smoothly, profile ‘C’-16 cm long knife- 2
qty., conventional knife holder should be compatible with system, kolkata based after sale service with
proven record
RPM up to 5000, Capacity 0f 18 tubes of 15 ml. capacity
Gr. A/ Lab. Inst./01 Pc./ 13
Gr. A/ Lab. Inst./01 Pc./ 14
Box
Allow homogenization of various samples derived from animal tissue, central nervous system and
peripheral tissues, e.g. tonsil, spleen, lymphoid tissue etc for TSE testing, capacity upto 24 grinding
tubes per run simultaneously in 45 seconds, 1 predefined programme intended for TSE testing 1 userdefined programme, speed: 5000-6800 rpm, run time 5-90 sec, number of cycles-1-3, display and
control panel Backlit LCD ,2lines and 16 characters long /4 button key pad, should be able to use in
Bio-safety lable-3 lab.500 samples should be homogenized per hour.
Fully Automatic Rotary Microtome should be ergonomically designed. Force compression system
should be available for effortless and uniform hand wheel rotation. Section thickness setting upto
100μm, with provision of step- by-step increment. Specimen feed approximate 25 mm(via stepper
motor) or above vertical stroke length of 70mn(+/-5%). Specimen retraction up to 90 µm or above
with 5 μm increment steps with provisions of On/ OFF. Mechanical trimming (500 μm or above)
thickness selection facility with different settings step must be available. Easy alteration should be
Gr. A/ Lab. Inst./01 Pc./ 15
Cartoon
Gr. A/ Lab. Inst./01 Pc./ 16
Box
17.
UPS 15 KVA on-line
uninterrupted Power Supply
18.
Battery for UPS- 15 KVA
on line
UPS(Uninterrupted Power
Supply)
5 KVA on line
19.
20.
21.
Battery for UPS- 5 KVA
on line
Pilot Freeze Dryer
available between trimming and reaction mode. Precise specimen orientation of 8 horizontal and
vertical direction. 2 monitorized forward and backward specimen coarse feed speeds must be available
(preferably 800 µm/s and 900 µm/s). Disposable knife holder with lateral displacement facility with
figure guard in contrasting colour. Han wheel lockable at any position with additional12 O'clock
locking by simply pulling the handle for easy changing specimen and or blade. Slot cover to protect
the interior of the instrument from sectioning debris. Spacious magnetized section waste tray for
collecting section debris .Section thickness totalizer and section counter. Max specimen size 50x 60x
40 mm. High profile blade(at least one pack of 50 blades). Sectioning speed range at least upto 400
mm/s.
UPS System should have input Power factor control & low less than 0.5% THD(1) with IGBT
rectified technology. Input Voltage: 339-438 VAC. Operating frequency:50/60 Hz.(45-65 Hz.), Input
Power factor : > 0.99 Input Current Distortion: 5% THD in normal network Condition. Normal Output
Voltage:220/230/240VAC, Single Phase. Output Voltage Regulation:+/- 2% Static, +/-5% Dynamic at
100% load change<1µs response Time, overload capacity 150% for 5 seconds/125% for 1
minute/1000% for 20µsec.(Bypass), out power factor:0.9 i.e., 15 KVA/13.5 KW, DC Bus voltage:
Must be 384 Volt, Type of Battery: Sealed Maintenance free Lead Acid Battery. Back Up time:
Minimum two hours, Minimum battery AH required: Minimum 24960 VAH & UPS should have
advanced Battery Management Features. Efficiency : 92% with rated non-linear load, graphical LCD
with Blue Black Light, 4 Led, 1 x RS 232 for local support, 2xX-slot(empty) 1x Relay contact, 1 X
emergency power off input, 2 X Environmental input.
384V, Sealed maintenance free battery compatible with 15 KVA UPS
Gr. A/ Lab. Inst./01 Pc./ 17
cartoon
Gr. A/ Lab. Inst./01 Pc./ 18
Box
On line PWM with IGBT as switching device. Input voltage range : 165 – 270 VAC. Nominal voltage
out put : 230 VAC Single phase. Out put wave form : Pure. Isolation: Out put isolation transformer
should be available as standard . DC Bass voltage must be 18 Volt. Type of battery : Sealed
maintenance free lead acid battery. Back up time : min 2 hours, Minimum battery AH required min.
