PC1616/PC1832/PC1864 v4.1 PROGRAMMING WORKSHEET

advertisement
Color profile: Generic offset separations profile
Black 133 lpi at 45 degrees
ZONE PROGRAMMING
DLS DOWNLOADING
Op Def
29007177R002
STANDARD / CP-01(SIA FAR)
Digital Security Controls
Toronto, Canada www.dsc.com
Printed in Canada
PC1616/PC1832/PC1864 v4.1
PROGRAMMING WORKSHEET
8
32 (3xPC5108)
32 (PC5132)
2
8
4
6
16 (1xPC5108)
16 (RF5108)
2
8
2
1
Answering Machine/Double Call Enabled
2 User Can Enable DLS Window
OFF
User Can NOT Enable DLS Window
PC1832 183200
Enter 6 Hexadecimal Digits
Zone Attributes
Enabled ‘S’ SIA FAR (CP-01) Only
Enter 6 Hexadecimal Digits
Enabled ‘’
Call Back Disabled
User Initiated Call Up Enabled
User Initiated Call Up Disabled
5
Auto Event Buffer Upload Enabled
Auto Event Buffer Upload Disabled
6
Future Use
8
Future Use
ZONE Definition
Panel ID Code [404]
Enter 6 Hexadecimal Digits
Call Back Enabled
Downloading
Access Code [403]
PC1616 161600
4
Future Use
Def
Answering Machine/Double Call Disabled
3
7
Panel
PC1864 186400
[405] Answering Machine Double Call Timer
Def 060
[406] Number of Rings to Answer On
1 Audible
2 Steady
3 Chime
4 Bypass
5 Force Arm
6 Swinger
7 TX Delay
8 Wireless Zn
9 Cross Zone
(001-255) Seconds
(001-255) Rings
Def 000
[499] Initiate PC-Link Downloading
Enter [499][Installer’s Code][499]
[402] DLS Downloading Telephone Number (32 Digits)
D
This Programming Worksheet provides all programming sections and default values for the
PowerSeries PC1616, PC1832 and PC1864.
This programming worksheet shall be used in conjunction with the PowerSeries PC1616, PC1832
and PC1864 Reference Manual which can be obtained from your local dealer or downloaded from
the DSC website at www.dsc.com. The Reference Manual provides a detailed description of each
programming option. Programming Options for the PC1616/PC1832/PC1864 are identical except for
the number of Zones, Partitions and On-board PGMs. Refer to the table below for available options
for each model.
PC1616
PC1832
PC1864
On-board Zones
Hardwired Zones
Wireless Zones
On-board PGMs
Keypads
Partitions
Downloading Option Codes [401]
ON
8
64 (7xPC5108)
32 (PC5132)
4
8
8
How to Program:
DSC recommends filling in the Programming Worksheet with the required programming information before
programming the system. This will reduce the time required to program and will help eliminate errors.
ZN#
SPECIAL INSTALLER FUNCTIONS
NOTE:
Programming Toggle Options:
Enter the 3-digit programming section number. The Armed light will turn OFF and the Ready light will turn ON.
The keypad will display toggle option status as indicated below:
Keypad Type
LED
Fixed-Message LCD
Programmable-Message LCD
OptionON
Zone Light ON
Indicator # ON
# Displayed
Option OFF
Zone Light OFF
Indicator # OFF
Dash [-] Displayed
To toggle an option ON or OFF, press the corresponding number on the keypad. The change will be displayed.
When all the toggle options are configured as required:
Press the [#] key to exit the programming section. The Ready light will turn OFF and the Armed light will turn ON.
NOTE: If the panel is a local system, press [#] to skip this step.
NOTE:In addition to the standard digits 0-9, HEX digits can also be programmed in the phone number if required.
HEX [A]
Not Supported
HEX [B]
Simulated [,] key
Press [,][2][,]
HEX [C]
Simulated [#] key
Press [,][3][,]
HEX [D]
Dial tone search
Press [,][4][,]
HEX [E]
Two second pause
Press [,][5][,]
Programming Decimal and Hexadecimal (HEX) Data:
Decimal:
Enter the 3-digit programming section number. The Armed light will turn OFF and The Ready light will turn ON.
Enter the data recorded in the Programming Worksheet
For sections that require multiple 2 or 3 digit numbers, the keypad will double-beep after each 2 or 3 digit entry
before moving to the next item on the list. After the last digit in the section is entered, the keypad will beep rapidly
5 times and exit the program section. The Ready light will turn OFF and the Armed light will turn ON.
For sections that do not require data for every box (such as phone numbers) press the [#] key to exit the
programming section after entering all of the required data.
The Ready light will turn OFF and the Armed light will turn ON.
Enter [#] at any time to exit a programming section and save programming changes.
Hexadecimal:
To enter a HEX digit, press the [,] key to begin HEX programming. The Ready light will FLASH.
Refer to the chart below and press the number corresponding to the HEX digit required.
The Ready light will continue to FLASH.
Press [,] again to return to normal decimal programming. The Ready light will turn ON.
HEX [A]
HEX [B]
[,] [1] [,]
[,] [2] [,]
HEX [C]
HEX [D]
[,] [3] [,]
[,] [4] [,]
HEX [E]
HEX [F]
[,] [5] [,]
[,] [6] [,]
How to Exit Installer Programming:
To exit installer programming, press the [#] key when the panel is waiting for a 3-digit section number
(the Armed light is ON).
Viewing Programming
LED and LCD5501Z Keypads
All programming sections can be viewed from an LED or LCD5501Z keypad.
When a programming section is entered, the keypad will immediately display the first digit of information
programmed in that section. The keypad displays the information using the binary format, indicated below:
See Hex data entry instructions
Value
Zone 1
Zone 2
Zone 3
Zone 4
Zone Light OFF
Zone Light ON
Use the arrow keys (< >) or press any of the Emergency keys (Fire, Auxiliary or Panic) to advance to the next digit.
