7100SZ Series SafeZone™ Installation and Instruction Manual Patent Pending 80-9371-0081-020 (10-10) Pull Side Applications with Slide Track (7110SZ, 7150SZ) (see page 5 for template) 2 3 1 Push Side Applications with Double Lever Arms (7120SZ, 7130SZ) (see page 3 for template) 4 Item No. Description 1 Track 2 3 4 Cover Arm (Pull Side) Double Lever Arm (Push Side) Requirements: ! ! ! ! ! ! ! ! ! Units are handed. Hand of unit and hand of door must be the same. Door must be hung on ball bearing butt hinges or ¾” (19) offset pivots. Door thickness must be 1¾” (44) minimum 2¼” (64) maximum. Door must swing freely through the entire opening and closing cycle before beginning the installation procedure. Frame face must be a minimum of 2” (51). Ceiling clearance must be a minimum of 4” (102). Power input to unit must be of the same voltage as that stated on the unit. Unit to be mounted on interior of building in dry environment, maximum humidity of 95%. See NFPA70 for wiring requirements and NFPA72 for alarm system requirements. Component Layout Backplate Closer/Holder Unit Assembly Preparation for Fasteners Sensor Hook-up Board Fasteners Test Switch Access Tube Door or Frame 1/4” - 20 machine screw Hollow Metal Standard Sleeve nuts and bolts Backplate Mtg Screw (5) Metal Optional Through-bolts and grommet-nuts Drill-Sizes Drill: #7 (0.201” dia.) Tap: 1/4” - 20 9/32” (7 mm) through; 3/8” (9.5 mm) door face opposite to closer Aluminum 3/8” (9.5 mm) through or Wood 9/32” (7 mm); 3/8” (9.5 mm) dia. x All 3/8” (9.5 mm) deep on door opposite to closer Cover Mtg Screw (3) Cover Included with 7110SZ and 7150SZ Included with 7120SZ and 7130SZ 7110 Main Arm (7210-1A) 7150 Main Arm, Handed (7250-1L, 7250-1R) 7130 Arm Assembly (7701-1B) Slide Track (7200-1T) Arm Screw (7701-MAS) Screw & Washer 7120 Arm Assembly (7701-1A) Slide Assembly (7700SLD) Track Mtg Screw (3) NOTE: Optional remote for Advanced Settings (sensitivity, door control mode) if required. (7100REM) Certifications UL228 UL10B Page 2 80-9371-0081-020 (10-10) Ceiling Line 7120SZ, 7130SZ Use of an auxiliary door stop, by others, is suggested, but is required for doors opening beyond 110°. 3-1/2 Min (89) Double Lever Arm (Push Side) 2 Min (51) Hinge Edge RH - Right Hand Door LHR - Left Hand Reverse 1 Left Hand Door - LH Right Hand Reverse - RHR Drill #7; Tap 1/4-20 19-3/16 (487) 4 (102) 11-3/8 (289) 8-11/16 (221) 5/16 11/16 (8) (17) 4-1/8 (105) A For Concealed WiringOnly 7/8 (22) 2 DIA THRU For Concealed Wired Only (If surface wired, go to Step 3.) 7-1/2 (191) 1-3/4 (44) 1-5/8 (41) Left hand door shown, right hand opposite. C All dimensions shown in inches (mm). Hinge or Pivot DOOR OPENING ANGLE To 100° 100° to 180° Dimension “A” Inches (mm) 5-7/8 3-1/8 150 80 3 6 5 4 L R Y S Arm Mark Main Arm Z Arm Pinion Screw Flat (7/16” Drive) Page 3 80-9371-0081-020 (10-10) 8 7 90° Closing Force 11/16” Drive + 9 Latch Product shipped with closing force set at the middle of the power range. 11/16" Drive Backcheck Sweep 1/8” wrench provided Backcheck Strength ! Backcheck Positioning (75° - 95°) 10 Caution: Do not completely close backcheck valve. MAKE ELECTRICAL CONNECTIONS: • Power input to unit must be of the same voltage as that listed on the label. • All wiring connections use standard wiring practice conforming to local wiring codes. • Maximum wire size is 18AWG. • Make input power connections to the hook-up board terminal strip using illustrations. 24V AC/DC INPUT CIRCUIT BOARD 120V AC INPUT CIRCUIT BOARD Test Switch Fuse Fuse Test Switch PTO125V (125V / 1/2A) PTO125V (125V / 1/2A) Solenoid Connection 24V AC/DC Power Input 11 ! Caution: Determine proper control board; 24V or 120V. Safe Zone Sensor Connection 120V AC Power Input Solenoid Connection Safe Zone Sensor Connection 12 Adjust settings Page 4 80-9371-0081-020 (10-10) Ceiling Line 7110SZ, 7150SZ Use of an auxiliary door stop, by others, is suggested, but is required for doors opening beyond 110°. 4 Min (102) Track Mount (Pull Side) 2 Min (51) RH - Right Hand Door LHR - Left Hand Reverse 1 Drill #7; Tap 1/4-20 4 (102) 3-1/4 (83) Left Hand Door - LH Right Hand Reverse - RHR 19-3/16 (487) 11-3/8 (289) 4-1/8 (105) 8-11/16 (221) 1-1/16 1-3/8 (27) (35) For Concealed Wiring Only 7/8 (22) DIA THRU For Concealed Wired Only (If surface wired, go to Step 3.) Track Mount Unit 4 (102) 1-3/16 (30) 11 (279) ! Right hand door shown, left hand opposite. ! All dimensions shown in inches (mm). 22 (559) C 2 Hinge or Pivot 3 4 Fully close Latch and Sweep Valves with 1/8" wrench provided. 5 6 Arm Indexing RIGHT HAND Use main arm to rotate pinion until flat is visible. RE-INSTALL HERE LEFT HAND PINION FLAT Page 5 80-9371-0081-020 (10-10) 7 9 8 Arm Stud Slide Assembly 1 Arm Washer Arm Screw Open Latch & Sweep Valves Main Arm with 1/8” wrench provided. 