11700 VAH. Gen set capability, UPS should be engine generator compatibility parameters. LCD panel
display. Multiple capabilities eliminating user gap. Out power fraction 0.08 min.
12V, 65 AH (Dry Cell); Sealed maintenance free battery UPS
Gr. A/ Lab. Inst./01 Pc./ 19
Cartoon
Gr. A/ Lab. Inst./01 Pc./ 20
Box
Shelf temp control range up to -65'C, lowest shelf temp up to -70'C,lowest condenser temp 85'C,Maximum condenser capacity 35 lt., maximum ice condensing capacity in 24 hours (L) 20,
condenser pull down from 20'c to -45'C≤25 min, shelf pull down from 20'C to -40'C ≤30 min,number
of compressors 2, refrigerant RS508B R407C, vaccum time to 100 milliTorr ≤20 min, lowest system
vacuum ≤15mT(milliTorr),aircooled system with hydraulic stoppering system and 8’ vapour port, 6
nos of freeze drying trays , 3 ml vial capacity> 2500 no., to be supplied with software and work station
with following features Software: It utilizes Programmable Logic Controller (PLC) for Windows as
per Current Good Manufacturing Practice (c GMP) standards and an Allen-Bradley Micro Logic 1500
Gr. A/ Lab. Inst./01 Pc./ 21
Crate
22.
Clean room clogs with cuffs
23.
Programmable
pump
24.
Membrane pump
25.
Ready to connect single use
peristaltic
and regulatory guidelines for computer systems used for pharmaceutical processing equipment. Up to
sixteen (16) product temperature-monitoring probes, Time, temperature and vacuum level control for
each step of the Primary and Secondary Drying phases, Up to twelve (12) Thermal Treatment
(annealing) steps, Integrated performance and vacuum integrity testing routines, Door pre seal routine,
Cascade refrigeration handling with inter stage control, Work station specification: Capacitance
manometer vacuum gauge in addition to standard Pirani vacuum gauge, Single point eutectic display,
Moisture sensor to aid in endpoint determination, Backfill to set point for highly controlled product
storage, Up to three (3) levels of security to keep the workstation safe., Pirani/ capacitance manometer
differential endpoint determination to aid in product dryness detection, Isolation valve control allowing
automated pressure rise testing during Primary Drying Extensive alarming to protect personnel, ,
product and equipment, Extensive alarming to protect personnel, product and equipment, Remote
View option allowing remote monitoring and control of the lyophilizer, Thorough historical data
trending with export function, synoptic screen for real time monitoring of the system, Local area
network (LAN)-ready., work station to be supplied with the system. Microsoft Windows based, Intel
Core 2 Duo Processor, 2 GB RAM, 500 GB Hard Disk Drive, CD/DVD Re-Writable & Floppy Disk
Drives, USB Laser jet Printer, 17-Inch Flat Screen Monitor, software along with workstation on which
the software will be installed, connecting cable between workstation and lyophilizer, 6 no. vial loading
trays with rings, one 15 KVA suitable UPS for power outrage protection, inclusive of all installation
charges, including two year warranty and one tear additional AMC, 5 lit. vacuum oil, one tube high
quality vacuum grease
Made of TPU, ideal for use in clean rooms, holes in shoe and in removable sole for better ventilation,
removable sole and detachable cuff, Autoclavable at 121°C.
To be supplied with autoclavable silicon tubing 4mm. ID 25 mt. length, Dispensing tube stainless
steel, 4 mm. internal diameter 10 cm. length, aspiration tube 4 mm. internal diameter, stainless steel,
10 cm. length, with additional autoclavable silicon tubing 8mm. ID 25 mt. length, Dispensing tube
stainless steel, 8 mm. internal diameter 10 cm. length, aspiration tube 8 mm. internal diameter,
stainless steel, 10 cm. length, one tube collar with all the accessories as mentioned, along with SS
sinker and aspiration tubes, capable of dispensing liquid from 0.5 ml. to 1 litre capacity, programmable
for timed operation or manual operation.
A self-priming diaphragm pump with an electronic speed regulator, complete with connector tubing
set. It pumps aqueous solutions quietly without stressing the product, and is equipped with an
overpressure limiter which can be set at 1-3 bar. The pump, stainless steel sinker and
tubing are resistant to 1N NaOH., max. operating pressure 3 bar (4.5 psi), preset to 2.5 bar (36.3 psi),
pump to be supplied with suitable tubing, diaphragm max 3000/min, rated output for water 650 ml/min
without pressure, 300 ml/min with filtration system, materials made of Polypropylene housing, PTFE
membrane, EPDM seals and valves, self priming up to 3 m water column, power consumption 0 .75A.
