Construction ID – EPS-20G Engineered wooden floor (floating) Direct installation System IDEAL EPS 240 kPa 1,5 kN/m² 1 T&G engineered timber ≤20mm 2 UFH compatible underlay 3mm 3 JUPITER IDEAL EPS 30mm 4 Perimeter support batten 5 Perimeter insulation 1 2 5 3 4 6 Intermediate supporting ply 7 Primary insulation i.e. Kingspan 6 7 98-148 mm + Technical Data Construction suitable for floors with significant heat loss below Construction height** mm 98-148 Height without floor finish Weight** kg/m² 15-17 Weight without floor finish Thermal resistance R* m²K/W 3,379 Heat exchange coefficient W/m²K 0,17-0,21 Uniform Distributed Load (UDL) kN/m² 1,5 Point load (≥ 20cm²) kN 1,0 Impact sound reduction dB - Area of application * Based on 50-100mm Kingspan Kooltherm K3 ** Based on Kingspan Kooltherm K3 and the additional properties of the JUPITER IDEAL 30mm element. The resistance does not include for thermal resistance offered by the ground conditions. Ground floors or floors located above unheated rooms such as garages, basements etc. 20°C t: 0044 (0) 1276 859066 Construction height 18mm Installation information Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per DIN 18202 table 3, group 4. Construction tested with Kingspan Kooltherm K3 ≤ 100mm Working in conjunction with © jupiterunderfloorheating.com For upper floor installation see construction EPS-50U.