Color profile: Generic offset separations profile Black 133 lpi at 45 degrees ZONE PROGRAMMING DLS DOWNLOADING Op Def 29007177R002 STANDARD / CP-01(SIA FAR) Digital Security Controls Toronto, Canada www.dsc.com Printed in Canada PC1616/PC1832/PC1864 v4.1 PROGRAMMING WORKSHEET 8 32 (3xPC5108) 32 (PC5132) 2 8 4 6 16 (1xPC5108) 16 (RF5108) 2 8 2 1 Answering Machine/Double Call Enabled 2 User Can Enable DLS Window OFF User Can NOT Enable DLS Window PC1832 183200 Enter 6 Hexadecimal Digits Zone Attributes Enabled ‘S’ SIA FAR (CP-01) Only Enter 6 Hexadecimal Digits Enabled ‘’ Call Back Disabled User Initiated Call Up Enabled User Initiated Call Up Disabled 5 Auto Event Buffer Upload Enabled Auto Event Buffer Upload Disabled 6 Future Use 8 Future Use ZONE Definition Panel ID Code [404] Enter 6 Hexadecimal Digits Call Back Enabled Downloading Access Code [403] PC1616 161600 4 Future Use Def Answering Machine/Double Call Disabled 3 7 Panel PC1864 186400 [405] Answering Machine Double Call Timer Def 060 [406] Number of Rings to Answer On 1 Audible 2 Steady 3 Chime 4 Bypass 5 Force Arm 6 Swinger 7 TX Delay 8 Wireless Zn 9 Cross Zone (001-255) Seconds (001-255) Rings Def 000 [499] Initiate PC-Link Downloading Enter [499][Installer’s Code][499] [402] DLS Downloading Telephone Number (32 Digits) D This Programming Worksheet provides all programming sections and default values for the PowerSeries PC1616, PC1832 and PC1864. This programming worksheet shall be used in conjunction with the PowerSeries PC1616, PC1832 and PC1864 Reference Manual which can be obtained from your local dealer or downloaded from the DSC website at www.dsc.com. The Reference Manual provides a detailed description of each programming option. Programming Options for the PC1616/PC1832/PC1864 are identical except for the number of Zones, Partitions and On-board PGMs. Refer to the table below for available options for each model. PC1616 PC1832 PC1864 On-board Zones Hardwired Zones Wireless Zones On-board PGMs Keypads Partitions Downloading Option Codes [401] ON 8 64 (7xPC5108) 32 (PC5132) 4 8 8 How to Program: DSC recommends filling in the Programming Worksheet with the required programming information before programming the system. This will reduce the time required to program and will help eliminate errors. ZN# SPECIAL INSTALLER FUNCTIONS NOTE: Programming Toggle Options: Enter the 3-digit programming section number. The Armed light will turn OFF and the Ready light will turn ON. The keypad will display toggle option status as indicated below: Keypad Type LED Fixed-Message LCD Programmable-Message LCD OptionON Zone Light ON Indicator # ON # Displayed Option OFF Zone Light OFF Indicator # OFF Dash [-] Displayed To toggle an option ON or OFF, press the corresponding number on the keypad. The change will be displayed. When all the toggle options are configured as required: Press the [#] key to exit the programming section. The Ready light will turn OFF and the Armed light will turn ON. NOTE: If the panel is a local system, press [#] to skip this step. NOTE:In addition to the standard digits 0-9, HEX digits can also be programmed in the phone number if required. HEX [A] Not Supported HEX [B] Simulated [,] key Press [,][2][,] HEX [C] Simulated [#] key Press [,][3][,] HEX [D] Dial tone search Press [,][4][,] HEX [E] Two second pause Press [,][5][,] Programming Decimal and Hexadecimal (HEX) Data: Decimal: Enter the 3-digit programming section number. The Armed light will turn OFF and The Ready light will turn ON. Enter the data recorded in the Programming Worksheet For sections that require multiple 2 or 3 digit numbers, the keypad will double-beep after each 2 or 3 digit entry before moving to the next item on the list. After the last digit in the section is entered, the keypad will beep rapidly 5 times and exit the program section. The Ready light will turn OFF and the Armed light will turn ON. For sections that do not require data for every box (such as phone numbers) press the [#] key to exit the programming section after entering all of the required data. The Ready light will turn OFF and the Armed light will turn ON. Enter [#] at any time to exit a programming section and save programming changes. Hexadecimal: To enter a HEX digit, press the [,] key to begin HEX programming. The Ready light will FLASH. Refer