Item DL 2109T DL 1013M2 Spec's This system must be composed of a set of modules for the study of electrical measurements With this system, it must be possible for the student to test and study the operational characteristics of electrical measurements. In particular, it must be possible to perform the following experiments: •DC current measurement •AC current measurement •DC voltage measurement •AC voltage measurement •Ohm's law •Bridge circuit •Capacitive reactance •Power in DC circuit •Power in single-phase circuit •PF measurement in single-phase circuit •Inductive reactance •One-wattmeter method •Two-wattmeter method •PF measurement in three-phase circuit •Four-reading method •Six-pulse bridge circuit In order to perform these experiments the following modules shall be necessary. POWER SUPPLY – didactic equipment This item must be suitable for supplying fixed and variable alternating current and fixed and variable rectified direct current, in order to carry out easily all the tests on electrical machines and in general in an electric measurement laboratory. It must include a start pushbutton with remote control switch, stop pushbutton, key-unlocked emergency mushroom head pushbutton and differential magneto-thermal protection on the mains sockets. Technical features Output voltages: Variable AC: 3 x 0 - 430 V, 5 A 3 x 0 - 240 V, 8 A Fixed AC: 3 x 380 V + N, 16 A 3 x 220 V, 8 A Q.ty Standard fixed AC: 220 V, 10 A Variable DC: 0 - 240 V, 10 A 0 - 225 V, 1 A The turret must be equipped with the following parts: Key general switch Magnetothermal differential three-switch Magnetothermal differential single-switch Three-phase variator protection switch Three-phase autotransformer protection switch Commutator to supply fixed or variable Magnetothermal main switch Variable three-phase output switch DC output switch Three-phase output switch Variable DC excitation output switch Emergency pushbutton Running pushbutton Stop pushbutton Supply warning light Three-phase warning light Voltage selection warning lights Variable DC excitation warning light Max speed connector Knob for D.C. and A.C. output Knob for D.C. excitation output Magnetic-thermal protection for D.C. output Connector for overspeed protection of motors Power supply: 3x380 V + N, 50/60 Hz Dimensions (W x H) : 998 x 293 mm. It must be supplied with manual in English language. DL 1017R RESISTIVE LOAD – didactic equipment It must consist in a single or three-phase resistive step-variable load. Housed in a metallic box. MECHANICAL FEATURES The load shall be composed of a rugged metal structure and of a front metal panel. On the front panel all the controls, the protection, the output terminals and a clear synoptic diagram, shall be collected. ELECTRIC FEATURES The load shall be composed of resistances, with possibility of star, delta and parallel connection, controlled by three switches. This item must be provided also with fuses protection. As a function of the switch positions, there shall be the following phase values: Position Resistance Max power per phase 1 1050 Ohm 46 W 2 750 Ohm 65 W 3 435 Ohm 110 W 4 300 Ohm 160 W 5 213 Ohm 230 W 6 150 Ohm 330 W 7 123 Ohm 400 W Maximum power in single or three phase connection must be 1200 W. Rated voltage in star connection must be 380 V, in D connection must be 220V, in single-phase must be 220V. It must be supplied with manual in English language. Dimensions (W x H): 436 x 174 mm DL 1017L INDUCTIVE LOAD – didactic equipment It must consist of a single or three-phase inductive step-variable load. Housed in a metallic box. MECHANICAL FEATURES The load shall be composed of a rugged metal structure and of a front panel. On the front panel all the controls, the protections, the output terminals and a clear synoptic diagram, shall be collected. ELECTRICAL FEATURES The load shall be composed of inductances, with possibility of star, delta and parallel connection, controlled by three switches. This item must be provided also with fuses protection. As a function of the switch position there shall be the following phase values. Position Inductance Max. Power per phase 1 4.46 H 34 VAr 2 3.19 H 48 VAr 3 1.84 H 83 VAr 4 1.27 H 121 VAr 5 0.90 H 171 VAr 6 0.64 H 242 VAr 7 0.52 H 297 VAr Max reactive power 890 VAr in three-phase or single-phase connection. Rated voltage in star connection must be 380V, in D connection must be 220V, in single-phase must be 220V. It must be supplied with manual in English language. Dimensions (W x H): 436 x 174 mm DL 1017C CAPACITIVE LOAD – didactic equipment It must consist of a single or three-phase capacitive step-variable load. Housed in a metallic box. MECHANICAL FEATURES The load shall be composed of a rugged metal structure and on the front panel all the controls, the protections, the output terminals and a clear synoptic diagram shall be collected. This item must be provided also with fuses protection. ELECTRICAL FEATURES The load shall be composed of capacitors, with possibility of star, delta and parallel connection, controlled