New Design Baxi Heating UK Ltd Brooks House Coventry Road Warwick CV34 4LL Tel: 08448 711538 Fax: 08448 711537 Email: newdesign@bdrthermea.com Full Project Information Checklist Completed Design Request Form Plans for all house types Sections for all house types Elevations for all house types Complete SAP data (if applicable) *If all the above information is not received, designs may be subject to delays. Application for Heating System Designs BDR Thermea Specification is pleased to offer to Builders, Developers and Housing Associations a fully indemnified heating design service for domestic properties (subject to minimum numbers) for BDR Thermea products only. We are happy to offer advice on compliance with the latest regulations such as the Code for Sustainable Homes and the building regulations. Project Information Client /Developer: Address: Contact Name: Tel: Email address: Site Address: No. of plots: Site commencing date: Baxi local representative (if known): On completion, all designs will be sent to the email address provided above. 1 of 5 PLEASE NOTE: It is vital that all information boxes where possible in this form, are completed to enable us to commence design with out delay. Plans, sections, elevations/window schedules and site plans (where applicable) must accompany all job requests. Until full and final information is received, jobs may be placed on hold which may result in the delay of completed designs. Hard copy/PDF plans at a scale of 1:50 or AutoCAD should be submitted with this request form. Maximum property size for a design is 450 sq. metres. New Design will not carry out designs on refurbishment properties, unless all U values are clearly defined. If applicable, please provide housing association specification. 1. Design Parameters Site water pressure bar. Please attach copy of 7 day trace. Designs will be based on average ‘U’ values as stated in Building Regulations L1A 2010, as shown in Table 2 below. Should you require different ‘U’ values, please amend Table 2, below: Table 2 – ‘U’ Values Baxi recommended External Walls Internal Walls Floors Doors Windows Roof 0.30 0.60 0.25 2.00 2.00 0.20 If alternative values required, please complete below: External Walls Internal Walls Floors Doors Windows Roof Room temperatures and air change rates will be in accordance with NHBC guidelines and BS 5449. Should you require different room temperatures and air changes, please amend table 3, below: Table 3 – Temperatures & Air Changes Baxi recommended If alternative values required, please complete below Room Type Temp. Air Change Room Type Temp. Air Change (°C) (°C) Living Areas 21 1.5 a/c/h Living Areas Hall & Landing 18 1.5 a/c/h Hall & Landing Bathrooms 22 2.0 a/c/h Bathrooms Kitchen/Utility 18 2.0 a/c/h Kitchen/Utility Bedrooms 18 1.0 a/c/h Bedrooms All designs will be prepared to an external temperature of -3°C. 2 of 5 2. Products to be specified (Designs will be completed for Baxi Group Products only) Please fill in Table 4 below, on system product choice. Table 4 – Product Specification Fuel Type Boiler Type SAP Beneficial Accessories Solar System Boiler Model Cylinder Elson Products Radiator Manufacturer Natural Gas Heat Only GasSaver Electric System Heatsaver Baxi Potterton Megaflo Eco Elson Aquanox LPG PremierPlus Elson Packages Biomass Combi* Other: Other: Promax Store System (default is Myson Premier) Towel Rail Manufacturer Towel Rail Type Chrome White Curved TRV Valves Controls Manufacturer Heating to all properties will have 2 zones according to current regulations (except bedsits) unless stated here: Please note: If shower details are not given a flow rate of 12 l/m will be assumed in accordance with BS EN 806 * When sizing combi boiler we will assume ensuite(s) to have an electric shower, unless otherwise stated in the special notes section below. 3. System data Please tick preferences below Table 5 – System Data System Details Heating System Design System Type Pipe work Type Connection size to radiators Pipe work drops Pipe work orientation (flats) Underfloor Heating (if applicable)* Please indicate preference: Sealed Open-vented Manifold 2 Pipe system Copper Plastic 10mm 15mm Behind dry liner Surface mounted Celing void Ducted in screed Ground Floor Whole house *Underfloor heating control by others Note: If an external water point is desired please indicate the preferred location on drawing. 3 of 5 4. Special building allowance Examples: Allowance made for internal wall, knock out panels. Life time homes. Grey Water Recycling DDA compliant Please detail any special notes and requirements: 5. General Information Completion date after receiving full and final design request form, will be approx 4 weeks plus. Quantity and position of radiators will be designed in accordance with BS 5449: 1990, and best practice. Where radiators are indicated on developers drawing these will be adhered to where practicable. Radiators must not be positioned behind doors as this affects the heat distribution to the room in question. This may cause the indemnity to become invalid for this room. Room thermostat(s) position needs to be suitably located. We do not indicate G3 discharge point on our drawings. We reserve the right to charge for revision work in the event of building layout changes, design parameter changes or alterations to positions of heating system components. Designs are indicative only. Very minor alterations may not be undertaken 4 of 5 6. Alternative Technologies HeatSaver The Multifit HeatSaver is a package including a Multifit GasSaver and a 50 litre temporal store, designed for installation with a Baxi or Potterton HE combi boiler. Where high flow rates are not required in smaller properties, this package delivers SAP benfits up to 8% using SAP 2009. The Multifit HeatSaver Advance package includes a 40kW Baxi Duo-tec Combi boiler, a Multifit GasSaver and a 50 litre temporal store. This package offers flow rates of 18l/min capable of satisfying multi bathroom properties. This matches the hot water performance of a system boiler with a 200 litre unvented cylinder, while using 25% less gas, also delivering SAP benefits. GasSaver The Multifit GasSaver is an innovative product that sits neatly between a boiler and flue and recycles the heat from the flue gases which would normally be expelled into the atmosphere and wasted. It has been proven by independent testing to achieve domestic hot water savings of up to 7% and can reduce the gas used to heat hot water by up to 37% annually and a SAP benefit of approx. 5%. Solar Hot Water There may be occasions, were the cylinder cupboard, may not be large enough to accommodate the solar cylinder as well as the solar pump station, expansion vessels, etc. The pump station and expansion vessels can be repositioned to the roof space, in order to free up space in the cylinder cupboard. Consideration must be given to the position of the solar panel / tubes. Unless a suitable drawing is submitted in AutoCAD format. A drawing register will be used to specify panel(s) orientation. Biomass boiler (Pellet or log type). Position of the biomass boiler must be considered, due to their physical size. Allowance must be made, for storage of either pellets or logs, dependent on boiler installed. Allowance must be made, for floor space, for buffer tank(s) 600 litre ( 900mm diameter x 1670mm high ), or 800 litre ( 990 mm diameter x 1700mm high ). Boiler back end protection, this is a requirement for our Baxi biomass boilers. The use of our thermostatic pump blending valve is a must. Boiler flues by others. Ecogen boiler Only approved engineers are allowed to install the Ecogen micro CHP boiler. Due to the weight Ecogen boiler will need to be fitted on to a suitably supported wall. 5 of 5