When all the digits in a section have been viewed, the panel will exit the section:
the Ready light will turn OFF, and the Armed light will turn ON,
The system will wait for the next three-digit programming section number to be entered.
Press the [#] key to exit the section
LCD Keypads
When a programming section is entered, the keypad will display all the information programmed in that section.
Use the arrow keys (< >) to scroll through the data being displayed.
To exit the section, scroll past the end of the data displayed, or press the [#] key.
H:\PowerSeries[NEW]\PWS\29007177R001_PWS_Released.cdr
Wednesday, March 08, 2006 1:40:10 PM
Plate: 1 of 4
ZONE Definition
9
13
14
15
16
17
18
19
20
21
22
23
24
25
S
S
S
S
S
S
S S
S
S
S
S
S
S
PC1864/PC1832 support 32 wireless zones, PC1616 supports 16 wireless zones
RECORD ZONE LABEL HERE if APPLICABLE (Refer to Keypad Installation Manual)
ZONE TYPE
1
ZONE ATTRIBUTES
2 3 4 5 6 7
8
9
b
1
Gasb
24Hr
24Hr Heatingb
24Hr Auxiliary/Medical
24Hr Panicb
24Hr Emergencyb
24Hr Sprinklerb
24Hr Waterb
24Hr Freezeb
24Hr Latching Tamperb
Momentary Keyswitch Armb
Maintained Keyswitch Armb
Not Used
Interior Delayb
1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
ZONE Definition
9
26
29
30
31
32
33
34
35
36
37
87
88
Denotes burglary applications only
[804][01-32] SERIAL #
(Wireless)
ZONE ATTRIBUTES
2 3 4 5 6 7 8
2
f
S
1
ZONE ATTRIBUTES
2 3 4 5 6 7 8
24Hr Non-alarm
Auto Verified Fire
Fire Supervisory
Day Zoneb
Instant Stay/Away
Future Use
Future Use
24Hr Bell/Buzzer
Future Use
Night Zone
Delay 24Hr Fire (Wireless)f
Standard 24Hr Fire (Wireless)f
S
S
S
S
Denotes residential fire applications only
PARTITION ASSIGNMENT
3
4
5
6
7
8
ALARM
ZONE REPORTING CODES (Def FF)
ALARM REST
TAMPER
TAMP REST
[990] Installer Lockout Enable
Enter [990][Installer’s Code][990]
1
[001] 0 1
[101]
[202] [210]
[218]
[226]
[234]
[242]
[250]
[258]
[320]
[324]
[330]
[334]
[901] Installer Walk Test Mode Enable/Disable
Enter [,][8][Installer’s Code][901]
[991] Installer Lockout Disable
Enter [991][Installer’s Code][991]
2
[001]
0 3
[102]
[202] [210]
[218]
[226]
[234]
[242]
[250]
[258]
[320]
[324]
[330]
[334]
Enter [,][8][Installer’s Code][902]
[902] Module Supervision Reset
Enter [,][8][Installer’s Code][903]
[903] Module Supervision Field
Enter [,][8][Installer’s Code][904]
[904] Wireless Module Placement Test
[905] Future Use
Enter [,][8][Installer’s Code][906]
[906] Local Test of Downlook Remote Trigger
[992] Future Use
3
[001]
0 3
[103]
[202] [210]
[218]
[226]
[234]
[242]
[250]
[258]
[320]
[324]
[330]
[334]
[993] Restore Alternate Communicator to Default Programming
4
[001]
0 3
[104]
[202] [210]
[218]
[226]
[234]
[242]
[250]
[258]
[320]
[324]
[330]
[334]
Enter [993][Installer’s Code][993]
[994] Future Use
5
[001]
0 4
[105]
[202] [210]
[218]
[226]
[234]
[242]
[250]
[258]
[320]
[324]
[330]
[334]
[995] Restore Escort5580 to Default Programming
6
[001]
0 4
[106]
[202] [210]
[218]
[226]
[234]
[242]
[250]
[258]
[320]
[324]
[330]
[334]
Enter [995][Installer’s Code][995]
[996] Restore PC5132 to Default Programming
Enter [996][Installer’s Code][996]
7
[001]
0 4
[107]
[202] [210]
[218]
[226]
[234]
[242]
[250]
[258]
[320]
[324]
[330]
[334]
8
[001]
0 4
[108]
[202] [210]
[218]
[226]
[234]
[242]
[250]
[258]
[320]
[324]
[330]
[334]
[907] Future Use
[997] Restore PC5400 to Default Programming
Enter [997][Installer’s Code][997]
[908] Future Use
[998] Restore PC5936 to Default Programming
Enter [998][Installer’s Code][998]
9
[001]
0 0
[109]
[203]
[211]
[219]
[227]
[235]
[243]
[251]
[259]
[320]
[324]
[330]
[334]
Enter [999][Installer’s Code][999]
10
[001]
0 0
[110]
[203]
[211]
[219]
[227]
[235]
[243]
[251]
[259]
[320]
[324]
[330]
[334]
11
[001]
0 0
[111]
[203]
[211]
[219]
[227]
[235]
[243]
[251]
[259]
[320]
[324]
[330]
[334]
12
[001]
0 0
[112]
[203]
[211]
[219]
[227]
[235]
[243]
[251]
[259]
[320]
[324]
[330]
[334]
13
[001]
0 0
[113]
[203]
[211]
[219]
[227]
[235]
[243]
[251]
[259]
[320]
[324]
[330]
[334]
14
[001]
0 0
[114]
[203]
[211]
[219]
[227]
[235]
[243]
[251]
[259]
[320]
[324]
[330]
[334]
15
[001]
0 0
[115]
[203]
[211]
[219]
[227]
[235]
[243]
[251]
[259]
[320]
[324]
[330]
[334]
16
[001]