20 cm2 filter area, optimal flow path and automatic venting, surfactant free cellulose acetate
Gr. A/ Lab. Inst./01 Pc./ 22
Pack
Gr. A/ Lab. Inst./01 Pc./ 23
Cartoon
Gr. A/ Lab. Inst./01 Pc./ 24
Box
Gr. A/ Lab. Inst./01 Pc./ 25
box
filtration unit
26.
Door Interlock Switches
27.
Multichannel Pipette
28.
Multichannel Pipette
29.
Thermo cycler with three
independent blocks
30.
Automated
DNA/RNA
extraction system
31.
Portable gel
electrophoresis
system with real time
transilluminator
membrane filter with 0.2 μm pore size, Outlet side with protective filling bell, additional 100% binderfree glass fiber pre filter on the cellulose acetate membrane, luer lock as an inlet connecter, Vent ports
on the inlet side of the housing are protected against liquid passage by a hydrophobic PTFE
membrane, filtration capacity 1 ml. to max. ten lit., hold u volume before bubble point 1 ml.,
polycarbonate housing, EO sterilized, filter material PES type, filter diameter 64 mm.,
Easily and quickly to be installed, advanced design as per clean room concept, maintenance free
control panel, to be provided with manual switches for emergency mode, electromagnetic system, to
be provided with biometric reader, indicator lights and alarm buzzer, when one door is closed the
opposite door will not open
8 channel, 5-50 µl capacity should be suitable for research purpose, to be mentioned in the literature,
fully autoclavable and UV resistant,
8 channel, 50-300 µl capacity should be suitable for research purpose, to be mentioned in the
literature, fully autoclavable and UV resistant
Capable of running three different experiments simultaneously by three independently controlled
blocks, wi fi enabled and remote controlled, touch screen function for programming and running of the
instrument, 3 X 32 wells block for 0.2 ml/0.1 ml. PCR tubes/PCR plates, to be supplied with all the
accessories including PCR tubes for 500 reactions , USB drive and modem
Flexible and efficient extraction system. Completely automatic and brand, minimum twelve samples.
Suitable for wide variety of starting material, based on magnetic bead extraction technology,pre
programmed along with flexible protocols, adjustable elution volume , compatible with spin column
technology, automatic transfer of elutes into elution tubes with caps, UV lamp for decontamination of
chamber, to be supplied with all the reagents and accessories for processing of samples for extraction
of viral RNA and DNA extraction including all consumables, software, laptop, communication cables,
USB stick etc.
To be supplied with real time Transilluminator and 10 no. 1% and 10 No. 2% pre cast
agarose gels cassettes having safe blue light excitable dye, 50 bp and 1 Kb plus DNA ladder;
gel loading buffer, preprogrammed to run with gel cassettes, transilluuminator should be
provided with amber color filter, Indian power cord with universal adapter for 90-220 V,50-60 Hz,
can run minimum 4 samples at a time.
Gr. A/ Lab. Inst./01 Pc./ 26
Box
Gr. A/ Lab. Inst./01 Pc./ 27
Box
Gr. A/ Lab. Inst./01 Pc./ 28
Box
Gr. A/ Lab. Inst./01 Pc./ 29
Cartoon
Gr. A/ Lab. Inst./01 Pc./ 30
Cartoon
Gr. A/ Lab. Inst./01 Pc./ 31
Cartoon
32.
Computer controlled rapid
Microbial
Identification
system
33.
Binocular microscope
34.
Automatic Tissue Processor
35.