to the chart below and press the number corresponding to the HEX digit required. The Ready light will continue to FLASH. Press [,] again to return to normal decimal programming. The Ready light will turn ON. HEX [A] HEX [B] [,] [1] [,] [,] [2] [,] HEX [C] HEX [D] [,] [3] [,] [,] [4] [,] HEX [E] HEX [F] [,] [5] [,] [,] [6] [,] How to Exit Installer Programming: To exit installer programming, press the [#] key when the panel is waiting for a 3-digit section number (the Armed light is ON). Viewing Programming LED and LCD5501Z Keypads All programming sections can be viewed from an LED or LCD5501Z keypad. When a programming section is entered, the keypad will immediately display the first digit of information programmed in that section. The keypad displays the information using the binary format, indicated below: See Hex data entry instructions Value Zone 1 Zone 2 Zone 3 Zone 4 Zone Light OFF Zone Light ON Use the arrow keys (< >) or press any of the Emergency keys (Fire, Auxiliary or Panic) to advance to the next digit. When all the digits in a section have been viewed, the panel will exit the section: the Ready light will turn OFF, and the Armed light will turn ON, The system will wait for the next three-digit programming section number to be entered. Press the [#] key to exit the section LCD Keypads When a programming section is entered, the keypad will display all the information programmed in that section. Use the arrow keys (< >) to scroll through the data being displayed. To exit the section, scroll past the end of the data displayed, or press the [#] key. H:\PowerSeries[NEW]\PWS\29007177R001_PWS_Released.cdr Wednesday, March 08, 2006 1:40:10 PM Plate: 1 of 4 ZONE Definition 9 13 14 15 16 17 18 19 20 21 22 23 24 25 S S S S S S S S S S S S S S PC1864/PC1832 support 32 wireless zones, PC1616 supports 16 wireless zones RECORD ZONE LABEL HERE if APPLICABLE (Refer to Keypad Installation Manual) ZONE TYPE 1 ZONE ATTRIBUTES 2 3 4 5 6 7 8 9 b 1 Gasb 24Hr 24Hr Heatingb 24Hr Auxiliary/Medical 24Hr Panicb 24Hr Emergencyb 24Hr Sprinklerb 24Hr Waterb 24Hr Freezeb 24Hr Latching Tamperb Momentary Keyswitch Armb Maintained Keyswitch Armb Not Used Interior Delayb 1 S S S S S S S S S S S S S S S S S S ZONE Definition 9 26 29 30 31 32 33 34 35 36 37 87 88 Denotes burglary applications only [804][01-32] SERIAL # (Wireless) ZONE ATTRIBUTES 2 3 4 5 6 7 8 2 f S 1 ZONE ATTRIBUTES 2 3 4 5 6 7 8 24Hr Non-alarm Auto Verified Fire Fire Supervisory Day Zoneb Instant Stay/Away Future Use Future Use 24Hr Bell/Buzzer Future Use Night Zone Delay 24Hr Fire (Wireless)f Standard 24Hr Fire (Wireless)f S S S S Denotes residential fire applications only PARTITION ASSIGNMENT 3 4 5 6 7 8 ALARM ZONE REPORTING CODES (Def FF) ALARM REST TAMPER TAMP REST [990] Installer Lockout Enable Enter [990][Installer’s Code][990] 1 [001] 0 1 [101] [202] [210] [218] [226] [234] [242] [250] [258] [320] [324] [330] [334] [901] Installer Walk Test Mode Enable/Disable Enter [,][8][Installer’s Code][901] [991] Installer Lockout Disable Enter [991][Installer’s Code][991] 2 [001] 0 3 [102] [202] [210] [218] [226] [234] [242] [250] [258] [320] [324] [330] [334] Enter [,][8][Installer’s Code][902] [902] Module Supervision Reset Enter [,][8][Installer’s Code][903] [903] Module Supervision Field Enter [,][8][Installer’s Code][904] [904] Wireless Module Placement Test [905] Future Use Enter [,][8][Installer’s Code][906] [906] Local Test of Downlook Remote Trigger [992] Future Use 3 [001] 0 3 [103] [202] [210] [218] [226] [234] [242] [250] [258] [320] [324] [330] [334] [993] Restore Alternate Communicator to Default Programming 4 [001] 0 3 [104] [202] [210] [218] [226] [234] [242] [250] [258] [320] [324] [330] [334] Enter [993][Installer’s Code][993] [994] Future Use 5 [001] 0 4 [105] [202] [210] [218] [226] [234] [242] [250] [258] [320] [324] [330] [334] [995] Restore Escort5580 to Default Programming 6 [001] 0 4 [106] [202] [210] [218] [226] [234] [242] [250] [258] [320] [324] [330] [334] Enter [995][Installer’s Code][995] [996] Restore PC5132 to Default Programming Enter [996][Installer’s Code][996] 7 [001] 0 4 [107] [202] [210] [218] [226] [234] [242] [250] [258] [320] [324] [330] [334] 8 [001] 0 4 [108] [202] [210] [218] [226] [234] [242] [250] [258] [320] [324] [330] [334] [907] Future Use [997] Restore PC5400 to Default