List of test equipment for IEC 60950 3rd ed.

advertisement
IEC SYSTEM FOR CONFIRMITY TESTING
AND CERTIFICATION OF ELECTRICAL
EQUIPMENT
COMMITTEE OF TESTING LABORATORIES
TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC 60384-6:2005-09, Edition 3.0
Fixed capacitors for use in electronic equipmentPart 6: Sectional specificationFixed metallized polycarbonate film dielectric d.c. capacitors
R=Required by Lab
S=May be subcontracted
3PPS=Three Phase Power Supply required
Clause
4.1
4.2.1
4.2.2
4.2.3
4.2.4
4.3
4.4
4.14
4.5
4.15
4.6
4.7
4.8 or 4.91)
July 2009
Measurement/testing
Visual examination and check of the
dimension
Voltage proof
Capacitance
Tangent of loos angle
Insulation resistance
Robustness of terminations
Resistance to soldering heat
Component solvent resistance
Solderability
Solvent resistance of the marking
Rapid change of temperature
Vibration
Bump or shock
Testing / measuring equipment / material needed
Sliding gauge
AC/DC High voltage tester, max. 5KV
Voltage measurement instrument
Capacitance meter 50Hz to 10MHz
Capacitance meter 50Hz to 10MHz
Insulation resistance meter, max. DC 100V
Mechanical testing facilities
Solder bath (230°C to 350°C)
Solvent
Solder bath (230°C to 350°C)
Solvent, Cotton wool
Temperature change test chamber
Vibration test system
Shock test machine
1/2
Subcontracting
R
R
R
R
R
R
R
R
R
R
R
R
R
IEC 60384-6, ed 3
IEC SYSTEM FOR CONFIRMITY TESTING
AND CERTIFICATION OF ELECTRICAL
EQUIPMENT
Clause
4.10
4.11
4.12
4.2.51)
4.13
1)
Measurement/testing
Climatic sequence
Damp heat, steady state
Endurance
Characteristics depending on temperature
Charge and discharge
COMMITTEE OF TESTING LABORATORIES
Testing / measuring equipment / material needed
Climatic test chamber for simulation of temperature and humidity
Climatic chamber 40°C ± 2°C 93%±3% RH
DC power supply (max.1000V); Oven (max 150°C)
Climatic test chamber for simulation of temperature -55°C to 125°C
Capacitance meter 50Hz to 10MHz
Charge and discharge test circuit
Subcontracting
R
R
R
R
R
If required in the detail specification.
July 2009
2/2