0 0
[116]
[203]
[211]
[219]
[227]
[235]
[243]
[251]
[259]
[320]
[324]
[330]
[334]
17
[002]
0 0
[117]
[204]
[212]
[220]
[228]
[236]
[244]
[252]
[260]
[321]
[325]
[331]
[335]
18
[002]
0 0
[118]
[204]
[212]
[220]
[228]
[236]
[244]
[252]
[260]
[321]
[325]
[331]
[335]
19
[002]
0 0
[119]
[204]
[212]
[220]
[228]
[236]
[244]
[252]
[260]
[321]
[325]
[331]
[335]
[909] Future Use
[999] Restore PC1616/1832/1864 to Default Programming
Wireless Placement Test Indications (Refer to PC5132 Installation Manual)
Select module/transmitter (zones 01-32). Press [#] to cancel
PLACEMENT
Good
Bad
LED KEYPAD
LED 1 ON Steady
LED 3 ON Steady
LCD KEYPAD
“GOOD”
“BAD”
Downlook Remote Trigger Test
Enter [01] to select Telephone #1 via land line
BELL/BUZZER
1 Beep / Squawk
3 Beeps / Squawks
Enter [02] to select Telephone #2 via land line
KEYPAD PROGRAMMING
NOTE: Must be performed at each KEYPAD
requiring programming
[0] Slot address (Valid Entries 0-8 for Partition, 1-8 for Slot)
[1]-[05] Function Key Assignment (Valid Entries 0-32)
LCD 5501/LED Defaults
FUNCTION KEY OPTIONS
00
01
02
03
04
05
06
07
08
09
10
Not Used
Select Partition 1
Select Partition 2
Stay Arm
Away Arm
[,][9] No-Entry Arm
[,][4] Chime ON/OFF
[,][6][----][4] System Test
[,][1] Bypass Mode
[,][2] Trouble Display
[,][3] Alarm Memory
LCD Defaults
11
12
13
14
15
16
17
18
19
20
21
[,][5] Access Code Programming
[,][6] User Functions
Command Output #1 [,][7][1]
Command Output #2 [,][7][2] Sensor Reset
General Voice Prompted Help
[,][0] Quick Exit
[,][1] Reactivate Stay/Away Zones
Identified Voice Prompted Help
Command Output #3 [,][7][3]
Future Use
Command Output #4 [,][7][4]
22
23
24
25
26
27
28
29
30
31
32
KEYPAD 1
Active Camera Monitior Selection
Bypass Recall
Recall Bypass Group
Future Use
Time of Day Programming
Select Partition 3
Select Partition 4
Select Partition 5
Select Partition 6
Select Partition 7
Select Partition 8
KEYPAD 2
KEYPAD 3
KEYPAD 4
KEYPAD 5
KEYPAD 6
KEYPAD 7
KEYPAD 8
Partition/ [020] Zone
Slot
Assigned
1 1
1 8
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
KEY 1
KEY 2
KEY 3
KEY 4
KEY 5
20
[002]
0 0
[120]
[204]
[212]
[220]
[228]
[236]
[244]
[252]
[260]
[321]
[325]
[331]
[335]
0 3
0 3
0 4
0 4
0 6
0 6
1 4
1 4
1 6
1 6
21
[002]
0 0
[121]
[204]
[212]
[220]
[228]
[236]
[244]
[252]
[260]
[321]
[325]
[331]
[335]
22
[002] 0 0
[122]
[204]
[212]
[220]
[228]
[236]
[244]
[252]
[260]
[321]
[325]
[331]
[335]
23
[002]
0 0
[123]
[204]
[212]
[220]
[228]
[236]
[244]
[252]
[260]
[321]
[325]
[331]
[335]
24
[002] 0 0
[124]
[204]
[212]
[220]
[228]
[236]
[244]
[252]
[260]
[321]
[325]
[331]
[335]
25
[002]
0 0
[125]
[205]
[213]
[221]
[229]
[237]
[245]
[253]
[261]
[321]
[325]
[331]
[335]
26
[002]
0 0
[126]
[205]
[213]
[221]
[229]
[237]
[245]
[253]
[261]
[321]
[325]
[331]
[335]
27
[002]
0 0
[127]
[205]
[213]
[221]
[229]
[237]
[245]
[253]
[261]
[321]
[325]
[331]
[335]
PGM PROGRAMMING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Residential Burglary & Fire Bell Output
Future Use
Sensor Reset [,][7][2]
2-wire Smoke Support (PGM 2 only)
System Armed Status
Ready to Arm
Keypad Buzzer Follow Mode
Courtesy Pulse
System Trouble Output (with Trouble options)
System Event Strobe (with Event options)
System Tamper (all sources: zones, keypad, modules)
TLM and Alarm
Kissoff Output
Ground Start Pulse
Remote Operation (DLS Support)
Future Use
PGM OPTIONS
[009] PGM 1
[009] PGM 2
[010] PGM 3
[010] PGM 4
[010] PGM 5
[010] PGM 6
[010] PGM 7
[010] PGM 8
[010] PGM 9
[010] PGM 10
[011] PGM 11
[011] PGM 12
[011] PGM 13
[011] PGM 14
1
Def 19
Def 10
Def 01
Def 01
Def 01
Def 01
Def 01
Def 01
Def 01
Def 01
Def 01
Def 01
Def 01
Def 01
PGM ATTRIBUTES
1 2 3 4 5 6 7 8
PGM ATTRIBUTES
1 2 3 4 5 6 7 8
PGM OUTPUT OPTIONS
Main Panel
Main Panel
Main Panel & PC5208
Main Panel & PC5208
PC5208
PC5208
PC5208
PC5208
PC5208
PC5208
PC5204
PC5204
PC5204
PC5204
[501]
[502]
[503]
[504]
[505]
[506]
[507]
[508]
[509]
[510]
[511]
[512]
[513]
[514]
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Away Armed Status
Stay Armed Status
Command Output #1 [,][7][1]
Command Output #2 [,][7][2]
Command Output #3 [,][7][3]
Command Output #4 [,][7][4]
24-Hr Silent Input
24-Hr Audible Input
