główny instytut górnictwa

advertisement
GŁÓWNY INSTYTUT GÓRNICTWA
Plac Gwarków 1, 40-166 Katowice, p.o. box 3672
Tel.: 032 258 16 3 int.9 Fax: 032 259 65 33 e-mail: gig@gig.katowice.pl www.gig.katowice.pl
Bank account: Bank Pekao S.A. O/Katowice nr 65 1240 4227 1111 0000 4841 8133
Regon 000023461 NIP: 6340126016 KRS: 0000090660 GIG is a VAT payer.
We have a certified Integrated Management System (quality, health & safety, environment protection) that conforms to:
PN-EN ISO 9001:2001 PN-N-18001:2004 PN-EN ISO 14001:2005 standards
TEST CERTIFICATE no. 08/2008
Grate boiler of the type - GT - KWR 10 - 300
producer: P.P.U.H. ”GALMET” S. D. R. GALARA spółka jawna
ul. Raciborska 36 48 - 100 Głubczyce
l.n.
details
Fuel : hard coal brick
1. - size
- calorific value
- sulphur content
- ash content
- moisture
2. Boiler efficiency (gross) as per PN -EN 12952 - 15
3. Gas and dust
emitted into the atmosphere in standard conditions
calculated for O2 content = 6 % :
- dust
- sulphur dioxide
- nitrogen dioxide
- carbon monoxide
units
mm
MJ/kg
%
%
%
%
mg/m3
mg/m3
mg/m3
mg/m3
result
5-55
26 - 32
0.35-0.50
<3.0
<3.0
77.8
320 - 530
710 - 840
340 – 370
3100 - 20800
Grate boilers GT - KWR 10 - 300 with a power output of 10 - 300 kW were tested by the Office for Energy
Efficiency and Air Purity, Laboratory of Work Environment Testing and Air Purity with a certificate from the
Polish Centre for Accreditation PCA no. AB 301 and the Office for Solid Fuel Quality Assurance with a
certificate from the Polish Centre for Accreditation PCA no. AB 069.
Grate boilers GT - KWR 10-300 conform to the requirements for gas and dust emissions of the PN EN 303 - 5 : 2002 standard, (Part 5 : Solid fuel boilers with manual or automatic loading with a nominal
power output up to 300 kW - Terminology, requirements, testing and marking.)
stamp and signature of GIG office director
stamp and signature of operation’s director
Katowice. 22.08.2008
Download