Programming Enter [997][Installer’s Code][997] [908] Future Use [998] Restore PC5936 to Default Programming Enter [998][Installer’s Code][998] 9 [001] 0 0 [109] [203] [211] [219] [227] [235] [243] [251] [259] [320] [324] [330] [334] Enter [999][Installer’s Code][999] 10 [001] 0 0 [110] [203] [211] [219] [227] [235] [243] [251] [259] [320] [324] [330] [334] 11 [001] 0 0 [111] [203] [211] [219] [227] [235] [243] [251] [259] [320] [324] [330] [334] 12 [001] 0 0 [112] [203] [211] [219] [227] [235] [243] [251] [259] [320] [324] [330] [334] 13 [001] 0 0 [113] [203] [211] [219] [227] [235] [243] [251] [259] [320] [324] [330] [334] 14 [001] 0 0 [114] [203] [211] [219] [227] [235] [243] [251] [259] [320] [324] [330] [334] 15 [001] 0 0 [115] [203] [211] [219] [227] [235] [243] [251] [259] [320] [324] [330] [334] 16 [001] 0 0 [116] [203] [211] [219] [227] [235] [243] [251] [259] [320] [324] [330] [334] 17 [002] 0 0 [117] [204] [212] [220] [228] [236] [244] [252] [260] [321] [325] [331] [335] 18 [002] 0 0 [118] [204] [212] [220] [228] [236] [244] [252] [260] [321] [325] [331] [335] 19 [002] 0 0 [119] [204] [212] [220] [228] [236] [244] [252] [260] [321] [325] [331] [335] [909] Future Use [999] Restore PC1616/1832/1864 to Default Programming Wireless Placement Test Indications (Refer to PC5132 Installation Manual) Select module/transmitter (zones 01-32). Press [#] to cancel PLACEMENT Good Bad LED KEYPAD LED 1 ON Steady LED 3 ON Steady LCD KEYPAD “GOOD” “BAD” Downlook Remote Trigger Test Enter [01] to select Telephone #1 via land line BELL/BUZZER 1 Beep / Squawk 3 Beeps / Squawks Enter [02] to select Telephone #2 via land line KEYPAD PROGRAMMING NOTE: Must be performed at each KEYPAD requiring programming [0] Slot address (Valid Entries 0-8 for Partition, 1-8 for Slot) [1]-[05] Function Key Assignment (Valid Entries 0-32) LCD 5501/LED Defaults FUNCTION KEY OPTIONS 00 01 02 03 04 05 06 07 08 09 10 Not Used Select Partition 1 Select Partition 2 Stay Arm Away Arm [,][9] No-Entry Arm [,][4] Chime ON/OFF [,][6][----][4] System Test [,][1] Bypass Mode [,][2] Trouble Display [,][3] Alarm Memory LCD Defaults 11 12 13 14 15 16 17 18 19 20 21 [,][5] Access Code Programming [,][6] User Functions Command Output #1 [,][7][1] Command Output #2 [,][7][2] Sensor Reset General Voice Prompted Help [,][0] Quick Exit [,][1] Reactivate Stay/Away Zones Identified Voice Prompted Help Command Output #3 [,][7][3] Future Use Command Output #4 [,][7][4] 22 23 24 25 26 27 28 29 30 31 32 KEYPAD 1 Active Camera Monitior Selection Bypass Recall Recall Bypass Group Future Use Time of Day Programming Select Partition 3 Select Partition 4 Select Partition 5 Select Partition 6 Select Partition 7 Select Partition 8 KEYPAD 2 KEYPAD 3 KEYPAD 4 KEYPAD 5 KEYPAD 6 KEYPAD 7 KEYPAD 8 Partition/ [020] Zone Slot Assigned 1 1 1 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 20 [002] 0 0 [120] [204] [212] [220] [228] [236] [244] [252] [260] [321] [325] [331] [335] 0 3 0 3 0 4 0 4 0 6 0 6 1 4 1 4 1 6 1 6 21 [002] 0 0 [121] [204] [212] [220] [228] [236] [244] [252] [260] [321] [325] [331] [335] 22 [002] 0 0 [122] [204] [212] [220] [228] [236] [244] [252] [260] [321] [325] [331] [335] 23 [002] 0 0 [123] [204] [212] [220] [228] [236] [244] [252] [260] [321] [325] [331] [335] 24 [002] 0 0 [124] [204] [212] [220] [228] [236] [244] [252] [260] [321] [325] [331] [335] 25 [002] 0 0 [125] [205] [213] [221] [229] [237] [245] [253] [261] [321] [325] [331] [335] 26 [002] 0 0 [126] [205] [213] [221] [229] [237] [245] [253] [261] [321] [325] [331] [335] 27 [002] 0 0 [127] [205] [213] [221] [229] [237] [245] [253] [261] [321] [325] [331] [335] PGM PROGRAMMING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Residential Burglary & Fire Bell Output Future Use Sensor Reset [,][7][2] 2-wire Smoke Support (PGM 2 only) System Armed Status Ready to Arm Keypad Buzzer Follow Mode Courtesy Pulse System Trouble Output (with Trouble options) System Event Strobe (with Event options) System Tamper (all sources: zones, keypad, modules) TLM and Alarm Kissoff Output Ground Start Pulse Remote Operation (DLS Support) Future Use PGM OPTIONS [009] PGM 1 [009] PGM 2 [010] PGM 3 [010] PGM 4 [010] PGM 5 [010] PGM 6 [010] PGM 7 [010] PGM 8 [010] PGM 9 [010] PGM 10 [011] PGM 11 [011] PGM 12 [011] PGM 13 [011] PGM 14 1 Def 19 Def 10 Def 01 Def 01 Def 01 Def 