IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING IEC 60384-22:2004-06, Edition 1.0 Fixed capacitors for use in electronic equipmentPart 22: Sectional specification: Fixed surface mount multilayer capacitors of ceramic dielectric, Class 2 R=Required by Lab S=May be subcontracted 3PPS=Three Phase Power Supply required Clause 4.4 4.5.1 4.5.2 4.5.3 4.5.4 Measurement/testing Visual examination and check of the dimension Capacitance Tangent of loos angle Insulation resistance Voltage proof 4.15 4.9 4.16 4.5.5 Robustness of termination Resistance to soldering heat Component solvent resistance1) Impedance1) July 2009 Testing / measuring equipment / material needed Sliding gauge Capacitance meter 50Hz to 10MHz Capacitance meter 50Hz to 10MHz Insulation resistance meter, max. DC 100V AC/DC High voltage tester, max. 5KV Voltage measurement instrument Mechanical testing equipment Solder bath (230°C to 350°C) Solvent AC power supply Voltage measurement instrument Current measurement instrument 1/2 Subcontracting R R R R R R R R R IEC 60384-22, ed 1 IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause 4.5.6 1) Measurement/testing Equivalent series resistance[ESR]1) 4.10 4.17 4.8 4.3 4.7 4.11 4.12 4.13 4.14 4.18 Solderability Solvent resistance of the marking1) Substrate bending test Mounting Shear test Rapid change of temperature Climatic sequence Damp heat, steady state Endurance Accelerated damp heat, steady state1) 4.6 Temperature coefficient and temperature cycle drift COMMITTEE OF TESTING LABORATORIES Testing / measuring equipment / material needed AC power supply Voltage measurement instrument Current measurement instrument Solder bath (230°C to 350°C) Solvent, Cotton wool Substrate bending equipment Mounting facilities Mechanical testing equipment Temperature change test chamber Climatic test chamber for simulation of temperature and humidity Climatic chamber 40°C ± 2°C 93%±3% RH DC power supply (max.1000V); Temperature chamber Climatic Chamber (85°C± 2°C 85% 3% RH); AC/DC Power supply Insulation resistance meter Temperature change test camber; Capacitance meter 50Hz to 10MHz Subcontracting R R R R R R R R R R R R If required in the detail specification. July 2009 2/2 IEC 60384-22, ed 1