Date: Sep. 11, 2009 Doc: Architect/ Engineer Specifications (Draft) Model: SIP-3020/5, SIP-4010/5, SIP-404/5 Description: Outdoor PIR Detector for video surveillance The outdoor detector[s] shall operate on a verified Intrusion principle using Passive Infrared (PIR) to trigger video equipment. 1) Output and Enclosure [Each] [The] detector shall provide detection, signal processing, alarm relay, and operating power circuitry in the same enclosure; and shall provide an alarm relay actuation upon the detection of an intruder moving into or through its protection pattern. [Each] [The] detector has independent two Alarm Outputs for main area and creep zone. The Alarm Output of main area shall be capable of handling 28VDC, 0.2A max, Form C. The Alarm Output of creep zone shall be capable of handling 28VDC, 0.2A max, Form C. Anti-Masking signal from trouble output. N.C., 28 VDC 0.2 A max. The detector has built in active infrared beam from a transmitter to receiver. Masking the PIR’s detection area may cause a missed alarm. REDWALL-V series can recognize any masking material in front of the detector and generate a trouble output to notify any attempt at masking. Anti-Rotation signal from tamper output. The detector has a built in 3-axis accelerometer. When the detector detects a change of angle vertically or horizontally from the original installed position or any attempt to vandalize the unit, the 3-axis accelerometer can generate a tamper alarm to notify the status. Also, when the unit receives a shock, cover is removed or the main unit is removed from its base, a signal will be generated from the tamper output. N.C., 28 VDC 0.1 A max. The enclosure is made of molded reinforced polycarbonate. It shall be ready for wall installation. The total weight shall be 48 oz. (1.4kg). 2) LED Operation The detector[s] shall incorporate two Red LEDs to indicate the operating conditions. Two Red LEDs illuminated shall indicate an alarm condition for main area and creep zone independently. Red LED not illuminated shall indicate a non-alarm condition. A blinking Red LED shall indicate power ON or Warm-Up period. 3) Power Requirement The detector[s] shall be capable of operating from an AC or DC power source rated within the range of 11 to 16 volts DC ± 10% or 22 to 26 volts AC ± 10%, and shall draw a maximum of 40 milli-amps (mA) at 12 volts DC or 75 milli-amps (mA) at 24 volts AC. When the SIP-HU is used, the power for SIP series should be 22 to 26 volts AC ± 10%, and shall draw a maximum of 415 milli-amps (mA) at 24 volts AC. 4) Alarm Operation A condition of alarm shall occur when the PIR alarm conditions are met. Sensitivity adjustment shall include settings of L(Low), M(Medium), H(High) or SH(Super High) for near area and far areas independently. The Alarm Period shall be 2.0 ± 1 seconds. The pulse count shall be adjusted automatically by setting it to 1 or 2 pulses. [Each] [The] detector shall signal the condition of alarm using N.C. and N.O independent relays for main area and creep zone independently. [Each] [The] detector shall also contain a tamper switch that shall open when the cover is removed or the main unit is removed from the base. Also, the tamper switch shall open when the main unit is rotated or receives a shock. 5) Sensor Stability No alarm shall occur at 10V/m from 100MHz to 2GHz. The patented multi-focus lens creates zones with high vertical density, providing maximum detection sensibility that shall remain stable even in high temperature conditions. [Each] [The] detector shall be rated to tolerate a temperature change of 1.8°F/min within the range of [minus 13°Fahrenheit to plus 140° Fahrenheit] [minus 25° Celsius to plus 60° Celsius]. [Each] [The] detector shall also tolerate a humidity rate of 95% max. No false alarm shall occur within these operating conditions. [Each] [The] detector shall also feature Visible Light Protection capability. The patented Double Conductive Shielding of the Pyro Electric Element shall provide a high protection level that exceeds H4 halogen (car headlight) within 15ft (4.5m) To ensure proper circuit operation, the detector[s] shall incorporate a PIR self-test within defaults. When the device is turned on, the warm-up period shall be approx. 60 seconds, during which a Red LED blinks. Intelligent PIR Detection System; Detection of ambient temperature and illuminance for automatic sensitivity management. The detector utilizes thermo and luminance sensors which monitors the environmental information for ideal sensitivity control. The detector can reduce false alarms with optimum sensitivity even if the surrounding conditions have changed. Advanced detection algorithm. Three dual pyro-elements with patented Double Conductive Shielding for main area. (Two dual pyro-elements for Near Area and one dual element for Far Area.) Built-in creep zone detector; The detector equips additional PIR detector on the bottom to cover the area just below the unit. (Two dual pyro-elements) Anti-vandalism functions; Anti-rotation function with 3-axis accelerometer Anti-masking function with photo-beam Reinforced polycarbonate housing Max. 4m (13ft.) installation height Independent sensitivity selector; In order to adjust the sensitivity properly, Creep Zone, Near Area and Far Areas can be adjusted independently. Detection logic selector; The Near Area sensor has two dual pyro-elements, and the unit covers two types of plane area alternately. The Detection Logic mode can be selected to “Or” or “And”. When using the “Or” mode, a sensor signal is output when an object is detected in either of the two detection areas. When in the “And” mode, the sensor signal is output only when an object is detected within the two detection areas. 6) Optics and Detection Patterns Mirror optics shall focus received infrared energy onto the sensor. [Each] [The] detector shall contain a durable high grade UV resistant polyethylene window. The SIP-3020/5 sensor shall construct a Wide Angle detection field, 100 x 65 ft. (30 x 20m) and the creep zone, 10 x 16ft. (3 x 5m) installed at 7.6ft. (2.3m) height, 20 x 30ft. (6 x 9m) installed at 13ft. (4m) height. The SIP-4010/5 sensor shall construct a narrow detection field, 130 x 33ft. (40 x 10m) and the creep zone, 10 x 16ft. (3 x 5m) installed at 7.6ft. (2.3m) height, 20 x 30ft. (6 x 9m) installed at 13ft. (4m) height. The SIP-404/5 sensor shall construct a narrow detection field, 130 x 13ft. (40 x 4m) and the creep zone, 10 x 16ft. (3 x 5m) installed at 7.6ft. (2.3m) height, 20 x 30ft. (6 x 9m) installed at 13ft. (4m) height. By utilizing the optional area view finder, AVF-1, the detection area can be visualized. It can be helpful for an installer to see objects in the detection pattern. Detection range selector; In order to properly set up detection, unwanted areas should be masked or eliminated. “Off” or “On” mode can be selected. When in “Off” mode, the unit cancels the far area detection, and the detection distance is limited to approximately 65ft (20m). Masking plate and stickers By using area masking plates and stickers, unwanted detection segment can be eliminated. 7) Operation temperature -13 to +140 F degree, -40 to +140 F degree with optional heating unit (-25 to +60 C degree, -40 to +60 C degree with optional heating unit) MODEL The outdoor PIR detector shall be model SIP-3020/5, model SIP-4010/5 or SIP-404/5. Optional walk tester - OPM-WT, area view finder - AVF-1, Sun/snow shield - SIP-MINIHOOD and Heating unit – SIP-HU (When the SIP-HU is used, the power for SIP series should be 22 to 26 volts AC) are available. End.