6112/ل/1 عطاء رقم كلية العلوم/توريد وتركيب وتشغيل أجهزة خمربية :املواصفات اخلاصة Item 1 quantity Description Real Time PCR System with Notebook, Open System Features: 5 channels multiplexing for discrimination of up to five targets in a single reaction well* Strong flexibility thanks to the 96-well format suited for standard PCR microplates, test tubes and strips, Optimal signal/noise ratio, Light emitting diodes (LED) detection using multiple exposure method Technical Characteristics : Thermal block format 96 test tubes of 0.2ml (12x8) Range of thermal block temperature control 0C…100C Resolution of temperature setting 0.1C Absolute accuracy of temperature maintenance ±0.2C Uniformity of thermal block temperature ±0.15C Hot cover Temperature 105C ±1C Excitation source Light –emitting diode (LED) Detector CCD ( Charge coupled device ) Number of the fluorescence measurement 5 Excitation/detection wave length 470/252, 532/570, 585/633, 633/670, 690/750 Threshold sensitivity of each of the channels for solution of standard fluorophores 1 2 1 Analytical Balances Capacity g : 210 Readability mg : 0,1 ( 0.0001g) Linearity mg : ± 0,2 Repeatability mg : ± 0,05 functions and characteristics 3 LCD display with small decimal digits Membrane keyboard, water proof and solvent resistant, easy to use with TARE, ON/OFF, PRINT and MODE keys Indication of the reached stable weight Bar-graph indicator of dosage and remaining capacity of the balance Parameters configurable by menu: reading in g (grams), lb (pound), oz (ounce), ct (carats), pcs (pieces), % (percentage) Full scale automatic calibration with external mass Weighing underneath the balance Selectable response time “fast/slow” (see table) 1 Autoclaves Specification : Control Chamber Volume (L) Sterilization Temp. (℃) Temperature 1) Melting Temp. (℃/℉) Safety Timer Microprocessor PID Control 50 / 1.8 110 to 123 60 to 100 Over Temperature Protector / Pressure Safety Valve / Over Current Pr tector Warning Alert (Over Temp. / Low Temp. / Low Heat / Sterilization Fail / Low Water Level) 0 to 999 min Standard modes (Decontamination, Solids Sterilization, Liquids Sterilization, Melting) Program modes (Sterilization 1, Sterilization 2, Liquid Sterilization, Melting) Programs 4 pH/Temperature Bench Meter This pH/temperature bench meter provides intuitive software and a well-organized LCD display, making operation quick and simple. It also offers a functional design and reliable calibration results, which are tracked on the display, ensuring precise measurements time after time. This meter measures the pH and the temperature of a sample and includes a builtin 2-in-1 plastic electrode, temperature sensor, and a pH buffer Specification Calibration 2 Points at least 1 Predefined Buffer Group (4.01, 7.00, 10.01) Error Limits ±0.01 pH ±0.5° C Power Supply Range 110 to 240 V/50 Hz, DC 12 V 0.00 to 14.00 pH 1 Resolution 5 0 to 100° C 0.01 pH 0.1° C REFRIGERATED BENCH TOP CENTRIFUGE Maximum speed : 4.100 rpm Swing-out / 14.000 rpm Angle Maximum RCF : 3.045 xg Swing-out / 18.405 xg Angle Maximum capacity : 4 x 200 ml Swing-out / 24 x 1,5/2 ml Angle Temperature range : -9°C / +40°C (+4°C at max. speed ) Programmable microprocessor control system Digital displays for prog. no, speed, rcf, time, temperature, acceleration and braking rates 10 program memories Timer : 1 - 99 minutes and hold position 10 acceleration / 10 braking rates Safety features : Imbalance detection, lid