Contamination Test Unit - CTU 1000

advertisement
ContaminationTest Unit
CTU 1000 Series
The Hydac ContaminationTest Unit
CTU 1000 series is used to determine
the surface cleanliness of lightly
contaminated components.
The reason behind this are the ever
increasing demands on life
expectancy of individual components
and assemblies which has meant
growing demands for technical
cleanliness of components and
systems. Starting with production,
assembly and storage, this extends
right through to operation of the
complete system.
By analyzing the type, size and
quantity of the contamination, quality
standards can be verified and
documented, and the required
measures for improvement can be
implemented.
Applications
zzAutomotive and supplier industry
zzTransmission and engine builders
zzMobile hydraulics
zzManufacturers of hydraulic and
lubrication systems and
components
Advantages
zzReduction in costs as a result of
fewer production failures
zzIdentification and elimination of
weak processes
zzReduction in start-up breakdowns
zzOptimization of both internal and
external handling processes
zzCustomized documentation of the
technical cleanliness of components
Technical Details
Dimensions, overall
(Height x Width x Depth)
Weight:
Version
Power consumption
Ambient temperature
Analysis cabinet (clean box)
Material of Clean Box
Filling with analysis fluid
Control
CTU10xx: 1800 mm x 985 mm x 835 mm
CTU12xx: 1800 mm x 910 mm x 1140 mm
CTU10xx: ≈ 270 kg
≈ 290 kg with ultrasonic unit
CTU12xx: ≈ 310 kg
mobile (mounted on casters)
600 W (800 W with ultrasonic unit)
15 ... 28 °C
Polished stainless steel
via the analysis cabinet
PC controlled with user-friendly software, rinse
options and rinsing volume programmable
Storage and filtration module
Membrane holder
Vacuum nozzle
Diffuser
for Ø 47... 50 mm filter membranes
for faster filtration of the analysis fluid
For even distribution of analysis fluid over
membrane
operating pressure
- 0.8 ... 6 bar
Reservoir, test fluid
2x 20 l (1x storage reservoir, 1x suction reservoir)
Reservoir switch-over
Automatic
Filtration of analysis fluid
Fine filtration to ISO4406 min. ISO 12/9
Filter size, filtration rating
2x LF BN/HC 60, 3 µm (1xx0 series)
2x MRF-1-E/1, 1 µm (1xx1 series)
Built-in drip tray
25 litres with drain
To be provided by the operator (not included)
Compressed air
Pre-filtered (min. 5 µm) and dry compressed air,
max. 6 bar,
Air flow rate: 60 l/min,
Connection: Nipple DN 7.2
Supply voltage
according to order
Ultrasonic
100 W, 40 KHz
Basket for ultrasonic unit
Dimensions: 200 x 110 x 40 mm
Mesh width:
4 mm
E 7.959.3/12.11
Description
71
Dimensions
Model code
CTU 1 0 3 0 - M - Z - Z
CTU 10xx
Type
CTU = ContaminationTest Unit
Series
1 = 1000 Series
Size
0 =
2 =
dimensions of analysis cabinet (Clean Box):
300 mm x 768 mm x 365 mm
(height (approx.) x width x depth)
dimensions of analysis cabinet (Clean Box):
460 mm x 768 mm x 650 mm
(height (approx.) x width x depth)
Type
0 =
3 =
Version 2005
Version 2011
– Software ConTes
– 1 µm Filtration
– automatic pressure control
Analysis fluid
0 = solvent A III class
flash point > 60 °C, lower explosive limit > 0.6 Vol.%
1 = water with surfactants, permitted ph-values 6 ...10,
no deionized water
Supply voltage
K = 120 V AC / 60 Hz / 1 phase
M = 230 V AC / 50 Hz / 1 phase
N = 240 V AC / 50 Hz / 1 phase
O = 240 V AC / 50 Hz / 1 phase
P = 100 V AC / 50 Hz / 1 phase
CTU 12xx
USA / Canada
Europe
UK
Australia
Japan
Extraction method
Z = spray, medium pressure
U = spray, medium pressure with additional ultrasonic cleaning
Supplementary details
Z=standard
R = external rinsing connections Ø 6 mm, between glove holes
Blank values
All data is dependent on the ambient conditions
Environment
Clean room
Laboratory
Separate
sampling room
Factory building
CTU 1xxx
0.4 ... 0.6 mg
0.6 ... 1.0 mg
0.6 ... 1.2 mg
1.0 ... 1.4 mg
Cleaning time [h]
after brief
shutdown (≤ 24 h)
[µm]
100*
high
1.5 ... 4
150*
medium
1 ... 2
250*
low
0.5 ... 1.5
* applies to a maximum membrane load of 0.8 mg
E 7.959.3/12.11
Max. particle size
72
Time and
effort
NOTE
Cleaning time [h]
after extended
shutdown (≥ 24 h)
3 ... 5
2 ... 4
1 ... 3
The information in this brochure
relates to the operating conditions and
applications described.
For applications and operating
conditions not described, please contact
the relevant technical department.
Subject to technical modifications.
HYDAC Filter Systems GmbH
Industriegebiet
D-66280 Sulzbach / Saar
Tel.:+49 (0) 6897/509-01
Fax:+49 (0) 6897/509-846
Internet: www.hydac.com
E-Mail: filtersystems@hydac.com