01 Def 01 Def 01 Def 01 Def 01 Def 01 Def 01 Def 01 Def 01 PGM ATTRIBUTES 1 2 3 4 5 6 7 8 PGM ATTRIBUTES 1 2 3 4 5 6 7 8 PGM OUTPUT OPTIONS Main Panel Main Panel Main Panel & PC5208 Main Panel & PC5208 PC5208 PC5208 PC5208 PC5208 PC5208 PC5208 PC5204 PC5204 PC5204 PC5204 [501] [502] [503] [504] [505] [506] [507] [508] [509] [510] [511] [512] [513] [514] 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Away Armed Status Stay Armed Status Command Output #1 [,][7][1] Command Output #2 [,][7][2] Command Output #3 [,][7][3] Command Output #4 [,][7][4] 24-Hr Silent Input 24-Hr Audible Input Delayed Fire & Burglary Output Future Use Future Use Future Use Zone Follower Partition Status Alarm Memory Future Use Future Use PGM ATTRIBUTES 2 3 4 5 6 7 PGM ATTRIBUTES (Definitions) 1 Used only on OPT 9 (Service Req'd) and OPT 10 (Burglar Event) 2 Used only on OPT 9 (AC Fail) and OPT 10 (Fire Event) 3 True Output (enabled) Inverted Output (Off) OPT 9 (TLM Fault) and OPT 10 (Panic Event) 4 Follows Timer (enabled) None (Disabled) OPT 9 (FTC) and OPT 10 (Medical Event) 5 Code Req'd (enabled) No Code Req'd (disabled) OPT 9 (Zone Fault) and OPT 10 (Supervisory Event) 6 Used only on OPT 9 (Zone Tamper) and OPT 10 (Priority Event) 7 Used only on OPT 9 (Zone Low Battery) and OPT 10 (Holdup Event) 8 Used only on OPT 9 (Loss of Clock) and OPT 10 (Follows Timer) NOTE: If attribute 8 is ON, attributes 1-7 must also be turned ON) PGM PARTITION ASSIGNMENT 1 2 3 4 5 6 7 8 [551] [552] [553] [554] [555] [556] [557] [558] [559] [560] [561] [562] [563] [564] 8 NOTES Output Types [03] and [020] can NOT be used together on the same system PC 1616 has 2 On-board PGMs PC 1832 has 2 On-board PGMs PC 1864 has 4 On-board PGMs 9 b Enter [,][8][Installer’s Code][900] [000] KEYPAD ENROLLMENT You cannot enter installer programming while any aprtition is armed or in alarm. Null Zone (Not Used) Delay 1b Delay 2b Instantb Interiorb Interior, Stay/Awayb Delay, Stay/Awayb Delayed 24Hr Fire Hardwiredf Standard 24Hr Fire Hardwired 24Hr Supervisory 24Hr Supervisory Buzzerb 24Hr Burglaryb 24Hr Holdupb ZONE ATTRIBUTES 2 3 4 5 6 7 8 [900] Panel Version Displayed An error tone indicates the installer code entered is incorrect,Press [#] to clear the entry then reenter the installer code. The Armed and Ready lights indicate programming status: Panel waiting for 3-digit section number Panel waiting for data to be entered Panel waiting for HEX data to be entered Silent Pulsed None None None None No Delay Hardwired None NOTES: Keypads are required for 24Hr buzzer zone, To enter Installer Programming press [,][8][555555].The Program light will FLASH on LED Keypads The display will change to ‘Enter Section’ on the LCD keypad. Armed Light ON Ready Light ON Ready Light FLASHING Disabled 00 01 02 03 04 05 06 07 08 09 10 11 12 1 28 [002] 0 0 [128] [205] [213] [221] [229] [237] [245] [253] [261] [321] [325] [331] [335] 29 [002] 0 0 [129] [205] [213] [221] [229] [237] [245] [253] [261] [321] [325] [331] [335] 30 [002] 0 0 [130] [205] [213] [221] [229] [237] [245] [253] [261] [321] [325] [331] [335] 31 [002] 0 0 [131] [205] [213] [221] [229] [237] [245] [253] [261] [321] [325] [331] [335] 32 [002] 0 0 [132] [205] [213] [221] [229] [237] [245] [253] [261] [321] [325] [331] [335] 33 [003] 0 0 [133] [206] [214] [222] [230] [238] [246] [254] [262] [322] [326] [332] [336] 34 [003] 0 0 [134] [206] [214] [222] [230] [238] [246] [254] [262] [322] [326] [332] [336] 35 [003] 0 0 [135] [206] [214] [222] [230] [238] [246] [254] [262] [322] [326] [332] [336] 36 [003] 0 0 [136] [206] [214] [222] [230] [238] [246] [254] [262] [322] [326] [332] [336] 37 [003] 0 0 [137] [206] [214] [222] [230] [238] [246] [254] [262] [322] [326] [332] [336] 38 [003] 0 0 [138] [206] [214] [222] [230] [238] [246] [254] [262] [322] [326] [332] [336] 39 [003] 0 0 [139] [206] [214] [222] [230] [238] [246] [254] [262] [322] [326] [332] [336] 40 [003] 0 0 [140] [206] [214] [222] [230] [238] [246] [254] [262] [322] [326] [332] [336] 41 [003] 0 0 [141] [207] [215] [223] [231] [239] [247] [255] [263] [322] [326] [332] [336] 42 [003] 0 0 [142] [207] [215] [223] [231] [239] [247] [255] [263] [322] [326] [332] [336] 43 [003] 0 0 [143] [207] [215] [223] [231] [239] [247] [255] [263] [322] [326] [332] [336] 44 [003] 0 0 [144] [207] [215] [223] [231] [239] [247] [255] [263] [322] [326] [332] [336] 