2 10 11 Closing Force ! Caution: Do not completely close backcheck valve 1/8” wrench provided Latch + 12 11/16” Drive Sweep Backcheck Strength Backcheck Positioning (75° - 95°) Product shipped with closing force set at the middle of the power range. MAKE ELECTRICAL CONNECTIONS: • Power input to unit must be of the same voltage as that listed on the label. • All wiring connections use standard wiring practice conforming to local wiring codes. • Maximum wire size is 18AWG. • Make input power connections to the hook-up board terminal strip using illustrations. 24V AC/DC INPUT CIRCUIT BOARD Fuse Fuse Caution: Determine proper control board; 24V or 120V. Test Switch PTO125V (125V / 1/2A) PTO125V (125V / 1/2A) Solenoid Connection 13 ! 120V AC INPUT CIRCUIT BOARD Test Switch 24V AC/DC Power Input Backcheck Safe Zone Sensor Connection 120V AC Power Input Solenoid Connection Safe Zone Sensor Connection 14 Adjust settings Page 6 80-9371-0081-020 (10-10) SafeZone™ Set-Up Sensor Technical Specifications DESCRIPTION SPECIFICATION Frequency: Supply voltage: 24.125 GHz 12 to 24 V AC: ± 10%: 12 to 24 V DC: -10% / +30%: Normal: 7’; Maximum: 10’-0” 0° to 90° vertical -15° to +15° lateral Mounting height: Tilt angle: Detection area: Wide Narrow Minimum detection speed: Power consumption: Standard output relay: Max contact voltage Max contact current Max switching power Hold time: Temperature range: Dimensions: Weight: Material: 13ft (W) x 6.5ft (D) 6.5ft (W) x 8.2ft (D) (supplied as optional) 2 in/sec. (measured in axis) <2W 60 VDC / 125 VAC 1 A (resistive) 30W (DC) / 60VA (AC) 0.5 sec. to 9 sec. (adjustable) -4°F to 131°F 4.75in (W) x 3.15in (H) x 2.0in (D) 0.5lbs ABS Safety Precautions • • • • • • Shut off all power going to the header before attempting any wiring procedures. Maintain a clean & safe environment when working in public areas. Constantly be aware of pedestrian traffic around the door area. Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door. Always check placement of all wiring and components before powering up to insure that moving door parts will not catch any wires and cause damage to equipment. Ensure compliance with all applicable safety standards upon completion of installation. ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS Circuit board components are vulnerable to damage by electrostatic discharge (ESD). ESD can cause immediate or subtle damage to sensitive electronic parts. An electrostatic charge can build up on the human body and then discharge when you touch a board. A discharge can be produced when walking across a carpet and touching a board, for example. Before handling any board, make sure you dissipate your body’s charge. CAUTION: In the event a unit needs to be opened, observe the following precautions. Ground yourself by touching a conductive surface of the door or other element connected to common earth ground to discharge the static electricity present in your body. Avoid walking around while replacing items inside the case, especially if you are on carpet or during conditions of low temperature and low humidity. Handle the board by the edges only to avoid touching electronic components. Store a loose board in an anti-static bag. Page 7 80-9371-0081-020 (10-10) Mechanical Adjustments THE POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL AND LATERAL ANGLE OF THE ANTENNA B A C -30º 0º 45º 30º Sensing field as close to the door as possible: -antenna set at the position of 0° Sensing field close to the door: -antenna set at the position of 30° Sensing field far from the door: -antenna set at the position of 45° Set Up + Press to increase hold open setting (see table below). Hold open time refers to the time the door will remain open AFTER movement is no longer detected. Hold open time can be adjusted manually by means of the push buttons + (more) and - (less). Setting 0 1 2 3 4 5 (Default) 6 7 8 9 Time (Seconds) 0.5 5 6 7 8 10 14 16 18 20 +30 - Press to decrease hold open setting. Pressing the two push buttons, located on the circuit board, simultaneously for three seconds, will restore all default settings. Recommended Settings: Setting 1-3 Setting 4-6 Setting 7-9 Troubleshooting SYMPTOMS PROBABLE CAUSE Red LED does not light up. The sensor power is off. Check the wiring and power supply. Cable is not connected. Connect cable. CORRECTIVE ACTION ASSA ABLOY Norton ® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Safe Zone™ is a trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2010 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Page 8 3000 Highway 74 East Monroe, NC 28112 Tel: (877)-974-2255 Fax: (800)-338-0965 www.nor tondoorcontrols.com 80-9371-0081-020 (10-10)