Delayed Fire & Burglary Output
Future Use
Future Use
Future Use
Zone Follower
Partition Status Alarm Memory
Future Use
Future Use
PGM ATTRIBUTES
2
3
4
5
6
7
PGM ATTRIBUTES (Definitions)
1 Used only on OPT 9 (Service Req'd) and OPT 10 (Burglar Event)
2 Used only on OPT 9 (AC Fail) and OPT 10 (Fire Event)
3 True Output (enabled) Inverted Output (Off)
OPT 9 (TLM Fault) and OPT 10 (Panic Event)
4 Follows Timer (enabled) None (Disabled)
OPT 9 (FTC) and OPT 10 (Medical Event)
5 Code Req'd (enabled) No Code Req'd (disabled)
OPT 9 (Zone Fault) and OPT 10 (Supervisory Event)
6 Used only on OPT 9 (Zone Tamper) and OPT 10 (Priority Event)
7 Used only on OPT 9 (Zone Low Battery) and OPT 10 (Holdup Event)
8 Used only on OPT 9 (Loss of Clock) and OPT 10 (Follows Timer)
NOTE: If attribute 8 is ON, attributes 1-7 must also be turned ON)
PGM PARTITION ASSIGNMENT
1
2
3
4
5
6
7
8
[551]
[552]
[553]
[554]
[555]
[556]
[557]
[558]
[559]
[560]
[561]
[562]
[563]
[564]
8
NOTES
Output Types [03] and [020] can NOT
be used together on the same system
PC 1616 has 2 On-board PGMs
PC 1832 has 2 On-board PGMs
PC 1864 has 4 On-board PGMs
9
b
Enter [,][8][Installer’s Code][900]
[000] KEYPAD ENROLLMENT
You cannot enter installer programming while any aprtition is armed or in alarm.
Null Zone (Not Used)
Delay 1b
Delay 2b
Instantb
Interiorb
Interior, Stay/Awayb
Delay, Stay/Awayb
Delayed 24Hr Fire Hardwiredf
Standard 24Hr Fire Hardwired
24Hr Supervisory
24Hr Supervisory Buzzerb
24Hr Burglaryb
24Hr Holdupb
ZONE ATTRIBUTES
2 3 4 5 6 7 8
[900] Panel Version Displayed
An error tone indicates the installer code entered is incorrect,Press [#] to clear the entry then reenter the installer code.
The Armed and Ready lights indicate programming status:
Panel waiting for 3-digit section number
Panel waiting for data to be entered
Panel waiting for HEX data to be entered
Silent
Pulsed
None
None
None
None
No Delay
Hardwired
None
NOTES: Keypads are required for 24Hr buzzer zone,
To enter Installer Programming press [,][8][555555].The Program light will FLASH on LED Keypads
The display will change to ‘Enter Section’ on the LCD keypad.
Armed Light ON
Ready Light ON
Ready Light FLASHING
Disabled
00
01
02
03
04
05
06
07
08
09
10
11
12
1
28
[002]
0 0
[128]
[205]
[213]
[221]
[229]
[237]
[245]
[253]
[261]
[321]
[325]
[331]
[335]
29
[002]
0 0
[129]
[205]
[213]
[221]
[229]
[237]
[245]
[253]
[261]
[321]
[325]
[331]
[335]
30
[002]
0 0
[130]
[205]
[213]
[221]
[229]
[237]
[245]
[253]
[261]
[321]
[325]
[331]
[335]
31
[002]
0 0
[131]
[205]
[213]
[221]
[229]
[237]
[245]
[253]
[261]
[321]
[325]
[331]
[335]
32
[002]
0 0
[132]
[205]
[213]
[221]
[229]
[237]
[245]
[253]
[261]
[321]
[325]
[331]
[335]
33
[003]
0 0
[133]
[206]
[214]
[222]
[230]
[238]
[246]
[254]
[262]
[322]
[326]
[332]
[336]
34
[003]
0 0
[134]
[206]
[214]
[222]
[230]
[238]
[246]
[254]
[262]
[322]
[326]
[332]
[336]
35
[003]
0 0
[135]
[206]
[214]
[222]
[230]
[238]
[246]
[254]
[262]
[322]
[326]
[332]
[336]
36
[003]
0 0
[136]
[206]
[214]
[222]
[230]
[238]
[246]
[254]
[262]
[322]
[326]
[332]
[336]
37
[003]
0 0
[137]
[206]
[214]
[222]
[230]
[238]
[246]
[254]
[262]
[322]
[326]
[332]
[336]
38
[003]
0 0
[138]
[206]
[214]
[222]
[230]
[238]
[246]
[254]
[262]
[322]
[326]
[332]
[336]
39
[003]
0 0
[139]
[206]
[214]
[222]
[230]
[238]
[246]
[254]
[262]
[322]
[326]
[332]
[336]
40
[003]
0 0
[140]
[206]
[214]
[222]
[230]
[238]
[246]
[254]
[262]
[322]
[326]
[332]
[336]
41
[003]
0 0
[141]
[207]
[215]
[223]
[231]
[239]
[247]
[255]
[263]
[322]
[326]
[332]
[336]
42
[003]
0 0
[142]
[207]
[215]
[223]
[231]
[239]
[247]
[255]
[263]
[322]
[326]
[332]
[336]
43
[003]
0 0
[143]
[207]
[215]
[223]
[231]
[239]
[247]
[255]
[263]
[322]
[326]
[332]
[336]
44
[003]
0 0
[144]
[207]
[215]
[223]
[231]
[239]
[247]
[255]
[263]
[322]
[326]
[332]
[336]
45
[003]
0 0
[145]
[207]
[215]
[223]
[231]
[239]
[247]
[255]
[263]
[322]
[326]
[332]
[336]
46
[003]
0 0
[146]
[207]
[215]
[223]
[231]
[239]
[247]
[255]
[263]
[322]
[326]
[332]
[336]
47
[003]
0 0
[147]
[207]
[215]
[223]
[231]
[239]
[247]
[255]
[263]
[322]
[326]
[332]
[336]
48
[003]
0 0
[148]
[207]
[215]
[223]
[231]
[239]
[247]
[255]
[263]
[322]
[326]
[332]
[336]
49
[004] 0 0
[149]