by three switches. As a function of the switch position, there shall be the following phase values (at 50Hz): Position Capacitance Max power per phase 1 2 μF 30 VAR 2 3 μF 45 VAR 3 5 μF 76 VAR 4 8 μF 121 VAR 5 10 μF 152 VAR 6 13 μF 197 VAR 7 18 μF 275 VAR Max reactive power in single-phase or three-phase connection 825 VAr. Rated voltage in star connection must be 380V, in D connection must be 220V, in single-phase must be 220V. It must be supplied with manual in English language. Dimensions (W x H): 436 x 174 mm DL 2101T13 TRANSFORMER - didactic equipment This module must consist of a single-phase transformer for low voltage modules with the following characteristics: Primary: 127-220 V Secondary: 2x12 V Rated power: 100 VA This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Dimensions (W x H): 100 x 297 mm It must be supplied with manual in English language. DL 2109T02 DL 2109T03 SEQUENCYSCOPE UNIT - didactic equipment This module must consist in a indicator of the phases cycle through signalling lamps with rated voltage: 3 x 380 V/220 V. This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Dimensions (W x H x D): 100 x 297 x 100 mm It must be supplied with manual in English language. BRIDGE RECTIFIER - didactic equipment This module must have insulated type front panel with the electrical scheme; it must include also safety terminals. Three-phase Graetz bridge. Power supply: 220 Vac Rectified output: 300 V - 24 A Dimensions (W x H x D): 100 x 297 x 100 mm It must be supplied with manual in English language. DL 2109T04R POTENTIOMETER - didactic equipment This module shall consist of a excitation rheostat that shall be for shunt or compound excitation of dc machines and for alternators. This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Rheostat, 680 Ω, 0.47 A, 150W Dimensions (W x H x D): 200 x 297 x 100 mm It must be supplied with manual in English language. DL 2109T06 DOUBLE CHANGE-OVER UNIT - didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Two pole two-way commutator, 380 V, 16 A Dimensions (W x H x D): 100 x 297 x 100 mm It must be supplied with manual in English language. DL 2109T10 MICROAMMETER - didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Moving coil, zero centred, with sensitivity reducer. Range: 50/0/50 µA Reducer: 1/10 Scale amplitude: 240° Dimensions (W x H x D): 300 x 297 x 100 mm It must be supplied with manual in English language. DL 2109T11 MILLIAMMETER – didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Moving coil with rectifier. Range: 250/500 mA, DC and AC Scale amplitude: 240° Dimensions (W x H x D): 300 x 297 x 100 mm It must be supplied with manual in English language. DL 2109T12 AMMETER – didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Moving coil with rectifier. Range: 2.5/5 A, DC and AC Scale amplitude: 240° Dimensions (W x H x D): 300 x 297 x 100 mm It must be supplied with manual in English language. DL 2109T14 VOLTMETER – didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Moving coil with rectifier. Range: 25/50 V, DC and AC Scale amplitude: 240° Dimensions (W x H x D): 300 x 297 x 100 mm It must be supplied with manual in English language. DL 2109T15 VOLTMETER – didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Moving coil with rectifier. Range: 250/500 V, DC and AC Scale amplitude: 240° Dimensions (W x H x D): 300 x 297 x 100 mm It must be supplied with manual in English language. DL 2109T17 SINGLE-PHASE WATTMETER – didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Moving coil. Range: 2.5-5 A / 240-480 V Scale amplitude: 240° Power supply: 24 Vac Dimensions (W x H x D): 300 x 297 x 150 mm It must be supplied with manual in English language. DL 2109T18 SINGLE-PHASE PHASEMETER – didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Moving coil meter with transducer for single-phase ac. Range: 1.5-6 A / 80-250 V Scale amplitude: 240° x (0,5 cap - 1 - 0,5 ind) Power supply: 24 Vac Dimensions (W x H x D): 300 x 297 x 180 mm It must be supplied with manual in English language. DL 2109T19 THREE-PHASE PHASEMETER – didactic equipment This module must have insulated front panel with the electrical scheme; it must include also safety terminals. Moving coil meter with transducer for three-wire three-phase systems with balanced load. Range: 1.5-6 A / 100-500 V Scale amplitude: 240° x (0,5 cap - 1 - 0,5 ind) Power supply: 24 Vac Dimensions (W x H x D): 300 x 297 x 180 mm It must be supplied with manual in English language. TL 2109TM CONNECTING LEADS This item must be composed of a set of leads for the connection of the experiment modules. These leads must have different lengths. DL 2100-2M TWO-LEVEL WORK FRAME This item must consist in a metal frame with two levels for fitting the modules of the laboratory. The structure shall be easily mounted on the work bench. Dimensions (W x H x D): 990 x 739 x 40 mm DL 1001-1 WORKBENCH This item must consist in a large sized bilaminated wooden board and square legs with compensation feet. Dimensions: 2 x 0,8 x 0,9 m