Capacitance, Phase & Earth Ground Testers
Capacitance Meters
Phase Testers
• Measure 0.1 pF to 20,000 µF in nine selectable ranges
• Accuracy ± 0.5 % typically
• Zero adjustment ± 20 pF
• Fuse-protected against charged capacitors
• 3 1/2 digits readout
• Overload/out of range indication
• Complete with test alligator clips, spare 200 mA fuse and 9 V battery
• Capacitance Range: 200 pF, 2 nF, 20 nF, 200 nF, 2 µF, 20 µF, 200 µF, 2000 µF, 20 000 µF
• Testing phase orientation of 3-phase power sources ranging from 100 to 660 VAC
• Frequency range over 50 to 70 Hz
• Five LEDs indicate phase orientation (clockwise or counter-clockwise); and whether each of three phases is live
• Complete with three large alligator clips
HX164
Model HX164
Model HX165
Model No.
HF969
Pantone 534 Blue
Pantone 123 Yellow
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 123 Yellow
Mfg. No.
Description
K5020Pantone 534 Blue Capacitance Meter
Cable Tracers
Black
Blue - 100/80/30/5
Price/Each
159.00
Rich Black 20/20/20/100
• All components are fully fuse Pantone 534 Blue - 100/80/30/5
protected
and intrinsically safe; Only if you REALLY need them:
Pantone
485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
and fit into a foam-lined carrying case
• Model R2000 Receiver has two detectors in its tip which are tuned to pick up the electromagnetic signals ('short' mode) or electrostatic signals ('open' mode) generated by other components
• LEDs and sensitivity settings indicate the relative signal strength to allow easy detection of the signal source
• Model S2600 Load Signal Generator, when connected to an energized line, will draw a rapidly fluctuating current pulse from the source, causing the power line to emit an electromagnetic signal which is detected by the R2000 in the 'short' mode
• Model T2200 Transmitter injects a signal into an unenergized conductor. If the conductor is broken (open), no current will flow, so the signal is present as a voltage pulse, which is detected along the conductor's length by the R2000's electrostatic detector ('open' mode)
• Model A2201 Inductive Clamp when clamped around the energized line and plugged into the T2200 will induce a signal onto the downstream (load) side to enable identification of equipment on that circuit
• Includes: Receiver, load signal generator, transmitter, clamp-on transmitter accessory, cordsets and adapter
Model No.
HD909
Mfg. No.
AT-2004
Description
Price/Each
Cable Tracing System1495.00
• Combines above 3-phase tester with a motor rotation tester for measuring the rotation direction of motor shafts
• Ensures motor is not damaged from incorrect wiring
• Complete with three large alligator clips
HX165
Model No.
HX164
HX165
Pantone 534 Blue
Pantone 123 Yellow
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Red - 10/100/100/5
Black
Rich Black 20/20/20/100
Yellow - 0/27/100/0
Pantone 123 Yellow
Mfg. No.
Description
RT-606Pantone 534 Blue 3-Phase Rotation Tester Blue - 100/80/30/5
RT-608
3-Phase and Motor Rotation Tester
Price/Each
79.00
149.00
Phase Rotation Indicators
Pantone 534 Blue
- 100/80/30/5
with
open
phase checker
Pantone 485 Red - 10/100/100/5
Only if you REALLY need them:
123 Yellow - 0/27/100/
•Pantone
Designed
to check the presence of an open phase and also the phase sequence with rotating disks and lamps
• Verifies a wide range of 3-phase power sources from 110 V to 600 V
• Colour-coded integrated test leads eliminate the risk of misconnection and meter damage
Model No.
IA185
Mfg. No.
KEW8031
Description
Phase Rotation Indicator
Price/Each
103.00
Phase Rotation Indicators
this book is
printed on
80% recycled
paper!
1-800-661-2400
www.tenaquip.com
1806
www.tenaquip.com Model No.
IA250
Mfg. No.
9040
Description
Phase Rotation Indicator
1-800-661-2400
Price/Each
346.00
29484E
2012 © Tenaquip Limited
Did you know...
• A portable handheld instrument designed to detect the rotary field of three-phase systems
• With three test leads, this rugged tester easily determines a clockwise or counter-clockwise direction
• Large display to easily determine field rotation
• Ideal when connecting induction motors, replacing transformers and paralleling generators
• Nominal voltage from 40 V to 690 V AC
• Frequency range (fn) from 15 to 400 Hz
• Current pickup is 1 mA
• Nominal test current (in per phase) is 1 mA
• Cat. III 600 V safety rating
• Covered by a 2-year warranty
• Includes three test leads and probes, alligator clips and a user's manual