[208]
[216]
[224]
[232]
[240]
[248]
[256]
[264]
[323]
[327]
[333]
[337]
50
[004]
0 0
[150]
[208]
[216]
[224]
[232]
[240]
[248]
[256]
[264]
[323]
[327]
[333]
[337]
51
[004] 0 0
[151]
[208]
[216]
[224]
[232]
[240]
[248]
[256]
[264]
[323]
[327]
[333]
[337]
52
[004]
0 0
[152]
[208]
[216]
[224]
[232]
[240]
[248]
[256]
[264]
[323]
[327]
[333]
[337]
53
[004]
0 0
[153]
[208]
[216]
[224]
[232]
[240]
[248]
[256]
[264]
[323]
[327]
[333]
[337]
54
[004]
0 0
[154]
[208]
[216]
[224]
[232]
[240]
[248]
[256]
[264]
[323]
[327]
[333]
[337]
55
[004]
0 0
[155]
[208]
[216]
[224]
[232]
[240]
[248]
[256]
[264]
[323]
[327]
[333]
[337]
56
[004]
0 0
[156]
[208]
[216]
[224]
[232]
[240]
[248]
[256]
[264]
[323]
[327]
[333]
[337]
57
[004]
0 0
[157]
[209]
[217]
[225]
[233]
[241]
[249]
[257]
[265]
[323]
[327]
[333]
[337]
58
[004]
0 0
[158]
[209]
[217]
[225]
[233]
[241]
[249]
[257]
[265]
[323]
[327]
[333]
[337]
59
[004]
0 0
[159]
[209]
[217]
[225]
[233]
[241]
[249]
[257]
[265]
[323]
[327]
[333]
[337]
60
[004]
0 0
[160]
[209]
[217]
[225]
[233]
[241]
[249]
[257]
[265]
[323]
[327]
[333]
[337]
61
[004]
0 0
[161]
[209]
[217]
[225]
[233]
[241]
[249]
[257]
[265]
[323]
[327]
[333]
[337]
62
[004]
0 0
[162]
[209]
[217]
[225]
[233]
[241]
[249]
[257]
[265]
[323]
[327]
[333]
[337]
63
[004]
0 0
[163]
[209]
[217]
[225]
[233]
[241]
[249]
[257]
[265]
[323]
[327]
[333]
[337]
64
[004]
0 0
[164]
[209]
[217]
[225]
[233]
[241]
[249]
[257]
[265]
[323]
[327]
[333]
[337]
100
95
75
25
5
0
Color profile: Generic offset separations profile
Black 133 lpi at 45 degrees
COMMUNICATOR CALL DIRECTIONS
PARTITION PROGRAMMING
[201] Partition
Select Mask
Entry Delay 1 Entry Delay 2
AUTO-ARM TIMES
Exit Delay
Sun
Mon
Tue
Wed
Thu
Fri
Partition Account
Code
No Activity Arming
Pre-alert Time
Sat
1
2
3
4
5
6
7
8
[005][01] Def 030
[005][02] Def 030
[005][03] Def 030
[005][04] Def 030
[005][05] Def 030
[005][06] Def 030
[005][07] Def 030
[005][08] Def 030
Bell Cutoff
045
045
045
045
045
045
045
045
[005][09] Def 004
0
0
0
0
0
0
0
0
3
3
3
3
3
3
3
3
0
0
0
0
0
0
0
0
120
120
120
120
120
120
120
120
0
0
0
0
0
0
0
0
6
6
6
6
6
6
6
6
[181]
[182]
[183]
[184]
[185]
[186]
[187]
[188]
0
0
0
0
0
0
0
0
[191]
[192]
[193]
[194]
[195]
[196]
[197]
[198]
1 ON
[351]
[352]
[353]
[354]
[355]
[356]
[357]
[358]
Alt
2nd
1st
Phone Phone COM
1st
2nd
Alt
Phone Phone COM
1st
Alt
2nd
Phone Phone COM
1st
Alt
2nd
Phone Phone COM
[375] [359]
[360]
[361]
[362]
[363]
[364]
[365]
[366]
[367]
[368]
[369]
[370]
[371]
[372]
[373]
[374]
Pulse Dialing
[302] Second Telephone Number (32 Digits)
[303] Third Telephone Number (32 Digits)
1st
Alt
2nd
Phone Phone COM
[376] D
[304] Call Waiting Cancel String (6 Digits)
[310] System Account Code (6 Digits)
Restorals Follow Zones
DTMF Dialing
[381] 2nd Communicator Option Codes
Op Def
1
ON
[382] 3rd Communicator Option Codes
OFF
Open After Alarm Keypad Ringback Enabled
Open After Alarm Keypad Ringback Disabled
Op Def
1
ON
OFF
Contact ID Partial Closing Identifier is “5”
Contact ID Partial Closing Identifier is “4”
DTMF Dial For All Attempts
2
Open After Alarm Bell Ringback Enabled
Open After Alarm Bell Ringback Disabled
2
Alarm Communications Enabled During Walk Test
Alarm Communications Disabled During Walk Test
5
3rd Telephone Number Enabled
3rd Telephone Number Disabled
3
SIA Sends Programmed Reporting Codes
SIA Sends Automatic Reporting Codes
3 Communication Cancelled Message Enabled (ON for CP-01)
Communication Cancelled Message Disabled
4
Call Waiting Cancel Enabled**
Call Waiting Cancel Disabled
T-Link Interface Enabled
T-Link Interface Disabled
6
Alternate Dial (1st & 3rd)
7
Future Use
Delinquency Follows Zone Activity (Hours)
Call 1st Number, Back up to 3rd
4
5 Delinquency Follows Arming (Days)
INTERNATIONAL PROGRAMMING
6 Closing Confirmation Enabled
Talk/Listen on Phone Lines 1/3
No Bell Squawk On Entry Delay
No Talk/Listen on Phone Lines 1/3
Talk/Listen on Phone Line 2
No Talk/Listen on Phone Line 2
6
0
0
1
2
Def 003
0
0
3
Swinger Shutdown (Tampers & Restoral) (001-014) Transmissions, 000=Disabled
3
Def 003
0
0
3
Swinger Shutdown (Maint. & Restoral)
(001-014) Transmissions, 000=Disabled
4
Def 000
0
3
0
Communication Delay
(001-255) Seconds
5