UV-VIS Spectrophotometer
System should be based on the technology of Advance colorimetry with a capacity to test 60 samples
at a time, System should be FDA cleared with 21 CFR part 11 compliance, System should have at least
3 optical lenses to read the color change in the reactions, System should have specific cards with
biochemical substrates impregnated for reaction, System should be useful for microbial identification
and antibiotic susceptibility testing if required with specific antibiotic panel for veterinary use, System
should be accompanied with a computer pre loaded with the system software, a densitometer,
Dispensor and 2000 tubes for sample preparation, System should have an inbuilt incubator and waste
disposal bin, System should have minimal manual steps and the card filling and loading should be
automated, System should read the reactions in both kinetic and end point mode and give results
within a day, System should be able to analyse Gram positive bacteria, Gram negative bacteria,
Bacillus species, Coryne form species, yeast species and anaerobic bacteria and 200 nos. of relevant
cards should be provided with the system, The software of the system should be pre loaded in the PC
and should be intuitive software which is easy to use, The software should have an audit trail which
would capture all the activities being done on the software, Software should have a feature to establish
a new database as per the requirement of the user apart from the already existing database, Every user
should be able to create and use their own login id and password for using the system, The vendor will
provide installation and training on site for all the trainees in the user lab, should be provided with
UPS for 30 minutes power back up, one year warranty followed by two years AMC, certificate of
installation in reputed organization should be provided by the vendor.
Illumination LED for transmitted light, objective turret 4 position, manual, stage fixed, to be supplied
with 6 plan achromatic objectives ,4X,10X,20X,40X,100X, to be supplied with power input jack,
power switch, USB port, coaxial focusing knob, Illumination wheel, freeze button, save button, with
integrated software for adjustable saturation and contrast, color temperature control, to be supplied
with all the accessories including 12.1’ high resolution color monitor with adjustable tilt, AC adaptor
Carousel type Construction with 12 station (10 reagent station, 2 wax bath) Glass containers at each
station should have capacity of 1.8 litres. Option for manual raising and rotation of carousel for
immediate tissue basket removal or transfer to the next station-using crank. Automatic reheating of
wax before basket transfer to a wax bath. standard tissue basket. Membrane keypad and LCD screen.
.Metal tissue baskets – 1 no. s capacity approx. 80 cassettes to be run at a go. Infiltration time of up to
99 hr 59 minutes & should be separately
programmable, for each station. Temperature range of wax baths 45 oC to 65 oC. Excess temperature
cut out 75 oC Both immediate and delayed start option must be available. Delayed start function up to
7 days or more. Preferably 1 minute drain time between stations for reduced carry over. Safety feature
for automatic immersion of tissue basket in a station in case of mains power failure. Power failure
indication including station number and time lapsed in excess of programmed infiltration time.
Audible alarm warning in case of error message and completion of tissue processing cycle.
Android based operating system, stand alone unit, no PC is required for running the experiments,
preloaded the programs for determination, concentration and purity of ss DNA, ds DNA, RNA, protein
Gr. A/ Lab. Inst./01 Pc./ 32
Cartoon
Gr. A/ Lab. Inst./01 Pc./ 33
Cart.
Gr. A/ Lab. Inst./01 Pc./ 34
Cart.
Gr. A/ Lab. Inst./01 Pc./ 35
Cart.
36.
Ampoule Freeze Dryer
37.
Research adjustable volume
pipettes, Autoclavable with
tip box
Research adjustable volume
pipettes, Autoclavable with
tip box
38.
39.
40.
1.
2.
3.
Research adjustable volume
pipettes, Autoclavable with
