INTERNATIONAL MANURE AND REFUSE SAMPLE EXCHANGE

advertisement
INTERNATIONAL MANURE AND REFUSE SAMPLE
EXCHANGE PROGRAMME
METHOD INDICATING CODE (MIC)
HOW TO USE THE MIC FORMS:
*
the MIC should be reported only once;
*
use the MIC registration form on page 4 for reporting you MIC;
*
always fill in your code name and code number;
*
always fill in the starting date of the MIC codes;
*
fill in the element and corresponding code number (see form for results);
*
fill in the code for the used digestion and extraction technique (table 1);
*
fill in the used method of detection (table 2);
*
sent this form always by surface mail even when you use fax or E-mail because
sometimes it is problematic to get clear readible documents.
Example
You indicate behind the element Cd under the digestion and extraction technique the code A,
and under the detection technique the code BAE. This example means that for the determination of Cd in manure and refuse material in your laboratory a dry ashing method and uptake
of the ash in HCl is used ; for the detection of Cd AAS-ETA with Zeeman background
correction is used.
document code
version
: IF03.12
: 04 (November 2003)
page 1 of 4
INTERNATIONAL MANURE AND REFUSE SAMPLE
EXCHANGE PROGRAMME
METHOD INDICATING CODE (MIC)
TABLES
Table 1
A
B
C
D
E
F
G
H
I
K
L
M
N
O
P
Q
R
S
T
Z
Digestion/extraction and other procedures
Dry ashing and uptake af the ash in HCl
Dry ashing and uptake of the ash in HNO3
Digestion with a mix. of conc. HCl (ISO-11466) using boiling under reflux
as C using a microwave system
Digestion with (conc) HNO3 under pressure
As E using a microwave system
Digestion with HNO3/HF/HCLO4 under pressure
melt with LiBO2
digestion with HNO3 and H2O2
dry ashing and digestion of the ash with HNO3 under pressure
as K using a microwave system
Digestion with H2SO4/H2O2 LiSO4/Se as a catalyst
Extraction with 2 M HNO3 1:10 at 100oC
Digestion with KMnO4 at 70 oC
Extraction with KCl 2 M 1:20
Digestion with conc HNO3
(for the elements Mo and AOX) method according to DIN 38414S18
Digestion with conc H2SO4
Using aqua regia (EN 13346 for sludges) and (EN 13657 for waste)
Others (give a short description)
document code
version
: IF03.12
: 04 (November 2003)
page 2 of 4
INTERNATIONAL MANURE AND REFUSE SAMPLE
EXCHANGE PROGRAMME
METHOD INDICATING CODE (MIC)
TABLES
Table 2
Methods of detection
AA
AAA
AAB
AAC
AAD
AAE
AAF
AAG
AAH
AB
ABA
ABB
ABC
ABD
ABE
ABF
ABG
ABH
BA
BAA
BAB
BAC
BAD
BAE
BAF
BAG
BAH
CA
CB
CC
D
E
F
G
H
IA
IB
JA
JB
JC
KA
KB
L
M
O
P
Q
Z
AAS-Flame without preconcentration
without background correction using air-acetylene
without background correction using N2O-acetylene
with deuterium background correction using air-acetylene
with deuterium background correction using N2O-acetylene
with Zeeman background correction using air-acetylene
with Zeeman background correction using N2O-acetylene
with pulsed hollow cathode lamp background correction using air-acetylene
with pulsed hollow cathode lamp background correction using N2O-acetylene
AAS-Flame with preconcentration
without background correction using air-acetylene
without background correction using N2O-acetylene
with deuterium background correction using air-acetylene
with deuterium background correction using N2O-acetylene
with Zeeman background correction using air-acetylene
with Zeeman background correction using N2O-acetylene
with pulsed hollow cathode lamp background correction using air-acetylene
with pulsed hollow cathode lamp background correction using N2O-acetylene
AAS-ETA without preconcentration
without background correction without chemical modifier
without background correction with chemical modifier*
with deuterium background correction without chemical modifier
with deuterium background correction with chemical modifier*
with Zeeman background correction without chemical modifier
with Zeeman background correction with chemical modifier*
with pulsed hollow cathode lamp without chemical modifier
with pulsed hollow cathode lamp with chemical modifier*
Flame emission
ICP-AES (different wavelengths are possible; indicate the used wavelength)
other excitation source (dif. wavelengths possible;indicate used wavelength)
ICP-MS
Spectrophotometry
Hydride technique (simular techniques using analyte volatilization;specify)
Cold vapour technique
Ion selective electrode
Direct voltammetry
Stripping voltammetry
Gas chromatography
Liquid chromatography
Ion chromatography
X-ray fluorescence with material melted
X-ray fluorescence with material pressed
Neutron activation analysis
Near infrared
Titrimetric/Coulometric
Gravimetric
Turbidimetric or Nephelometric
Others (give a short description)
document code
version
: IF03.12
: 04 (November 2003)
page 3 of 4
INTERNATIONAL MANURE AND REFUSE SAMPLE
EXCHANGE PROGRAMME
METHOD INDICATING CODE (MIC)
Codename: …………….
Codenumber: …………….
MIC codes starting date: …………….
MIC MODIFICATION FORM
For the code numbers see form for results
Element
document code
version
Code number
: IF03.12
: 04 (November 2003)
Method of digestion/extraction
Method of detection
page 4 of 4
Download