Def 030
0
3
0
AC Failure Communication Delay
(001-255) Minutes
6
Def 010
0
1
0
TLM Trouble Delay
(003-255) Number of Checks Required
7
Def 030
0
3
0
Test Transmission Cycle (Land Line)
(001-255) Minutes/Days/Minutes
8
Def 030
0
3
0
Not Used
Def 007
0
0
7
Zone Low Battery Transmission Delay
(001-255) Days
(001-255) Days/Hrs
9
Swinger Shutdown (Alarms & Restoral)
10 Def 030
0
3
0
Delinquency Transmission Delay
11 Def 000
0
0
5
Communications Cancelled Window (001-255) Minutes
Contact ID Uses Programmed Reporting Codes
Contact ID Uses Automatic Reporting Codes
7
Future Use
8
Local Mode Enabled
Local Mode Disabled
8
Future Use
AC Failure Transmission Delay is in Minutes
SYSTEM OPTION CODES
1st/3rd Telephone Number
Def 04
2nd Telephone Number
Def 04
01
02
03
04
05
06
07
08
09
10
11
12
13
20BPS, 1400 HZ Handshake
20BPS, 2300 HZ Handshake
DTMF CONTACT ID
SIA FSK
Pager
Residential Dial
10BPS, 1400 HZ Handshake
10BPS, 2300 HZ Handshake
Private Line
Scantronics
For Future Use
Robofon
CESA 200
[378] Test Transmission Time of Day
3rd Telephone Number follows format of 1st Telephone Number
Def 9999
7
OFF
(001-014) Transmissions
AC Failure Transmission Delay is in Hours
[701] 1st International Option Codes
ON
5
Def 003
1
Switch to Pulse Dialing on 5th Attempt
Op Def
D
System Test Transmission
Call Directions
4
8
[350] Communicator Format Options
3rd Telephone Number follows format of 1st Telephone Number
[301] First Telephone Number (32 Digits)
D
COMMUNICATION OPTION CODES
Communications Disabled
Restorals on Bell Time-out
3
System Maintenance
Call Directions
[377] Communication Variables
OFF
Communications Enabled
2
Opening/Closing
Call Directions
Valid entries are 001 - 255 minutes
[380] 1st Communicator Option Codes
Op Def
[311]
[312]
[313]
[314]
[315]
[316]
[317]
[318]
Tamper/Restore
Call Directions
Alarm/Restore
Call Directions
SIA FAR (CP-01) Defaults are indicated in GREY
COMMUNICATIONS
[379] Periodic DLS Time of Day
3rd Telephone Number follows format of 1st Telephone Number
Def 9999
ADDITIONAL REPORTING CODES (Default is FF unless indicated otherwise)
1
50 Hz AC
60 Hz AC
2
Time Base - Internal Crystal
Time Base - AC Line
Op Def
3
AC/DC Arming Inhibit Enabled
AC/DC Arming Inhibit Disabled
1
Normally Closed Loops
End-of-line Resistors
1
Test Transmission Exception Enabled
Test Transmission Exception Disabled
Duress Alarm
Battery Trouble Restoral
4
All System Tampers Require Installer Reset
All System Tampers Follow Restore
2
Double End-of-line Resistors
Single End-of-line Resistors
2
Verbal Chime Enabled
Verbal Chime Disabled
Open After Alarm
AC Failure Trouble Restoral
5
6-digit User Access Codes
4-digit User Access Codes
3 Panel shows all Troubles when armed
Panel shows only Fire Troubles when armed
3
Verbal Alarm Enabled
Verbal Alarm Disabled
Recent Closing
Bell Circuit Trouble Restoral
[339] 1
[340] 17
[342] 1
[343] 17
6
Busy Tone Detection Enabled
Busy Tone Detection Disabled
4
Tampers/Faults do not show as open
Tampers/Faults show as open
4
Water-flow Silence Inhibit Enabled
Water-flow Silence Inhibit Disabled
Zone Expander Supervisory Alarm
Fire Trouble Restoral
2
18
2
18
7
High Current Battery Charge
Standard Current Battery Discharge
5 Auto Arm Schedule in [,][6]
Auto-arm Schedule in Installer Programming Only
5
Keypad Buzzer Follows Bell Enabled
Keypad Buzzer Follows Bell Disabled
Zone Expander Supervisory Restore
Auxiliary Power Supply Trouble Restoral
3
19
3
19
8 Standard Comms Priority
UL Communications Priority (required for CP-01)
6 Audible Exit Fault Enabled
Audible Exit Fault Disabled
6
Cross Zoning Enabled
Cross Zoning Disabled
Cross Zone Police Code Alarm
TLM Trouble Restoral
4
20
4
20
7 Event Buffer Follows Swinger Shutdown
Event Buffer Logs Events past Shutdown
7
Exit Delay Restart Enabled (Enabled For CP-01)
Exit Delay Restart Disabled
Burglary NOT Verified
General System Trouble Restore
5
21
5
21
8
Temporal Three Fire Signal Enabled
Standard Pulsed Fire Signal
8
AC Trouble Beeps Enabled
AC Trouble Beeps Disabled
Alarm Cancelled
General System Supervisory Restore
6
22
6
22
7
23
7
23
8
24
8
24
9
25
9
25
[013] 1st System Option Codes
[702] 2nd International Option Codes
