Design Stage Uncertainty Problem
An ADC is to be used to measure the output from a thermocouple. The nominal
temperature expected will be about 20 °C. Estimate the design-stage uncertainty in
this combination. The following information is available:
ADC
Gain:
Range:
Resolution:
Accuracy:
Thermocouple
Sensitivity:
Linearity:
Repeatability:
Resolution:
1
±1 volt
10 bits
within 0.001% of reading
10-4 V/°C
within 1 mVolt/°C over range
within 2 mV/°C over range
negligible
1) The voltage measurement design stage uncertainty of the ADC is
( )
= ± ( ( ) ) + ( 2 ×10 )
1
a) u0 = ± 2
b) ( ud ) E
c)
2
210
1
2
( ud )E = ± 12
2
210
2
−8
E
( ) (
2
210
2
E
+ 2 ×10−8
)
2
E
2
E
d) None of the above
2) The design stage uncertainty of the thermocouple can be assumed to be
2
D
D
D
D
a) ± ⎡⎣(1 mV/ C) × 20 C ⎤⎦ + ⎡⎣ 2 mV/ C × 20 C ⎤⎦
b) ±
2
2
2
1
⎡⎣(1 mV/ D C) × 20 D C ⎤⎦ + ⎡⎣ 2 mV/ DC × 20 DC ⎤⎦
2
c) ± [1 mV ] + [ 2 mV ]
d) None of the above
2
2
3) A linear potentiometer as used in the fourth lab in combination with the ADC used
to acquire the output voltage has a position measurement zero order uncertainty of
__________ where K is the static sensitivity of the position vs. voltage calibration
and Q is the resolution of the ADC.
a) ± ½ (K Q)
b) ± (K Q)
c) ± ½ Q
d) ± Q
e) None of the above
+∞
4) The delta function integral
a) 1
b) ½
c) 0
d) -1
e) None of the above
∫ δ (t )dt
−∞
is defined to be equal to: