NZQA registered unit standard 17429 version 4 Page 1 of 4 Title Operate vents and drains from a thermal electricity generation control room Level 4 Credits 4 Purpose People credited with this unit standard are able to: demonstrate knowledge of vent and drain controls and operation; operate and monitor vents and drains; and identify and respond to deviations in vent and drain operations. Classification Electricity Supply > Electricity Supply - Thermal Operations and Control Available grade Achieved Entry information Recommended skills and knowledge National Certificate in Energy and Chemical Plant (Process Operation) with optional strands in Steam Generation; Turbine Operations; Waste Treatment; Refrigeration; Chemical Continuous Process; Chemical Batch Process; Solid Handling; Petrochemical Field Operations; Petrochemical Control Room Operations; Petrochemical Production Storage; Kraft Cycle Operations; Kraft Bleach and Chemical Operations; and Kraft Pulping and Chemical Plant [Ref: 1344]; and National Certificate in Electricity Supply (Thermal Operator) (Level 4) with strands in Thermal Operations, Combined Cycle Operations, and Geothermal Operations [Ref: 0894]; or demonstrate equivalent knowledge and skills. Explanatory notes 1 This unit standard is intended for, but not restricted to, workplace assessment. The range statements within the unit standard can be applied according to industry specific equipment, procedures and processes. 2 Safety of personnel and plant must be a priority throughout the assessment. If the safety requirements are not met the assessment must stop. Electricity Supply Industry Training Organisation SSB Code 101813 New Zealand Qualifications Authority 2016 NZQA registered unit standard 17429 version 4 Page 2 of 4 3 Performance and work practices in relation to the outcomes and evidence requirements must comply with all current legislation, especially the Electricity Act 1992, and any regulations and codes of practice recognised under that statute; the Health and Safety in Employment Act 1992; and the Resource Management Act 1991. Electricity supply industry codes of practice and documented industry procedures include the current version of the Safety Manual – Electricity Industry (SM-EI) Wellington: Electricity Engineers’ Association. A full list of current legislation and industry codes is available from the Electricity Supply Industry Training Organisation, PO Box 1245, Hamilton 3240. 4 The phrase in accordance with industry requirements is implicit in all outcomes and evidence requirements in this unit standard. 5 Industry requirements include all asset owner requirements; manufacturers’ specifications; and enterprise requirements which cover the documented workplace policies, procedures, specifications, business, and quality management requirements relevant to the workplace in which assessment is carried out. 6 The term operate is defined as the remote operation, testing and commissioning of main and auxiliary thermal plant systems associated with large steam/electrical generation plant from a control room environment. Outcomes and evidence requirements Outcome 1 Demonstrate knowledge of vent and drain controls and operation. Evidence requirements 1.1 Boiler vent and drain operation is described. Range 1.2 include all that apply – header vents and drains, drum vents and drains, vessels, tanks, pits, effluent treatment. Turbine drain operation is described. Range include all that apply – drains indication, saturation temperature, vessels, tanks, pits, ‘master and martyr’ sequence, water ingress protection systems. Outcome 2 Operate and monitor vents and drains. Evidence requirements 2.1 Current status of plant is identified. 2.2 Operations are carried out. Electricity Supply Industry Training Organisation SSB Code 101813 New Zealand Qualifications Authority 2016 NZQA registered unit standard 17429 version 4 Page 3 of 4 2.3 Actions are logged. 2.4 Operating decisions are determined in accordance with plant status. include all that apply – plant availability and service condition, resource consent and loading limits, impact on operations. Range 2.5 Plant and equipment are monitored. Outcome 3 Identify and respond to deviations in vent and drain operations. Evidence requirements 3.1 Deviations from normal operating conditions are identified, reported and explained. include all that apply – sequence problems, drains temperature excursions including vessel, tank and pit; thermocouple failure, pressure/temperature excursions. Range 3.2 Plant safety procedures are followed. Planned review date 31 December 2015 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment Registration 1 23 October 2001 N/A Revision 2 11 February 2004 N/A Rollover and Revision 3 25 June 2007 N/A Review 4 9 December 2010 N/A Accreditation and Moderation Action Plan (AMAP) reference 0120 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Please note Providers must be granted consent to assess against standards (accredited) by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be granted consent to assess against standards by NZQA before they can register credits from assessment against unit standards. Electricity Supply Industry Training Organisation SSB Code 101813 New Zealand Qualifications Authority 2016 NZQA registered unit standard 17429 version 4 Page 4 of 4 Providers and Industry Training Organisations, which have been granted consent and which are assessing against unit standards must engage with the moderation system that applies to those standards. Consent requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the Electricity Supply Industry Training Organisation info@esito.org.nz if you wish to suggest changes to the content of this unit standard. Electricity Supply Industry Training Organisation SSB Code 101813 New Zealand Qualifications Authority 2016