Op Def
ON
OFF
ON
Op Def
ON
OFF
[328] MISC. Alarm Reporting Codes
Pulse Dialing Make/Break Ratio is 33/67
2 Force Dialing Enabled
3
Land Line Test Transmission in Minutes
Land Line Test Transmission in Days
1
Arm /Disarm Bell Squawk Enabled
Arm /Disarm Bell Squawk Disabled
1
Future Use
Keypad Fire Alarm
Telephone Number 1 FTC Restore
4
1600 Hz Handshake
Standard Handshake
2
Bell Squawk During Auto-arm
No Bell Squawk During Auto-arm
2
Future Use
Keypad Auxiliary Alarm
Telephone Number 2 FTC Restore
5
ID Tone Enabled
ID Tone Disabled
3
Bell Squawk On Exit Delay
No Bell Squawk On Exit Delay
3
Future Use
Keypad Panic Alarm
Event Buffer 75% Full Since Last Upload
6
2100 Hz ID Tone
1300 Hz ID Tone+
4
Bell Squawk On Entry Delay
No Bell Squawk On Entry Delay
4
Future Use
Auxiliary Input Alarm
0
7
One Time 1-Hr User Enabled DLS Window
Full 6-Hr User Enabled DLS Window
5
Bell Squawk On Trouble
No Bell Squawk On Trouble
5
Future Use
Keypad Fire Restoral
0
8
Bell on FTC when Armed
FTC Trouble only when Armed
6 Audible Exit with Urgency
Silent Exit Delay
6
Future Use
Keypad Auxiliary Restoral
Zone Fault Alarm
7
Exit Delay Termination Enabled
Exit Delay Termination Disabled
7
Future Use
Keypad Panic Restoral
Zone Fault Restore
8
Residential Fire Bell is Continuous
Residential Fire Bell is Cut-off
8
Future Use
Auxiliary Input Restoral
Delinquency Code
Force Dialing Disabled
[700] Automatic Clock Adjust
[703] Delay between Dialing Attempts
003
Valid Entries 00-99 Seconds
[014] 2nd System Option Codes
Op Def
ON
OFF
Op Def
ON
Fire Keys Enabled
[007] Master Code
Def 123456
2
Panic Keys Audible (Bell / Beeps)
3 Quick Exit Enabled (Enabled For CP-01)
4 Quick Arming Enabled (No Code Required)
Valid Entries 001-255
5
Code Required for Bypassing
Valid Entries 001-255 Minutes
6 Master Code NOT Changeable (Enabled For CP-01)
7 TLM Enabled
8
TLM Audible (Bell) when Armed
Def AAAAAA
[012] Keypad Lockout Options
[030] Zone Loop Response Zones (1-8)
Op Def
ON
OFF
1
Zone 1 is Fast Loop Response
Zone 1 is normal loop Response
2
Zone 2 is Fast Loop Response
Zone 2 is normal loop Response
3
4
Zone 3 is Fast Loop Response
Zone 4 is Fast Loop Response
Zone 3 is normal loop Response
Zone 4 is normal loop Response
[021] 8th System Option Codes
OFF
1 Lockout Duration
OFF
Op Def
ON
[347] Misc. Maintenance Reporting Codes
0
0
28
13
29
14
30
14
30
15
31
15
31
16
32
16
32
AC Trouble Displayed
Valid Entries 000-005
(Enter 000 to program exact date & time)
Day
Def 000
Valid Entries 001-031 Days
(if 000 programmed in previous section)
Walk Test End
Hour
Def 002
Valid Entries 000-023 Hr
Close by Duress Code 34
Walk Test Begin
Increment
Def 001
Close by Master Code 40
Periodic Test Transmission with Trouble
Valid Entries 001-002
(1 or 2 Hrs forward)
Close by Supervisory Code 41
Periodic Test Transmission
Close by Supervisory Code 42
System Test
Partial Closing
Not Used
3
Future Use
Keypad Lockout
Quick Arming Disabled (Code Required)
4
Future Use
NO Code Required for Bypassing
5
Future Use
Master Code Changeable
6
Future Use
Close by Duress Code 33
TLM Disabled
7
Future Use
TLM Trouble Beeps when Armed
8
Future Use
[341] MISC. Closing (Arming) Reporting Codes
[022] 9th System Option Codes
OFF
Op Def
ON
OFF
AC Trouble NOT Displayed
1
Future Use
Trouble Light does NOT follow AC Status
2
Future Use
3
Blank Keypad when Not Used
Keypad Always Active
3
Future Use
No Code Required
4
Future Use
7
Zone 7 is Fast Loop Response
Zone 7 is normal loop Response
4
Code required to remove Keypad Blanking
8
Zone 8 is Fast Loop Response
Zone 8 is normal loop Response
5 Keypad Backlighting is Enabled
Keypad Backlighting is Disabled
5
Future Use
6
Power Save Mode Enabled
Power Save Mode Disabled
6
RF Delinquency Enabled
7
Bypass Status Displayed While Armed
Bypass Status NOT Displayed While Armed
7
Future Use
Keypad Tampers Disabled
8
Keypad Tampers Enabled
Def 001
Quick Exit Disabled
8
Week
ON
1 Valid Entries 001-012
General System Tamper Restoral
.
.
Audible Exit Delay Stay Arming
[348] Test Transmission Reporting Codes
Special Closing
Late to Close
Exit Fault
[344] MISC. Opening (Disarming) Reporting Codes
RF Delinquency Disabled
.
