List of test equipment for IEC 60950 3rd ed.

advertisement
IEC SYSTEM FOR CONFIRMITY TESTING
AND CERTIFICATION OF ELECTRICAL
EQUIPMENT
COMMITTEE OF TESTING LABORATORIES
TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC 60384-22:2004-06, Edition 1.0
Fixed capacitors for use in electronic equipmentPart 22: Sectional specification:
Fixed surface mount multilayer capacitors of ceramic dielectric, Class 2
R=Required by Lab
S=May be subcontracted
3PPS=Three Phase Power Supply required
Clause
4.4
4.5.1
4.5.2
4.5.3
4.5.4
Measurement/testing
Visual examination and check of the
dimension
Capacitance
Tangent of loos angle
Insulation resistance
Voltage proof
4.15
4.9
4.16
4.5.5
Robustness of termination
Resistance to soldering heat
Component solvent resistance1)
Impedance1)
July 2009
Testing / measuring equipment / material needed
Sliding gauge
Capacitance meter 50Hz to 10MHz
Capacitance meter 50Hz to 10MHz
Insulation resistance meter, max. DC 100V
AC/DC High voltage tester, max. 5KV
Voltage measurement instrument
Mechanical testing equipment
Solder bath (230°C to 350°C)
Solvent
AC power supply
Voltage measurement instrument
Current measurement instrument
1/2
Subcontracting
R
R
R
R
R
R
R
R
R
IEC 60384-22, ed 1
IEC SYSTEM FOR CONFIRMITY TESTING
AND CERTIFICATION OF ELECTRICAL
EQUIPMENT
Clause
4.5.6
1)
Measurement/testing
Equivalent series resistance[ESR]1)
4.10
4.17
4.8
4.3
4.7
4.11
4.12
4.13
4.14
4.18
Solderability
Solvent resistance of the marking1)
Substrate bending test
Mounting
Shear test
Rapid change of temperature
Climatic sequence
Damp heat, steady state
Endurance
Accelerated damp heat, steady state1)
4.6
Temperature coefficient and temperature
cycle drift
COMMITTEE OF TESTING LABORATORIES
Testing / measuring equipment / material needed
AC power supply
Voltage measurement instrument
Current measurement instrument
Solder bath (230°C to 350°C)
Solvent, Cotton wool
Substrate bending equipment
Mounting facilities
Mechanical testing equipment
Temperature change test chamber
Climatic test chamber for simulation of temperature and humidity
Climatic chamber 40°C ± 2°C 93%±3% RH
DC power supply (max.1000V); Temperature chamber
Climatic Chamber (85°C± 2°C 85% 3% RH);
AC/DC Power supply
Insulation resistance meter
Temperature change test camber;
Capacitance meter 50Hz to 10MHz
Subcontracting
R
R
R
R
R
R
R
R
R
R
R
R
If required in the detail specification.