tip box
PCR Plate centrifuge
Polypropylene
bottle
Autoclavable
Rubber
stopper
for
Polypropylene bottle
Aluminum cap (20 mm
diam.),
along with unlimited number of customs assays, can be used for microvolume and cuvette based
measurements, should include a cuvette heater for providing flexibility for kinetics at temperature set
point 30-45 degree C, can measure 2.0-25000 ng/µl ds DNA and 1.0 mg/ml -750 mg/ml BSA, should
have full spectrum capabilities with wave length accuracy 1 nm, can measure sample as little as 0.5 µl,
should include built wi-fi, Ethernet and 3 USB ports, light source should be pulsed xenon flash lamp,
internal storage 8 GB flash memory, path length 10,5, 2,1 mm with accurate pathway control direction
limit 0.4 ng/ µl ds DNA maximum concentration 750 ng/ µl ds DNA (Cuvette mode), operating
voltage 12 VDC to be operated at 220 V, measurement time less than 4, one year warranty followed by
2 years AMC
Area: 0.40 Sq.m, Volume: 44.5 litres, Ice capacity: 10.5 Kg/24hrs, Ice capacity (Max): 18.0 Kg/24hrs,
condenser Ultimate low temp.: -85°C ± 5°C @ 20°C ambient, Condenser Material of Construction: SS
304, Position: Horizontal Compressor: 2 x ¾ HP, Refrigerant: CFC Free Vacuum indication: Digital
pirani vacuum gauge with a range of 999 to 1 x 10-3 mbar, Vacuum pump required: 250 Lit/min, Input
power supply: 220V, 50Hz, 1 Phase, Vacuum Pump 250 LPM, Oil Mist Filter, Spin Freezer temp 55°C ± 5°C with 5 interchangeable carriers with independent power supply and timer, 24-Port
secondary drying manifold, Spark tester, for leak check of ampoules (Imported), Hand held ampoule
sealing torch with cylinder and all the accessories for ampoule sealing
Pipette ranges 0.5-10 µl, should be certified as research category, single channel
Gr. A/ Lab. Inst./01 Pc./ 36
Crate
Gr. A/ Lab. Inst./01 Pc./ 37
Box
Pipette ranges 100-1000 µl, should be certified as research category, single channel
Gr. A/ Lab. Inst./01 Pc./ 38
Box
Pipette ranges 20-200 µl, should be certified as research category, single channel
Gr. A/ Lab. Inst./01 Pc./ 39
Box
Should be capable of centrifuging 96 wells PCR plate, fixed speed, single knob for alignment of the
plate with rotor slot, capable of sort spin
GROUP-B: LABORATORY REAGENTS & OTHER GLASS/ PLASTIC MATERIALS
Gr. A/ Lab. Inst./01 Pc./ 40
Cartoon
110 ml capacity & 20 gm weight per bottle
Gr. B/Lab. Regt./100 Pc./01
Bot.
Made of rubber for 110 ml capacity & 20 gm weight polypropylene bottle
Gr. B/Lab. Regt./100 Pc./02
Box
Aluminum cap (20 mm diam.), for 110 ml capacity & 20 gm weight polypropylene bottle
Gr. B/Lab. Regt./100 Pc./03
4.
Neutral Glass vial
3 ml. capacity, 13 mm OD, made of neutral glass, height more than 30 mm
Gr. B/Lab. Regt./360 pcs./04
box
5.
Neoprene Rubber cap for
Neutral Glass vial 3 ml.
capacity, 13 mm OD
Aluminium caps, coloured
and non colour for Neutral
Glass vial
Made of neoprene rubber, double slit, double ring, suitable for above vaccine vial, specimen to be
obtained from the respective units
Gr. B/Lab. Regt./2000 pcs./05
Pkt.
Aluminum cap for Neutral Glass vial 3 ml. capacity, caps, 13 mm. 3 ml. capacity, 13 mm OD
diameter
Gr. B/Lab. Regt./5000pcs./06
Pkt.
7.
Gel pack(Ice cold pack)
100gm
Gr. B/Lab. Regt./10 pc./07
Pkt.
8.
Syringe Filter (Membrane
filter)
Gel pack(Ice cold pack)
Tissue Culture (TC)Flask
with filter cap
Pore size-0.45 µm, sterile, individually packed- 50 pcs/pack
Gr. B/Lab. Regt./50 pc./08
Pkt.
450 gm
300 cm2, Growth area with 0.2 µm porosity filter cap, sterilized by gamma ray irradiation, legible
volume scale with white print and marking area,1360 ml.
Gr. B/Lab. Regt./10 pc./09
Gr. B/Lab. Regt./18 pc./10
Pkt.
Pkt
11.
Tissue Culture (TC)Flask
300 cm2 Growth area, sterilized by gamma ray irradiation, legible volume scale with white print and
marking area, 1360 ml.
Gr. B/Lab. Regt./18 pc./11
Pkt.
12.
500 gm
Gr. B/Lab. Regt./01 pc./12
Jar
500 gm
Gr. B/Lab. Regt./01 pc./13
Jar
AR Grade -500 ml.
Gr. B/Lab. Regt./01 pc./14
Bot
25 lt. Jar
As adjuvant for bacterial vaccine-400 ml.
Gr. B/Lab. Regt./01 pc./15
Gr. B/Lab. Regt./01 pc./16
Jar
Bot
17.
18.