[349] PC5700 Maintenance Reporting Codes
Stay Arming Silent
Open by Duress Code 33
PC5700 Ground Fault Trouble
Open by Duress Code 34
PC5700 Ground Fault Restore
Open by Master Code 40
PC5700 TLM Line 1 Trouble
Open by Supervisory Code 41
PC5700 TLM Line 1 Restore
Open by Supervisory Code 42
PC5700 TLM Line 2 Trouble
PC5700 TLM Line 2 Restore
[170] PGM Output Timer
Def 005
Def 004
Op Def
[172] Future Use
Def 010
1 WLS Key Does NOT use Access Codes
[173] Future Use
Def 000
2
RF Jam Log after 5 Minutes
[175] Auto-arm Postpone Timer
Def 000
Valid Entries 001-255 Minutes (000 - Disable)
3
Audible RF Jam Trouble Beeps
[176] Cross Zone / Police Code Timer
Def 060
Valid Entries 001-255 Seconds/Minutes
4
Double Hit Enabled
Double Hit Disabled
4
Test Transmission in Hours
Test Transmission in Days
[177] Waterflow Delay Timer
Def 000
Valid Entries 001-090 Seconds
5
Late to Close Enabled
Late to Close Disabled
5
Switching from AWAY to STAY disabled
AWAY to STAY toggle Option Permitted
Battery Trouble Alarm
Auxiliary Power Supply Trouble Alarm
[178] Alarm Verified for Verbal Alarm
Def 015
Valid Entries 001-255 Seconds
6
Daylight Savings Time Enabled
Daylight Savings Time Disabled
6
2-way Audio will NOT Disconnect for a New Event
2-way Audio Will Disconnect for a New Event
AC Failure Trouble Alarm
TLM Trouble Code
[190] No Activity Pre-Alert Time
Def 001
Valid Entries 001-255 Minutes (000-No Pre-Alert)
7 Periodic Camera Test Enabled
Periodic Camera Test Disabled
7
Trouble Beeps are Silent
Trouble Beeps Sound Every 10 Seconds
Bell Circuit Trouble Alarm
General System Trouble
Valid Entries 001-255 Minutes
8
Squawk on Away Key Arming/Disarming Only
Bell Squawk on all Arming / Disarming
8
Future Use
Fire Trouble Alarm
General System Supervisory
[017] 5th System Option Codes
ON
[023] 10th System Option Codes
OFF
Op Def
ON
OFF
WLS Key Does Uses Access Codes
1
[F] Key Beeps Only
[F] Key Beeps and Sounds Bell
Auto-arm Cancellation
RF Jam Log after 30 Seconds
2
200 Baud Open/Close Identifier Toggle ON
200 Baud Open/Close Identifier Toggle OFF
Special Opening
Silent RF Jam Trouble Beeps
3
Test Transmission While Armed Only
Test Transmission While Armed/Disarmed
NOTE: If Week is programmed 001-005 then valid entries for Day are 000 - 006 (Sun - Sat)
[169] Set Clock Back
Month
Def 010
Valid Entries 001-012
Week
Def 005
Valid Entries 000-005
(Enter 000 to program exact date & time)
Day
Def 000
Valid Entries 001-031 Days
(if 000 programmed in previous section)
Hour
Def 002
Valid Entries 000-023 Hr
Decrement
Def 001
Valid Entries 001-002
(1 or 2 Hrs back)
.
[171] Future Use
Valid Entries 001-255 Seconds
Daylight Savings Time
Def 004
Trouble Light Flashes if AC Fails
Def 004
12
29
Month
Future Use
2
[199] Auto-arming Pre-alert Timer
28
13
Installer’s Lead IN
2
Zone 6 is normal loop Response
Valid Entries 001-255 Seconds
12
0
Panic Keys Silent
Zone 5 is normal loop Response
Def 020
27
0
[167] T-Link Communications Wait For Acknowledge Delay
26
11
[168] Set Clock Forward
General System Tamper
Valid Entries 001-255 Seconds
10
27
Installer’s Lead OUT
Zone 6 is Fast Loop Response
Def 040
26
0
Future Use
Zone 5 is Fast Loop Response
[166] Post Dial Wait for Handshake (All Formats)
DLS Lead OUT
10
11
0
1
6
Valid Entries 001-005 Attempts
DLS Lead IN
Opening (Disarming)
General Zone Low Battery Restoral
[338] MISC. Tamper Reporting Codes
Fire Keys Disabled
[016] 4th System Option Codes
Op Def
OFF
5
[165] Maximum Dialing Attempts to Each Telephone Number Def 005
[329] Priority Alarm & Restoral
Closing (Arming)
General Zone Low Battery Alarm
Def 555555
Def 000
Def 000
ON
[015] 3rd System Option Codes
[006] Installer Code
Number of Invalid Codes before Lockout
Op Def
Valid Entries 000-255 Seconds
SYSTEM CODES & TIMERS
[008] Maintenance Code
[019] 7th System Option Codes
Access Codes 1-32
Reporting Codes
[346] Maintenance Restoral Reporting Codes
1
Def 60
Pulse Dialing Make/Break Ratio is 40/60
[018] 6th System Option Codes
OFF
NOTE: If Week is programmed 001-005 then valid entries for Day are 000 - 006 (Sun - Sat)
MODULE PROGRAMMING
Refer to the associated Installation Manuals
for installation and programming instructions
100
95
[345] Maintenance Alarm Reporting Codes
[801]
[802]
[803]
[804]
[805]
[851]
PC5400 Printer Module Programming
PC5900 Audio Interface
Alternate Communicator
PC5132 Wireless Expansion
PC5100
T-Link (To enable T-Link, Section [382], Option 5
must be ON
75
25
5
0
H:\PowerSeries[NEW]\PWS\29007177R001_PWS_Released.cdr
Wednesday, March 08, 2006 2:02:27 PM
Plate: 3 of 4
Download