45 [003] 0 0 [145] [207] [215] [223] [231] [239] [247] [255] [263] [322] [326] [332] [336] 46 [003] 0 0 [146] [207] [215] [223] [231] [239] [247] [255] [263] [322] [326] [332] [336] 47 [003] 0 0 [147] [207] [215] [223] [231] [239] [247] [255] [263] [322] [326] [332] [336] 48 [003] 0 0 [148] [207] [215] [223] [231] [239] [247] [255] [263] [322] [326] [332] [336] 49 [004] 0 0 [149] [208] [216] [224] [232] [240] [248] [256] [264] [323] [327] [333] [337] 50 [004] 0 0 [150] [208] [216] [224] [232] [240] [248] [256] [264] [323] [327] [333] [337] 51 [004] 0 0 [151] [208] [216] [224] [232] [240] [248] [256] [264] [323] [327] [333] [337] 52 [004] 0 0 [152] [208] [216] [224] [232] [240] [248] [256] [264] [323] [327] [333] [337] 53 [004] 0 0 [153] [208] [216] [224] [232] [240] [248] [256] [264] [323] [327] [333] [337] 54 [004] 0 0 [154] [208] [216] [224] [232] [240] [248] [256] [264] [323] [327] [333] [337] 55 [004] 0 0 [155] [208] [216] [224] [232] [240] [248] [256] [264] [323] [327] [333] [337] 56 [004] 0 0 [156] [208] [216] [224] [232] [240] [248] [256] [264] [323] [327] [333] [337] 57 [004] 0 0 [157] [209] [217] [225] [233] [241] [249] [257] [265] [323] [327] [333] [337] 58 [004] 0 0 [158] [209] [217] [225] [233] [241] [249] [257] [265] [323] [327] [333] [337] 59 [004] 0 0 [159] [209] [217] [225] [233] [241] [249] [257] [265] [323] [327] [333] [337] 60 [004] 0 0 [160] [209] [217] [225] [233] [241] [249] [257] [265] [323] [327] [333] [337] 61 [004] 0 0 [161] [209] [217] [225] [233] [241] [249] [257] [265] [323] [327] [333] [337] 62 [004] 0 0 [162] [209] [217] [225] [233] [241] [249] [257] [265] [323] [327] [333] [337] 63 [004] 0 0 [163] [209] [217] [225] [233] [241] [249] [257] [265] [323] [327] [333] [337] 64 [004] 0 0 [164] [209] [217] [225] [233] [241] [249] [257] [265] [323] [327] [333] [337] 100 95 75 25 5 0 Color profile: Generic offset separations profile Black 133 lpi at 45 degrees COMMUNICATOR CALL DIRECTIONS PARTITION PROGRAMMING [201] Partition Select Mask Entry Delay 1 Entry Delay 2 AUTO-ARM TIMES Exit Delay Sun Mon Tue Wed Thu Fri Partition Account Code No Activity Arming Pre-alert Time Sat 1 2 3 4 5 6 7 8 [005][01] Def 030 [005][02] Def 030 [005][03] Def 030 [005][04] Def 030 [005][05] Def 030 [005][06] Def 030 [005][07] Def 030 [005][08] Def 030 Bell Cutoff 045 045 045 045 045 045 045 045 [005][09] Def 004 0 0 0 0 0 0 0 0 3 3 3 3 3 3 3 3 0 0 0 0 0 0 0 0 120 120 120 120 120 120 120 120 0 0 0 0 0 0 0 0 6 6 6 6 6 6 6 6 [181] [182] [183] [184] [185] [186] [187] [188] 0 0 0 0 0 0 0 0 [191] [192] [193] [194] [195] [196] [197] [198] 1 ON [351] [352] [353] [354] [355] [356] [357] [358] Alt 2nd 1st Phone Phone COM 1st 2nd Alt Phone Phone COM 1st Alt 2nd Phone Phone COM 1st Alt 2nd Phone Phone COM [375] [359] [360] [361] [362] [363] [364] [365] [366] [367] [368] [369] [370] [371] [372] [373] [374] Pulse Dialing [302] Second Telephone Number (32 Digits) [303] Third Telephone Number (32 Digits) 1st Alt 2nd Phone Phone COM [376] D [304] Call Waiting Cancel String (6 Digits) [310] System Account Code (6 Digits) Restorals Follow Zones DTMF Dialing [381] 2nd Communicator Option Codes Op Def 1 ON [382] 3rd Communicator Option Codes OFF Open After Alarm Keypad Ringback Enabled Open After Alarm Keypad Ringback Disabled Op Def 1 ON OFF Contact ID Partial Closing Identifier is “5” Contact ID Partial Closing Identifier is “4” DTMF Dial For All Attempts 2 Open After Alarm Bell Ringback Enabled Open After Alarm Bell Ringback Disabled 2 Alarm Communications Enabled During Walk Test Alarm Communications Disabled During Walk Test 5 3rd Telephone Number Enabled 3rd Telephone Number Disabled 3 SIA Sends Programmed Reporting Codes SIA Sends Automatic Reporting Codes 3 Communication Cancelled Message Enabled (ON for CP-01) Communication Cancelled Message Disabled 4 Call Waiting Cancel Enabled** Call Waiting Cancel Disabled T-Link Interface Enabled T-Link Interface Disabled 6 Alternate Dial (1st & 3rd) 7 Future Use Delinquency Follows Zone Activity (Hours) Call 1st Number, Back up to 3rd 4 5 Delinquency Follows Arming (Days) INTERNATIONAL PROGRAMMING 6 Closing Confirmation Enabled Talk/Listen on Phone Lines 1/3 No Bell Squawk On Entry Delay No Talk/Listen on Phone Lines 1/3 Talk/Listen on Phone Line 2 No Talk/Listen on Phone Line 2 6 0 0 1 2 Def 003 0 0 3 Swinger