CURRICULUM VITAE RABIUL KARUNAI .S Contact no: +91-9715939364 Welding Inspector E-Mail : rabiulmech625@gmail.com OBJECTIVE: Seeking a challenging career & adequate experience in quality assurance, quality control, quality procedure, system, standards and code practice. Education Qualification: BACHELOR OF DEGREE IN MECHANICAL ENGINEERING - FIRST CLASS ANNA UNIVERSITY, Tamilnadu, India. Additional Certifications: Certified CSWIP 3.1 – Certified Welding Inspector from TWI, London Level II in Non Destructive Testing (NDT) as per ASNT/SNT-TC-1A Radiographic Testing (RT) Ultrasonic Testing (UT) Magnetic Particle Testing (MPT) Liquid Penetrant Testing (LPI) Specialization: Have specialized in Quality Assurance and Quality Control activities as given below: Welding and NDT inspections of Pressure parts to ASME requirements Performing, Supervising and Interpretation of VT, PT, MT, RT, UT Receipt inspection of Materials and its documentation verification Conduct stage wise inspections for the compliance of QCP for pressure parts fabrication of boiler. Thickness survey, Dimensional checks and Weld inspection by NDT for water wall and spiral panels. Inspection of Preheating and PWHT. Review of SR charts and harness checks. Periodic audits of Consumable storage at site and Main Stores. Preparation and approval of Daily QC reports. Co-ordination with TPI and Client Inspectors. Safety checks of Front End welding and Spacer crews Page 1 of 4 Experience Details: Having experience as a QC Inspector in the field of Fabricating Boiler pressure parts, Tubular products. Company: INTERTEK MOODY INDIA PVT LTD Project Details Project I : Title : VINDHYACHAL SUPER THERMAL POWER PROJECT (2x500MW), VALLUR TPP UNIT 1 Water wall panels (straight panel& bend panel) Main Contractor Client Position Date : : : : BHEL NTPC QC Inspector May 2009 - Dec 2010. Responsibilities : Overall responsible for all quality related matters at the site. Co-ordination with TPI and Client Inspectors Review and commenting of MS & ITP relates to Welding and NDT activities Preparation and approval of Daily QC reports Conducting UT, MT & PT for welds under repair or in question Routine checks of Welding Consumable storage conditions Day-to-day Safety checks at the site and issuance of Near Miss report Project II : Title Main Contractor Client Position Date : : : : : RIHAND SUPER THERMAL POWER PROJECT (2x500MW), MAUDA II Water wall panels BHEL NTPC, NLC QC Inspector Jan 2011 - Oct 2011 Project III Title Main Contractor Client Position Date : : : : : : BARH I, BARH II (660 MW) SPIRAL PANEL (BENSON BOILER) BHEL NTPC QC Inspector Nov 2011- Till Dated Page 2 of 4 Responsibilities: Developing and review of Welding procedures, Inspection Procedures and ITPs Responsible for inspection of Water Wall Panel of BHEL TRICHY UNDER THE STANDARDS SQP: PP 06: REV07, QCP: 001 REV06, SIP: PP 02. Conduct VT of welds during modification and maintenance works. Preparation of QC reports and test dossiers. Welding Inspection of Mainline / Tie-In & Repair Weld (Automatic + Manual) Welding Consumable Storage Inspection and Certificates verification Radiographic film interpretation and evolution in compliance with Relevant codes. Co- Ordination with NDT /PWHT Crew All quality inspection activities accordance with IBR & ASME / ANSI, and Client project specification. Conduct and witness of procedures and welder qualifications of SMAW and GMAW. Film interpretation of Radiographs throughout the project, for above mentioned all Projects. Submission of Radiographs and NDE reports to client inspectors, as an Internal UT Cross checker, assigning job to NDT crew. Material Identification by using Spectro Machine. Well conversant with Material Specification for Tubular Products as per Vessel Code ASME Section II Part A. Pressure Well Conversant with Various Arc Welding Process like SAW, GMAW, And GTAW process. IBR certificates for Pressure Parts. Coordinating with customer (NTPC) for offering the Product As per Contract Quality Plan. Materials classification / color coding identification, Review and approve relevant quality control documents. Inspect the hydro test of panels(straight & bend) as per IBR Visual Inspection & Orientation Checking Computer skills: ERP : SAP 4.7end user. DESIGN SOFTWARE’S : Auto CAD 2010, PRO-E WILD FIRE 2.0 APPLICATION SOFTWARE : MS Word, MS Excel, MS Power point Page 3 of 4 Passport Details: Passport No. : J2279144 Date of Issue : 30/03/2011 Date of Expiry : 29/03/2021 Personal Details: Name : RABIUL KARUNAI.S Date of Birth : 07.06.1989 Father's Name : SHEIK ABDUL KADHER.M Gender : Male Nationality : Indian Marital Status : SINGLE Languages Known : ENGLISH, TAMIL Permanent Address : 7/38, Church street, Thuvakudimalai, Trichy - 620022. Driving License Details: Country : India Vehicle Description : Light duty driving License No. : TN45Y 20100002383 Date of Issue : 12/07/2010 Date of Expiry : 11/07/2030 Declaration: I hereby declare that, all the above furnished details are true to the best of my knowledge and brief. Date : Place : (RABIUL KARUNAI .S) Page 4 of 4