Appendix S1, auxiliary material U/Th–Pb LA-ICPMS geochronology at the Senckenberg Naturhistorische Sammlungen, Dresden Zircons were analyzed for U, Th, and Pb isotopes by LA-ICPMS techniques using a ThermoScientific Element 2 XR sector field ICP-MS coupled to a New Wave UP-193 Excimer Laser System. A teardrop-shaped, low volume laser cell constructed by Ben Jähne (Dresden) and Axel Gerdes (Frankfurt/M.) was used to enable sequential sampling of heterogeneous grains (e.g., growth zones) during time resolved data acquisition. Each analysis consisted of approximately 15 s background acquisition followed by 30 s data acquisition, using a laser spot-size of 25 and 35 µm, respectively. A common-Pb correction based on the interferenceand background-corrected 204 Pb signal and a model Pb composition [Stacey and Kramers, 1975] was carried out if necessary. The necessity of the correction is judged on whether the corrected 207 Pb/206Pb lies outside of the internal errors of the measured ratios. Discordant analyses were generally interpreted with care. Raw data were corrected for background signal, common Pb, laser induced elemental fractionation, instrumental mass discrimination, and time-dependant elemental fractionation of Pb/Th and Pb/U using an Excel® spreadsheet program developed by Axel Gerdes (Institute of Geosciences, Johann Wolfgang GoetheUniversity Frankfurt, Frankfurt am Main, Germany). Reported uncertainties were propagated by quadratic addition of the external reproducibility obtained from the standard zircon GJ-1 (~0.6% and 0.5-1% for the 207 Pb/206Pb and 206 Pb/238U, respectively) during individual analytical sessions and the within-run precision of each analysis. Further details of the instruments settings are available in Table S1. For further details on analytical protocol and data processing see Gerdes and Zeh [2006]. The uncertainty in the degree of concordance of Precambrian–Palaeozoic grains dated by the LA-ICPMS method is relatively large and results obtained from just a single analysis have to be interpreted with care. A typical uncertainty of 2–3% (2σ) in 207 Pb/206Pb for a Late Neoproterozoic grain (e.g., 560 Ma) relates to an absolute error on the 207 Pb/206Pb age of 45– 65 Myr. Such a result gives space for interpretation of concordance or slight discordance. The latter one could be caused by episodic lead loss, fractionation, or infiltration Pb isotopes by a fluid or on micro-cracks. Thus, zircons showing a degree of concordance in the range of 90– 110 % in this paper are classified as concordant because of the overlap of the error ellipse with the concordia [e.g., Linnemann et al., 2011]. Th/U ratios are obtained from the LA-ICP-MS measurements of investigated zircon grains. U and Pb content and Th/U ratio were calculated relative to the GJ-1 zircon standard and are accurate to approximately 10%. Gerdes, A., and A. Zeh (2006), Combined U-Pb and Hf isotope LA-(MC-)ICP-MS analysis of detrital zircons: Comparison with SHRIMP and new constraints for the provenance and age of an Armorican metasediment in Central Germany, Earth and Planetary Science Letters, 249, 47–61. Linnemann, U., K. Ouzegane A. Drareni, M. Hofmann, S. Becker, A. Gärtner, and A. Sagawe (2011), Sands of West Gondwana: An archive of secular magmatism and plate interactions – A case study from the Cambro―Ordovician section of the Tassili Ouan Ahaggar (Algerian Sahara) using U-Pb LA-ICPMS detrital zircon ages, Lithos 123, 188–203. Stacey, J.S. and J.D. Kramers (1975), Approximation of terrestrial lead isotope evolution by a two-stage model, Earth Planet. Science Letters 26, 207–221. Table S1. Settings for the instruments used in the Geochronological Laboratory (GeoPlasmaLab Dresden) of the Senckenberg Naturhistorische Sammlungen Dresden (Excimer Laser, New Wave, UP 193) and (ICP-MS, Thermo-Fisher, Element 2 XR). ICP-MS Finnigan Element 2 XR Forward Power Gas flow rate 1390 W 15.0 l min-1 (plasma) 1.07 l min-1 (aux) E-scan 202, 204, 206, 207, 208, 232, 235, 238 300 18 ns < 1% 4 ms ≤ 1 ms/amu 1500 15 s 30 s 1.4 s (=25 scans) Scan mode Scanned masses Mass resolution Dead time Oxide UO+/U+ Dwell time Settling time Number of scans Background Ablation time Integration time Laser system Nominal spot diameter Carrier gas Laser settings Drill speed (DS) / Raster scan speed (RSS) Cell volume Sensitivity UP193 New Wave 193 nm, excimer 25-35 µm (unknowns) 35 µm (standard) 0.25 l min-1 He 1.1 l min-1 Ar 10 Hz, 55% LP ~ 0.5 µm/s (DS) c. 3 cm3 6 x 10 counts/pg U 6