Shutdown (Tampers & Restoral) (001-014) Transmissions, 000=Disabled 3 Def 003 0 0 3 Swinger Shutdown (Maint. & Restoral) (001-014) Transmissions, 000=Disabled 4 Def 000 0 3 0 Communication Delay (001-255) Seconds 5 Def 030 0 3 0 AC Failure Communication Delay (001-255) Minutes 6 Def 010 0 1 0 TLM Trouble Delay (003-255) Number of Checks Required 7 Def 030 0 3 0 Test Transmission Cycle (Land Line) (001-255) Minutes/Days/Minutes 8 Def 030 0 3 0 Not Used Def 007 0 0 7 Zone Low Battery Transmission Delay (001-255) Days (001-255) Days/Hrs 9 Swinger Shutdown (Alarms & Restoral) 10 Def 030 0 3 0 Delinquency Transmission Delay 11 Def 000 0 0 5 Communications Cancelled Window (001-255) Minutes Contact ID Uses Programmed Reporting Codes Contact ID Uses Automatic Reporting Codes 7 Future Use 8 Local Mode Enabled Local Mode Disabled 8 Future Use AC Failure Transmission Delay is in Minutes SYSTEM OPTION CODES 1st/3rd Telephone Number Def 04 2nd Telephone Number Def 04 01 02 03 04 05 06 07 08 09 10 11 12 13 20BPS, 1400 HZ Handshake 20BPS, 2300 HZ Handshake DTMF CONTACT ID SIA FSK Pager Residential Dial 10BPS, 1400 HZ Handshake 10BPS, 2300 HZ Handshake Private Line Scantronics For Future Use Robofon CESA 200 [378] Test Transmission Time of Day 3rd Telephone Number follows format of 1st Telephone Number Def 9999 7 OFF (001-014) Transmissions AC Failure Transmission Delay is in Hours [701] 1st International Option Codes ON 5 Def 003 1 Switch to Pulse Dialing on 5th Attempt Op Def D System Test Transmission Call Directions 4 8 [350] Communicator Format Options 3rd Telephone Number follows format of 1st Telephone Number [301] First Telephone Number (32 Digits) D COMMUNICATION OPTION CODES Communications Disabled Restorals on Bell Time-out 3 System Maintenance Call Directions [377] Communication Variables OFF Communications Enabled 2 Opening/Closing Call Directions Valid entries are 001 - 255 minutes [380] 1st Communicator Option Codes Op Def [311] [312] [313] [314] [315] [316] [317] [318] Tamper/Restore Call Directions Alarm/Restore Call Directions SIA FAR (CP-01) Defaults are indicated in GREY COMMUNICATIONS [379] Periodic DLS Time of Day 3rd Telephone Number follows format of 1st Telephone Number Def 9999 ADDITIONAL REPORTING CODES (Default is FF unless indicated otherwise) 1 50 Hz AC 60 Hz AC 2 Time Base - Internal Crystal Time Base - AC Line Op Def 3 AC/DC Arming Inhibit Enabled AC/DC Arming Inhibit Disabled 1 Normally Closed Loops End-of-line Resistors 1 Test Transmission Exception Enabled Test Transmission Exception Disabled Duress Alarm Battery Trouble Restoral 4 All System Tampers Require Installer Reset All System Tampers Follow Restore 2 Double End-of-line Resistors Single End-of-line Resistors 2 Verbal Chime Enabled Verbal Chime Disabled Open After Alarm AC Failure Trouble Restoral 5 6-digit User Access Codes 4-digit User Access Codes 3 Panel shows all Troubles when armed Panel shows only Fire Troubles when armed 3 Verbal Alarm Enabled Verbal Alarm Disabled Recent Closing Bell Circuit Trouble Restoral [339] 1 [340] 17 [342] 1 [343] 17 6 Busy Tone Detection Enabled Busy Tone Detection Disabled 4 Tampers/Faults do not show as open Tampers/Faults show as open 4 Water-flow Silence Inhibit Enabled Water-flow Silence Inhibit Disabled Zone Expander Supervisory Alarm Fire Trouble Restoral 2 18 2 18 7 High Current Battery Charge Standard Current Battery Discharge 5 Auto Arm Schedule in [,][6] Auto-arm Schedule in Installer Programming Only 5 Keypad Buzzer Follows Bell Enabled Keypad Buzzer Follows Bell Disabled Zone Expander Supervisory Restore Auxiliary Power Supply Trouble Restoral 3 19 3 19 8 Standard Comms Priority UL Communications Priority (required for CP-01) 6 Audible Exit Fault Enabled Audible Exit Fault Disabled 6 Cross Zoning Enabled Cross Zoning Disabled Cross Zone Police Code Alarm TLM Trouble Restoral 4 20 4 20 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events past Shutdown 7 Exit Delay Restart Enabled (Enabled For CP-01) Exit Delay Restart Disabled Burglary NOT Verified General System Trouble Restore 5 21 5 21 8 Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal 8 AC Trouble Beeps Enabled AC Trouble Beeps Disabled Alarm Cancelled General System Supervisory Restore 6 22 6 22 7 23 7 23 8 24 8 24 9 25 9 25 [013] 1st System Option Codes [702] 2nd International