interlock, chamber guard ring, motor over temperature , rotor over speed, diagnostic system 1 ACCESSORIES Puller for rotor removal Swing-out rotor 4 x 200 ml, 4.100 rpm, 3.045 xg Set of 4 buckets Set of 4 buckets with sealing cap Set of 4 200 ml PP bottles with cap Set of 4 inserts 1 x 100 ml Set of 4 inserts 1 x 50 ml conical Set of 4 inserts 7 x 15 ml Set of 4 inserts 3 x 15 ml conical Set of 4 inserts 7 x 5/7 ml 1 1 1 1 1 1 Angle Rotor 30 x 15 ml 4.100 rpm 3.007 xg Adaptor for 1,5/2 ml (Ø11mm) tubes , (Should be ordered according to the capacity of the rotor) Adaptor for 13 x 100 mm vacuumed / non-vacuumed tubes (Should be ordered according to the capacity of the rotor) Adaptor for 13 x 75 mm vacuumed / non-vacuumed tubes (Should be ordered according to the capacity of the rotor) 6 7 1 1 1 1 1 1 1 Angle rotor 24 x 1,5/2 ml 14.000 rpm, 18.407 x g Adaptor 500 / 800 μl Adaptor 200 μl PCR Adaptor 250 / 400 / 700 μl 1 1 1 1 Angle rotor 6x50 ml 9.000 rpm, 9.418 xg Set of 6 adaptors 1x15 ml conical Set of 6 rubber base adaptors for 50 ml conical tubes 1 Microtitre rotor 4.100 rpm, 2.349 xg 1 Fluorometer Dual-channel fluorometer 1 Equipped with two fluorescence channels for nucleic acid and protein quantitation: Blue fluorescence channel: Excitation 495nm shortpass (wavelengths up to 495nm), emission 510–580nm Red fluorescence channel: Excitation 640nm shortpass (wavelengths up to 640nm), emission 660–720nm Imager System Imager software with USB connection to PC Built-in, 21 x 26cm pullout UV-transilluminator With Imager Analysis software Viewing window for gel observation with standard 560 nm amber filter. 1 Specification : UV light 312(302) nm Camera Minimum 5.0 MP Image Storage PC Connection USB to PC Display LED Viewing Window For gel observation Light Optional Accessory White light (standard) White light table (power built-in) 470 nm Blue light (power built-in) Safety USB port CE, FCC for PC connection Accessories Optical EtBr filter (620 nm) for SmartView Pro Imager Optical SYBR Green filter (520 nm) for SmartView Pro 8 Hotplate Mignatic Stirrers Stirrers Bar set 1 1 9 Incubated Shakers Digital incubating benchtop shakers Operating Features General Control touch screen LCD controller with easy icons and logical menus. -volatile set point memory after power interruption. -in RS-232 port and USB port for external control and data collection. Shaking Control Speed range: 10 to 500 rpm. Timer range: 1 min. to 999 min. -free operation. - Automatic shaking speed adjustment in case of excessive workload such as unbalanced load placement, unusual vibrations caused from unstable floor or external shock. -current, stalled platform check Specification: Range (℃ ) Temperature Fluctuation 1) at 37℃ in flask (±℃) Variation 1) at 37℃ in flask (±℃) Amb. +5 to 80 0.1 / 0.18 0.5 / 0.90 1 Shaking System Motion Type Amplitude Size (mm / inch, dia.) Speed Range (RPM) Accuracy Timer Max. Load (kg ) 11 TOPLOADING BALANCES Capacity g : 210 Readability g : 0,001 Orbital 19.1 / 0.75 10 to 500 ±1% of set speed (>100rpm) / ±1 (<100rpm) 1 min. to 999 min. 10 / 22.0 at 500 rpm 18 / 39.7 at 400 rpm 1 Linearity g : ± 0.002 Repeatability mg : ± 0.001 Response time : ~ 3 sec. Pan mm: Ø 110 Calibration mass : External 1 11 WATER DISTILLER - Capacity: 3.5 lt/hr. at least. - Stainless steel boiler and condenser - Stainless steel heater - Distillation led - Manometer for water pressure - Warning led for shortage of water or overheating 1