85N Extension Kits SE ASE

advertisement
Page 1 of 2
INSTALLATION
INSTRUCTIONS
Extension Kits
(SE and ASE)
Fixture Type
Wall/Slot 85N
P/C 510156-3000
Do not modify or alter this product in any way, or install in any fashion which is contrary to the instructions contained herein.
If you have any questions regarding this product or the installation of it, please call Litecontrol Engineering at 781-294-0100.
Top View - Straight Extension (SE)
Ceiling Opening
Top View - Angled Straight Extension (ASE)
Ceiling Opening
Wall Reference
Wall Reference
Dim "X"
Last Fixture
in Row
Support Rail
Dim "X"
Support Rail
1
Support Rail
7/8" K.O.
Instructions:
1.a. Measure ceiling opening (Dim. “X”) and cut
gasket strip to match Dim. “X”. Peel off
adhesive backing and apply to support rail.
b. Snap plug button into 7/8" diameter hole in
end header.
NOTE: Do not route flex feed thru end header or it
may interfere with installation of filler plate.
Plug Button
End Header
Wall Angle (if required)
U-Clip
2
3. If the dimension from the top of fixture to bottom
of shield is less than 10 1/2", remove square K.O.s
in slots of extension shield. Remove only the
K.O.s required for correct height and adjustment.
Each K.O. removed allows for 1/4" deduction
in height.
3
Side Leg
Jointer Strap
Dim "X"
minus 1/16"
Last Fixture in Row
Gasket
Strip
2.a. Trim side legs to a length of Dim. “X” minus 1/16".
b. Slide joiner strap inside U-angle frame and press U-clips
over both pieces until seated (typical both side legs).
Trimmed Leg
Shield
Shield
NOTE: Be sure the shield on the last fixture in row
is not installed at this time.
Straight leg faces out
Last Fixture
in Row
Needle Nose Pliers
Extension Shield
Side Legs
U-angle Frame
Square K.O.s
100 Hawks Avenue Hanson, MA 02341 781 294 0100 litecontrol.com
date rev. 04/12/2011
Page 2 of 2
INSTALLATION
INSTRUCTIONS
Extension Kits
(SE and ASE)
Fixture Type
Wall/Slot 85N
P/C 510156-3000
Do not modify or alter this product in any way, or install in any fashion which is contrary to the instructions contained herein.
If you have any questions regarding this product or the installation of it, please call Litecontrol Engineering at 781-294-0100.
4.a. Attach U-angle Assembly to fixture end header with
(2) No. 8 x 3/8" long screws and nuts.
4
Dart
Fastener
b. Insert (2) No. 8 screws (by others) thru holes in
U-angles and into wall opposite end header.
Support Rail
No. 8 Wall Mounting
Screws (by others)
Note: Make sure frame is level.
c. Insert plastic dart fasteners into bottom row
of holes on wall side of U-angle frame.
5. Insert straight
extension shield
into end of row
fixture shield.
5
Extension Shield
6.a. Lift fixture shield
in behind end of
row fixture so that
shield mounting
screws protrude
into housing slots.
Secure with washers
and wing nuts provided
with fixture shields.
U-angle
Assembly
No. 8 x 3/8" screws
and nuts
End of Row
Fixture Shield
Dim "X"
6
b. Slide extension shield to wall and secure to
U-angle with dart fasteners.
c. Trim length of filler plate to
Dim “X” minus 3/8".
d. Lift and shift filler plate into opening
and rest on bottom flanges of U-angle.
For “R” and “F” position diffusers
1. Trim a piece of wall angle to DIM “X”. (Wall
angle is shipped separately in 96" lengths.)
Filler Plate
U-angle Frame
Extension
Shield
strap to Dim “X”. Peel off backing on (1) side of
tape and apply to hole side of angle.
3. Peel off opposite backing on strap and apply
diffuser angle to extension shield at same height
as fixture shield angle. (Be sure to apply pressure
along the entire length of the angle to ensure
adhesive contact.)
Trimmed off
Surface
End of Row
Fixture
Dart
Fastener
Fixture Shield
2. Cut length of 1/32" thick adhesive-backed tape
End of Row
Fixture
Wall Angle
(if required)
Shield Mounting
Screws
1/32" Thick
Adhesive-backed
Tape
100 Hawks Avenue Hanson, MA 02341 781 294 0100 litecontrol.com
date rev. 04/12/2011
Download