Option Codes Op Def ON OFF ON Op Def ON OFF [328] MISC. Alarm Reporting Codes Pulse Dialing Make/Break Ratio is 33/67 2 Force Dialing Enabled 3 Land Line Test Transmission in Minutes Land Line Test Transmission in Days 1 Arm /Disarm Bell Squawk Enabled Arm /Disarm Bell Squawk Disabled 1 Future Use Keypad Fire Alarm Telephone Number 1 FTC Restore 4 1600 Hz Handshake Standard Handshake 2 Bell Squawk During Auto-arm No Bell Squawk During Auto-arm 2 Future Use Keypad Auxiliary Alarm Telephone Number 2 FTC Restore 5 ID Tone Enabled ID Tone Disabled 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay 3 Future Use Keypad Panic Alarm Event Buffer 75% Full Since Last Upload 6 2100 Hz ID Tone 1300 Hz ID Tone+ 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay 4 Future Use Auxiliary Input Alarm 0 7 One Time 1-Hr User Enabled DLS Window Full 6-Hr User Enabled DLS Window 5 Bell Squawk On Trouble No Bell Squawk On Trouble 5 Future Use Keypad Fire Restoral 0 8 Bell on FTC when Armed FTC Trouble only when Armed 6 Audible Exit with Urgency Silent Exit Delay 6 Future Use Keypad Auxiliary Restoral Zone Fault Alarm 7 Exit Delay Termination Enabled Exit Delay Termination Disabled 7 Future Use Keypad Panic Restoral Zone Fault Restore 8 Residential Fire Bell is Continuous Residential Fire Bell is Cut-off 8 Future Use Auxiliary Input Restoral Delinquency Code Force Dialing Disabled [700] Automatic Clock Adjust [703] Delay between Dialing Attempts 003 Valid Entries 00-99 Seconds [014] 2nd System Option Codes Op Def ON OFF Op Def ON Fire Keys Enabled [007] Master Code Def 123456 2 Panic Keys Audible (Bell / Beeps) 3 Quick Exit Enabled (Enabled For CP-01) 4 Quick Arming Enabled (No Code Required) Valid Entries 001-255 5 Code Required for Bypassing Valid Entries 001-255 Minutes 6 Master Code NOT Changeable (Enabled For CP-01) 7 TLM Enabled 8 TLM Audible (Bell) when Armed Def AAAAAA [012] Keypad Lockout Options [030] Zone Loop Response Zones (1-8) Op Def ON OFF 1 Zone 1 is Fast Loop Response Zone 1 is normal loop Response 2 Zone 2 is Fast Loop Response Zone 2 is normal loop Response 3 4 Zone 3 is Fast Loop Response Zone 4 is Fast Loop Response Zone 3 is normal loop Response Zone 4 is normal loop Response [021] 8th System Option Codes OFF 1 Lockout Duration OFF Op Def ON [347] Misc. Maintenance Reporting Codes 0 0 28 13 29 14 30 14 30 15 31 15 31 16 32 16 32 AC Trouble Displayed Valid Entries 000-005 (Enter 000 to program exact date & time) Day Def 000 Valid Entries 001-031 Days (if 000 programmed in previous section) Walk Test End Hour Def 002 Valid Entries 000-023 Hr Close by Duress Code 34 Walk Test Begin Increment Def 001 Close by Master Code 40 Periodic Test Transmission with Trouble Valid Entries 001-002 (1 or 2 Hrs forward) Close by Supervisory Code 41 Periodic Test Transmission Close by Supervisory Code 42 System Test Partial Closing Not Used 3 Future Use Keypad Lockout Quick Arming Disabled (Code Required) 4 Future Use NO Code Required for Bypassing 5 Future Use Master Code Changeable 6 Future Use Close by Duress Code 33 TLM Disabled 7 Future Use TLM Trouble Beeps when Armed 8 Future Use [341] MISC. Closing (Arming) Reporting Codes [022] 9th System Option Codes OFF Op Def ON OFF AC Trouble NOT Displayed 1 Future Use Trouble Light does NOT follow AC Status 2 Future Use 3 Blank Keypad when Not Used Keypad Always Active 3 Future Use No Code Required 4 Future Use 7 Zone 7 is Fast Loop Response Zone 7 is normal loop Response 4 Code required to remove Keypad Blanking 8 Zone 8 is Fast Loop Response Zone 8 is normal loop Response 5 Keypad Backlighting is Enabled Keypad Backlighting is Disabled 5 Future Use 6 Power Save Mode Enabled Power Save Mode Disabled 6 RF Delinquency Enabled 7 Bypass Status Displayed While Armed Bypass Status NOT Displayed While Armed 7 Future Use Keypad Tampers Disabled 8 Keypad Tampers Enabled Def 001 Quick Exit Disabled 8 Week ON 1 Valid Entries 001-012 General System Tamper Restoral . . Audible Exit Delay Stay Arming [348] Test Transmission Reporting Codes Special Closing Late to Close Exit Fault [344] MISC. Opening (Disarming) Reporting Codes RF Delinquency Disabled . [349] PC5700 Maintenance Reporting Codes Stay Arming Silent Open by Duress Code 33 PC5700 Ground Fault Trouble Open by Duress Code 34 PC5700 Ground Fault Restore Open by Master Code 40 