Thioglycollate Broth(BQ
vaccine Media)
Standard Nutrient Broth
(HS Vaccine Media)
Formaldehyde
37%
(formalin)
Glycerol-98% Purified
Aluminum Hydroxide Gel
(3 % W/V, Liquid type)
pH-7
Yeast Extract Powder
EMEM
500 gm
1 lit., modified for autoclaving without sodium bicarbonate and L-Glutamine, contain 9.4 gm powder/
liter of media, water by Karl Fisher NMT 2.0% , glucose 9.54-11.66%, endotoxin assay NMT
1.0EU/ML at IX
Gr. B/Lab. Regt./01 pc./17
Gr. B/Lab. Regt./10 bot./18
Bot.
Pack
19.
L-Glutamine
0.292gm. /vial, sterile by gamma irradiation, to be used with EMEM
Gr. B/Lab. Regt./10 vial/19
Pack
6.
9.
10.
13.
14.
15.
16.
GROUP:C-LABORATORY KITS
1.
Classical Swine Fever
Antigen ELISA test kits
2.
M. bovis Antibody ELISA
test kit
3.
Bacillus anthracis
(common)PCR kit
4.
5.
RT PCR kit
PRRS Antibody ELISA
test kit
Bovine Herpes Virus
(BHV-1) real time PCR
kit
6.
7.
8.
9.
10.
Bovine Viral
Diarrhoea Virus
(BVD) real time RT PCR
Kit
Quantitative(q)
PCR
mastermix kit
Quantitative(q)RT
PCR master mix kit
DNA purification kit for
whole blood and tissue
11.
Viral RNA purification kit
12.
Rapid
AIV
Detection Kit
Antigen
Simple, familiar ELISA format, 96-well plates, can be fully automated for high sample throughput,
Short (less than 4-hour) or overnight protocol, to be used with tissue sample, cell culture fluid etc, ,to
be inclusive of ready-to-use reagents and bar-coded plates for safe sample identification and
traceability, to be suitable for CSFV disease detection, 5 plates/strips/ Kit
No cross-reactivity in animals infected with other mycobacterium sp., no desensitization in anergic
cattle, not required 60-day waiting period between tests, should give fast objective result with good
traceability. Can be used with standard serum and plasma samples collected for other purposes, to be
supplied/matched with a compatible software for data analysis and result interpretation, 2 hours
protocol, 5 plates/strips/ Kit
Ready to use Kit for conventional PCR(agarose gel based), should contain –ve control, +ve control,
forward and reverse primers, Taq polymerase and all other materials except agarose and TAE buffer,
100 reactions/kit
One step, For 25 reactions per pack, should support multiplex reactions.
Porcine reproductive & respiratory syndrome viral antibody ELISA test kit, 480 tests/kit, single well
format
Contains primers and probes(FAM labeled BHQ quenched) with 100 % homology with reference
sequence contained in the NCBI database, along with defined number of positive template control
with defined copy number for construction of standard curve, internal extraction control DNA,
internal extraction control primer/probe mix.
Contains primer and probe (FAM labeled BHQ quenched) against BVD virus polyprotein gene along
with template control with defined copy number for construction of standard curve to quantify the
virus, internal extraction control RNA, internal extraction control primer/probe mix .
Gr. C/Lab. Kit./1kit/1
Box
Gr. C/Lab. Kit./5kit/2
Box
Gr. C/Lab. Kit./1kit/3
Box
Gr. C/Lab. Kit./1kit/4
Gr. C/Lab. Kit./1 kit/5
Box
Box
Gr. C/Lab. Kit./150 tests/ 6
Box
Gr. C/Lab. Kit./150 tests/ 7
Box
For multiplex real time PCR reaction, for 200 reactions of reaction volume 50 µl, to be supplied with
3X1.7 ml. multiplex PCR master mix, 2 X 2 ml. nuclease free water
For multiplex real time RT PCR reaction, for 200 reactions of reaction volume 50 µl, to be supplied
with multiplex RT PCR mastermix 3 X 1.7 ml.,multiplex RT mix, Rnase free water 2 X 2 ml.
Capable of purification of DNA from animal whole blood, animal tissue, plasma, cell free fluids,
cultured cells, mouse tail, to be supplied with spin columns, tissue lysis buffer,elution buffer, washing
buffer, collection tubes, Proteinase K solution, RNAse A solution, resuspension solution,250
purification/kit
Gr.
C/Lab.
Kit./
100
Reaction/Kits/ 8
Gr.
C/Lab.
