SUMMARY DATA SHEET State Route: 0286, Segment 1010, Offset 1617 Section: 402 Station: 687 + 00 County: Indiana Township: Montgomery Stream: Branch of Cush Creek Drainage Area: 1.53 square miles Project Location: Latitude: Longitude: USGS Quads: Rochester Mills, Burnside, Commodore, and Barnesboro N 40º 45’ 32” W 78º 52’ 2” Average Existing Stream Channel Dimensions: Top Width: 9’ – 0” Bottom Width: 9’ – 0” Flow Depth of Existing Stream: 6” to 3’ (supercritical flow & subcritical flow) Stream Bed Elevation: 225 ft Upstream: 1573.35 feet 225 ft Downstream: 1569.46 feet Water Surface Elevation: 225 ft Upstream: 1579.34 feet 225 ft Downstream: 1571.84 feet pH: 7.1 Existing Structure: Type: Reinforced Concrete CIP Slab Span: 8’ – 0” Width: 37’-0” (curb to curb) perpendicular to the centerline of the roadway Skew: 60 Nearest Upstream Structure: 5 foot Concrete pipe carrying a private driveway entrance roadway over the Branch of Cush Creek. Nearest Downstream Structure: There is no downstream structure over the Branch of Cush Creek Proposed Structure: Type: Precast reinforced concrete box culvert No. of Cells: 1 Clear span: 9’ – 0” Width: 45’-0 3/8” (curb to curb) measured along the skew angle Length: 36’-0” (curb to curb) measured perpendicular to roadway 2 - 12’ lanes + 2 - 6’ shoulders Height: 8’ – 0” (7’ – 0” effective) Skew: 60 Channel: Type: Natural streambed Bottom width: 9 feet Approximate side slopes: 0:1 Application Type:______Standard__________________________ Wetlands Impact: Rip-rap size: Wetlands are present for this project. For Q25: Vchannel = 8.56 ft/sec (HEC-RAS output for 25-year storm) Because culverts do not require scour calculations, the velocity is not multiplied by a safety factor. The velocity will not be factored for the stream banks either. The velocity for Q25 is greater than the velocity for Q100, therefore the Q25 velocity was used. As per Design Manual, Part 4, Section 7.2.5, rip-rap size should be R-6 or larger. Details are available in Appendix D of this report. HW is defined as the difference between the water surface elevation and the streambed elevation at the upstream section. D is the effective height of the culvert. The value of HW/D should be less than 1.5 to 2.0, as per Design Manual, Part 2. See Appendix D for the calculations performed to determine the HW/D values. (HW/D)25 = 0.76 (HW/D)100 = 0.94