PC5700 TLM Line 1 Trouble Open by Supervisory Code 41 PC5700 TLM Line 1 Restore Open by Supervisory Code 42 PC5700 TLM Line 2 Trouble PC5700 TLM Line 2 Restore [170] PGM Output Timer Def 005 Def 004 Op Def [172] Future Use Def 010 1 WLS Key Does NOT use Access Codes [173] Future Use Def 000 2 RF Jam Log after 5 Minutes [175] Auto-arm Postpone Timer Def 000 Valid Entries 001-255 Minutes (000 - Disable) 3 Audible RF Jam Trouble Beeps [176] Cross Zone / Police Code Timer Def 060 Valid Entries 001-255 Seconds/Minutes 4 Double Hit Enabled Double Hit Disabled 4 Test Transmission in Hours Test Transmission in Days [177] Waterflow Delay Timer Def 000 Valid Entries 001-090 Seconds 5 Late to Close Enabled Late to Close Disabled 5 Switching from AWAY to STAY disabled AWAY to STAY toggle Option Permitted Battery Trouble Alarm Auxiliary Power Supply Trouble Alarm [178] Alarm Verified for Verbal Alarm Def 015 Valid Entries 001-255 Seconds 6 Daylight Savings Time Enabled Daylight Savings Time Disabled 6 2-way Audio will NOT Disconnect for a New Event 2-way Audio Will Disconnect for a New Event AC Failure Trouble Alarm TLM Trouble Code [190] No Activity Pre-Alert Time Def 001 Valid Entries 001-255 Minutes (000-No Pre-Alert) 7 Periodic Camera Test Enabled Periodic Camera Test Disabled 7 Trouble Beeps are Silent Trouble Beeps Sound Every 10 Seconds Bell Circuit Trouble Alarm General System Trouble Valid Entries 001-255 Minutes 8 Squawk on Away Key Arming/Disarming Only Bell Squawk on all Arming / Disarming 8 Future Use Fire Trouble Alarm General System Supervisory [017] 5th System Option Codes ON [023] 10th System Option Codes OFF Op Def ON OFF WLS Key Does Uses Access Codes 1 [F] Key Beeps Only [F] Key Beeps and Sounds Bell Auto-arm Cancellation RF Jam Log after 30 Seconds 2 200 Baud Open/Close Identifier Toggle ON 200 Baud Open/Close Identifier Toggle OFF Special Opening Silent RF Jam Trouble Beeps 3 Test Transmission While Armed Only Test Transmission While Armed/Disarmed NOTE: If Week is programmed 001-005 then valid entries for Day are 000 - 006 (Sun - Sat) [169] Set Clock Back Month Def 010 Valid Entries 001-012 Week Def 005 Valid Entries 000-005 (Enter 000 to program exact date & time) Day Def 000 Valid Entries 001-031 Days (if 000 programmed in previous section) Hour Def 002 Valid Entries 000-023 Hr Decrement Def 001 Valid Entries 001-002 (1 or 2 Hrs back) . [171] Future Use Valid Entries 001-255 Seconds Daylight Savings Time Def 004 Trouble Light Flashes if AC Fails Def 004 12 29 Month Future Use 2 [199] Auto-arming Pre-alert Timer 28 13 Installer’s Lead IN 2 Zone 6 is normal loop Response Valid Entries 001-255 Seconds 12 0 Panic Keys Silent Zone 5 is normal loop Response Def 020 27 0 [167] T-Link Communications Wait For Acknowledge Delay 26 11 [168] Set Clock Forward General System Tamper Valid Entries 001-255 Seconds 10 27 Installer’s Lead OUT Zone 6 is Fast Loop Response Def 040 26 0 Future Use Zone 5 is Fast Loop Response [166] Post Dial Wait for Handshake (All Formats) DLS Lead OUT 10 11 0 1 6 Valid Entries 001-005 Attempts DLS Lead IN Opening (Disarming) General Zone Low Battery Restoral [338] MISC. Tamper Reporting Codes Fire Keys Disabled [016] 4th System Option Codes Op Def OFF 5 [165] Maximum Dialing Attempts to Each Telephone Number Def 005 [329] Priority Alarm & Restoral Closing (Arming) General Zone Low Battery Alarm Def 555555 Def 000 Def 000 ON [015] 3rd System Option Codes [006] Installer Code Number of Invalid Codes before Lockout Op Def Valid Entries 000-255 Seconds SYSTEM CODES & TIMERS [008] Maintenance Code [019] 7th System Option Codes Access Codes 1-32 Reporting Codes [346] Maintenance Restoral Reporting Codes 1 Def 60 Pulse Dialing Make/Break Ratio is 40/60 [018] 6th System Option Codes OFF NOTE: If Week is programmed 001-005 then valid entries for Day are 000 - 006 (Sun - Sat) MODULE PROGRAMMING Refer to the associated Installation Manuals for installation and programming instructions 100 95 [345] Maintenance Alarm Reporting Codes [801] [802] [803] [804] [805] [851] PC5400 Printer Module Programming PC5900 Audio Interface Alternate Communicator PC5132 Wireless Expansion PC5100 T-Link (To enable T-Link, Section [382], Option 5 must be ON 75 25 5 0 H:\PowerSeries[NEW]\PWS\29007177R001_PWS_Released.cdr Wednesday, March 08, 2006 2:02:27 PM Plate: 3 of 4