Kit./
100
Reaction/Kits/ 9
Gr. C/Lab. Kit./ 250 purification /
1 kit /10
Box
For viral RNA purification from plasma, serum and cell free body fluids, to be supplied with mini
spin columns, carrier RNA, buffers and collection tubes, 50 purification/kit
30 tests/pack
Gr. C/Lab. Kit./ 50 purification
/1kits/11
Gr. C/Lab. Kit /30 tests/pack/12
Box
Box
Box
Box
13.
14.
15.
16.
17.
18.
IBD Virus Antigen Test
Kit
NDV ELISA Kit (Ab.
Detection)
Rapid IBD test kit
Rapid NDV Antigen Test
kit
Sandwitch ELISA test Kit
for BSE Purification of
PrPsc.
Avian Influenza Virus
subtype (H5) Real time
kits
19.
Avian Influenza Virus
subtype (H7) Real time
kits
20.
Avian Influenza Virus
subtype (H9) Real time
kits
21.
AIV Antibody ELISA Kit
22.
Rapid
AIV
subtype
H5Antigen detection kit
Avian Influenza Virus
subtype (H5) Antibody
detection kit
Avian Influenza Virus
subtype (H7) Antibody
detection kit
Newcastle Disease (ND)
Virus Real time kits
23.
24.
25.
Gr. C/Lab. Kit /10 tests/kit/13
Box
Gr. C/Lab. Kit /480 tests/pack/14
Box
Gr. C/Lab. Kit /10 tests/pack/15
Box
Gr. C/Lab. Kit /10 tests/pack/16
Box
192 tests/kit i) TeSeETM Purification Kit - 192 test sii) Calibration Syringe & Needle (X100) iii)
Calibration Syringe & Needle (X100) Detection Kit: TeSeE Detection kit (192 tests) Bovine
Sampling Syringe.
For Haemaglutinin H5 gene, H5 specific primer/probe mix (150 reactions)FAM labeled BHQ
quenched, H5 positive control template, Internal extraction control RNA, Internal extraction control
primer/probe mix (150 reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions)
FAM labeled, BHQ quenched, RNAse/DNAse free water,
For Haemaglutinin H7 gene, H7 specific primer/probe mix (150 reactions)FAM labeled BHQ
quenched, H7 positive control template, Internal extraction control RNA, Internal extraction control
primer/probe mix (150 reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions)
FAM labeled, BHQ quenched, RNAse/DNAse free water,
For Haemaglutinin H9 gene, H9 specific primer/probe mix (150 reactions)FAM labeled BHQ
quenched, H9 positive control template, Internal extraction control RNA, Internal extraction control
primer/probe mix (150 reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions)
FAM labeled, BHQ quenched, RNAse/DNAse free water,
Competitive ELISA Kit for qualitative detection of antibody to the most common and prevalent AIV
in chicken , duck turkey, quail, goose, guinea partridge, red partridge, pheasant, swan, horse/swine
samples 480 Test /Kit
25 test/kit
Gr. C/Lab. Kit /192 tests/Kit/17
Box
Gr. C/Lab. Kit /150 tests/pack/18
Box
Gr. C/Lab. Kit /150 tests/pack/19
Box
Gr. C/Lab. Kit / 150 test /Kit/20
Box
Gr. C/Lab. Kit / 480 test /Kit/21
Box
Gr. C/Lab. Kit / 25 test /Kit/22
Box
192 test /Kit
Gr. C/Lab. Kit / 192 test /Kit /23
Box
192 test /Kit
Gr. C/Lab. Kit t/ 192 test /Kit/24
Box
For M gene, NDV specific primer/probe mix (150 reactions)FAM labeled BHQ quenched, NDV
positive control template, Internal extraction control RNA, Internal extraction control primer/probe
mix (150 reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions) FAM labeled,
BHQ quenched, RNAse/DNAse free water, For rapid and validated diagnosis of the subtype, 150
Gr. C/Lab. Kit /150 tests/pack/25
Box
10 tests/kit
480 tests/kit
10 tests/pack
10 tests/pack
26.
Avian
Bronchitis
Time Kits
27.
Avian
Adenovirus(Egg
Drop Syndrome)
28.
Mycoplasma gallisepticum
Real Time Kits
29.
Brucella genus Real Time
kits
30.
Camylobacter foetus Real
Time Kits
31.
Salmonella detection PCR
kits
E coli 0157:H7 detection
PCR kit
SYBR Green I PCR kits
32.
33.
1.
Infectious
Virus, Real
2.
Basic synthesis(Per base
charges) for Primers
Probe
3.
Probe
tests/pack
For IBV specific primers and probes (150 reactions)FAM labeled BHQ quenched, IBV positive
control template, Internal extraction control RNA, Internal extraction control primer/probe mix (150
reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions) FAM labeled, BHQ
quenched, RNAse/DNAse free water,
For EDS specific primers and probes (150 reactions)FAM labeled BHQ quenched, EDS positive
control template, Internal extraction control DNA, Internal extraction control primer/probe mix (150
reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions) FAM labeled, BHQ
quenched, RNAse/DNAse free water,
For M.gallisepticum specific primers and probes (150 reactions)FAM labeled BHQ quenched, EDS
positive control template, Internal extraction control DNA, Internal extraction control primer/probe
mix (150 reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions) FAM labeled,
BHQ quenched, RNAse/DNAse free water,
Brucella spp. specific primer/probe mix (150 reactions)FAM labeled BHQ quenched, Brucella spp.
positive control template, Internal extraction control DNA, Internal extraction control primer/probe
mix (150 reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions) FAM labeled,
BHQ quenched, RNAse/DNAse free water,
C. foetus specific primer/probe mix (150 reactions) FAM labeled BHQ quenched, C. foetus. positive
control template, Internal extraction control DNA, Internal extraction control primer/probe mix (150
reactions) VIC labeled, Endogenous ACTB primer/probe mix (150 reactions) FAM labeled, BHQ
quenched, RNAse/DNAse free water,
Semi quantitative25 runs/kit
PCR kit & primer mix-1 box25 reactions/kit
2x SYBR Green PCR Master Mix, Hot Start Taq DNA Polymerase, SYBR Green PCR Buffer, dNTP
mix, including dUTP, SYBR Green I, 5 mM MgCl2 , 200 runs X 50µl, For Real time assay using
SYBR green I dye, 200 runs X 50µl,
Gr. D-LABORATORY MOLECULAR REAGENTS
HPLC purified, salt free oligos, length restriction (mer) 5-49, synthesis scale tube 0.03µmole (30nm),
to be supplied positively within 15 working days, per base charges to be included.
Reporter dye – FAM/VIC/HEX/Cy5; Quencher dye – BBQ; Condition: TMA 1.0 OD, HPLC purified.
Lyophilized. Rate should be quoted per base pair. Charges for any LNA have to be quoted separately.
Amount and concentration of the reagent has to be quoted.
Reporter dye – FAM/VIC/HEX/Cy5; Quencher dye – BHQ 1; Condition: TMA 1.0 OD, HPLC
purified. Lyophilized. Rate should be quoted per base pair. Charges for any LNA have to be quoted
separately. Amount and concentration of the reagent has to be quoted.
Gr. C/Lab. Kit /150 tests/pack/26
Box
Gr. C/Lab. Kit /150 tests/pack/27
Box
Gr. C/Lab. Kit /150 tests/pack/28
Box
Gr. C/Lab. Kit /150 tests/pack
/29
Box
Gr. C/Lab. Kit /150 tests/pack/30
Box
Gr. C/Lab. Kit /25 runs/kit/31
Box
Gr. C/Lab. Kit /25reactions/kit/32
Box
Box
Gr. C/Lab. Kit /200 runs/33
Gr. D/Lab. Regt./1 vial/1
Cartoon
Gr. D/Lab. Regt./1vial/2
Cartoon
Gr. D/Lab. Regt./1 vial /3
Cartoon
4.
Primer, forward
5.
Primer, Reverse
Synthesis scale tube 0.03 micro molar, length restriction 5- 40 (Mer), minimum yield OD 3.0, rate to
be quoted price per base, High prity salt free
Synthesis scale tube 0.03 micro molar, length restriction 5- 40 (Mer), minimum yield OD 3.0, rate to
be quoted price per base, High prity salt free
Gr. D/Lab. Regt./ 1 vial /4
Cartoon
Gr. D/Lab. Regt./1 vial/5
Cartoon
Sd/(Dr. S. Bose)
Director of Animal Husbandry &
Veterinary Services, West Bengal
Download