ROUND TAPERED STEEL POLE (E-PSR SERIES) - E

advertisement
ROUND TAPERED STEEL POLE
(E-PSR SERIES)
Applications: Parking lots, roadways and general area lighting.
2" Pipe
2" PE
PI
(2.375"
(2.37
5"O.D.)
D.)
O.
4"
•
•
•
•
•
•
•
•
•
•
•
•
Catalog #
Length
Base O.D. x Top O.D.
x Wall Thickness
Bolt Circle Range
Anchor Bolt Size
Structural
Weight of Pole
E-PSRE25CTDB
25'
7.0" x 3.5" RND x 0.120"
10.0/9.5 - 10.5"
1" - 8 x 36" + 4"
200
E-PSRE30CTDB
30'
8.0" x 3.8" RND x 0.120"
11.0/10.5 - 11.5"
1" - 8 x 36" + 4"
265
E-PSRE35CTDB
35'
8.5" x 3.6" RND x 0.120"
11.5/11 - 12"
1" - 8 x 36" + 4"
315
E-PSRE39CTDB
39'
9.0" x 3.6" RND x 0.120"
12.5/12 - 13"
1" - 8 x 36" + 4"
355
E-PSRE45CTDB
45'
10.0" x 3.7" RND x 0.120"
13.5/13 - 14"
1" - 8 x 36" + 4"
450
E-PSRE50CTDB
50'
10.0" x 3.0" RND x 0.120"
13.5/13 - 14"
1" - 8 x 36" + 4"
475
Construction & Materials
Mechanically cleaned and coated with an electrostatically applied,baked-on powder top coat
Painted in dark bronze to match fixtures
Partially galvanized anchor bolts and hardware included
Anchor bolts are made from carbon steel bar conforming to AASHTO
and ASTM Grade-55 requirements
Base is supplied with slotted anchor bolt openings for range of boltcircles to be utilized
Base plate telescopes the pole shaft and is circumferentially welded top and bottom
Full base cover is included with each pole and made from ABS plastic;
secured together with two plastic, hand push rivets
Rectangular shaped handhole is furnished and includes a steel cover,
attachment bar with machine screw
Handhole is located 18-inches above the pole base
Ground lug is provided near the handhole and includes a hex-head bolt and nut
Removable pole cap is included with each pole configured for fixture side mounting or no drill
Poles with tenon top configuration do not include a pole cap
Performance
• 1-year limited warranty
Electrical
Regulatory
Due to continuous product improvement, information in this document is subject to change. All published photometric testing performed to IESNA LM-79-08
standards by a NVLAP certified laboratory. Fixture photometry was completed on a single representative fixture. Actual production units may vary up to
±10% of initial delivered lumens. Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ fixture testing.
1501 96th Street, Sturtevant, WI 53177 | Phone (888)243-9445 | Fax (262)504-5409 | www.e–conolight.com
ROUND TAPERED STEEL POLE
(E-PSR SERIES)
EPA Information
80 MPH
90 MPH
100 MPH
Pole Shaft
Bolt Circle
Range
Anchor
Bolt Size
Max EPA
Max
Fixture
Weight
Max EPA
Max
Fixture
Weight
Max EPA
Max
Fixture
Weight
7.0" x 3.5" RND x 25'
9.5-10.5"
1"
20.3
507
16.2
405
13.1
327
8.0" x 3.8" RND x 30'
10.5-11.5"
1"
18.9
473
14.9
373
12.0
300
8.5" x 3.6" RND x 35'
11-12"
1"
18.9
472
15.1
377
12.2
305
9.0" x 3.6" RND x 39'
12-13"
1"
17.2
430
13.5
338
10.8
270
10.0" x 3.7" RND x 45'
13-14"
1"
17.4
435
13.5
338
10.6
265
10.0" x 3.0" RND x 50'
13-14"
1"
13.2
330
10.6
265
8.3
208
For mounting other manufacturers' fixtures, please reference EPA and maximum fixture weight information above.
The maximum wind zone chart is included only for reference. Soil conditions can vary substantially within an area.
Installers are advised to work with an engineering firm to determine suitable poles and EPA loadings for every installation.
Seattle
Spokane
Havre
Great Falls
Portland
International
Falls
Williston
Missoula
Bismarck
Pendleton
90 (40)
Tonopah
Milford
Grand
Junction
Denver
Burlington
Lake
Huron
Buffalo
Lansing
La
Kansas
City
Dodge City
Springfield Indianapolis
Columbus
Albuquerque
San Diego
Philadelphia
Washington
Richmond
130 (58)
140 (63)
Norfolk
Cape Hatteras
Raleigh
Amarillo
Nashville
Knoxville
Memphis
Atlanta
Oklahoma City
Little Rock
Phoenix
Wilmington
Columbia
140 (63)
Birmingham
Abilene
Fort Worth
Shreveport
El Paso
130 (58)
New York
Pittsburgh
Harrisburg
Las Vegas
Los Angeles
90 (40)
100 (45)
110 (49)
120 (54)
Hartford
E
ke
Charleston
Lexington
St. Louis
Boston
Albany
rie
Detroit
Portland
Concord
Lake
Ontario
Chicago
Lincoln Des Moines
North
Platte
Lake Mich
igan
Racine
Dubuque
Cheyenne
Salt Lake City
Fresno
Green Bay
Lander
Winnemucca
Reno
San Francisco
Minneapolis
Huron
Rapid City
Pocatello
Sacramento
Sault Ste. Marie
Duluth
Boise
90 (40)
Eureka
Fargo
Billings
Burns
Roseburg
Caribou
Lake
Superior
Charleston
Jackson
Jacksonville
Del Rio
San Antonio
New Orleans
140 (63)
Legend
Special Wind Region
Population Center
Houston
Brownsville
Pensacola
140 (63)
Tampa
150 (67)
150 (67)
Miami
140 (63)
130 (58)
90 (40)
100 (45) 120 (54)
110 (49)
150 (67)
Due to continuous product improvement, information in this document is subject to change. All published photometric testing performed to IESNA LM-79-08
standards by a NVLAP certified laboratory. Fixture photometry was completed on a single representative fixture. Actual production units may vary up to
±10% of initial delivered lumens. Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ fixture testing.
1501 96th Street, Sturtevant, WI 53177 | Phone (888)243-9445 | Fax (262)504-5409 | www.e–conolight.com
Download