MADHIVANAN ARUNACHALAM Senior Engineer- Electrical mathirandy@gmail.com +971503953528 +919945905630 Pudukkottai,INDIA. Abu Dhabi, UAE Summary 6+ years experience in Electrical engineering project management, coordination, inspection, testing,commissioing and quality control. Primary familiarity with power equipments (High,Medium & Low voltage) Benchmarked Industrial switch gears/MCC's and Circuit Breakers; Cutler Hammer, Westinghouse, ABB, SCHINDER, GE, SEL and Cooper protective relays Fuses, transformers, motor protector controls, generators, VFD's, (ALFA) UPS System, HRG grounding, lighting and control systems I have almost 4 years experience in Oil & Gas area - 132kV/11.0kV/3.3kV/410V Electrical Distribution System, Electrical experience of Low and Medium Voltage MCC's, Switchgear, Switchboards and electrical distribution products 2 years Electrical Engineering experience of gulf market (UAE&IRAQ) Regulatory codes: Experienced with national and industry code: ANSI/IEC, NEC, IEEE and API500 Effective communication, interpersonal, problem-solving, planning and coordination skills Always take pride in doing a job, willing to learn new skills, team player, confident and responsible ADDC COMPETENCY Work Experience Lead Engineer- Electrical Basra gas company(KAZ)-(SHELL-TECHNIP), IRAQ-BASRA May 2014 – Nov 2014 Electrical works power distribution systems 11kV/3.3kv/410V Hazardous Area Classifications, Grounding system including HRG Coordination with the clients to ensure that the system Electrical works include the designing of power distribution systems 132/11kV and 11.0kV/3.3kv/410V Hazardous Area Classifications, Grounding system including HRG Coordination with the clients to ensure that the system design is based on the indentured functionality as per requirements and code compliance. Involved in the protection devices coordination work Selection of proper power equipments as per the system requirements. Create Electrical equipment specification, Datasheets and BOM. Participate in the coordination activities and concerns with the technical developments, scheduling and resolving engineering problems. Is based on the indentured functionality as per requirements and code compliance. Involved in the protection devices coordination work Selection of proper power equipments as per the system requirements. Create Electrical equipment specification, Datasheets and BOM. Participate in the coordination activities and concerns with the technical developments, scheduling and resolving engineering problems. Lead Engineering Basra gas company(NORTH RUMAILA)-(CHIYODA-SHELL), BASRA-IRAQ Nov 2014 – Jun 2015 Electrical works power distribution systems 11kV/3.3kv/410V Hazardous Area Classifications, Grounding system including HRG Coordination with the clients to ensure that the system d Electrical works include the designing of power distribution systems 132/11kV and 11.0kV/3.3kv/410V Hazardous Area Classifications, Grounding system including HRG Coordination with the clients to ensure that the system design is based on the indentured functionality as per requirements and code compliance. Involved in the protection devices coordination work Selection of proper power equipments as per the system requirements. Create Electrical equipment specification, Datasheets and BOM. Participate in the coordination activities and concerns with the technical developments, scheduling and resolving engineering problems. Is based on the indentured functionality as per requirements and code compliance. Involved in the protection devices coordination work Selection of proper power equipments as per the system requirements. Create Electrical equipment specification, Datasheets and BOM. Participate in the coordination activities and concerns with the technical developments, scheduling and resolving engineering problems. Electrical Engineering ETA PPT, Abudabi, UAE Jun 2015 Test and start-up of: Overhead power line (MV - 20KV) Power Transformers MV Switchgear Bus Duct Battery Charger Capacitor Bank Lighting Pole MV Cable Termination MV, LV & Earth Cabling Including: Gland installation, Shrouding, Tagging, Connections, Shrink, Wiring Tags, Cable Lugs, Sealants Electrical Panel, Lighting/ socket distribution panel - Lead a team of five electrical engineers in the successful execution of electrical engineering and design for project within budget and on schedule. - Ensure effective communication within the team and between project disciplines, and with client engineers. - Ensure the most current design documents are used to complete the work and that all design changes are approved prior to implementation. - Monitor work activities and ensures the quality of work performed. - Ensure that electrical deliverables adhere to contract standards and client and corporate quality and safety requirements. - Perform employee reviews and identify training and development opportunities for subordinate personnel. Electrical Engineer INEL POWER SYSYTEM, BANGALORE-INDIA May 2011 – Apr 2014 Duties and Responsibilities: Execution and preventive maintenance of electrical systems, such as HV / LV power distribution system, HV / LV bus tie metal clad switch gear rated up to 6,600 V, substation type transformer rated 1500KVA, squired/ induction motor rated up to 2,400 KW, bus tic system, and control/ monitoring system, PLC. Execution and preventive maintenance, inspection related to Vacuum Circuit Breaker rated 6, 600 V, Air Circuit Breaker rated 400V, Control Panel, HV/ LV Cables, HI-Pot testing, Meggering, Protection System, Protective devices. Attend troubleshooting jobs related to generator protection relay, induction motor protection relay, transformer protection relay, UPS, feeder protection relay, VCB. ACB. Handle some modification works pertaining to the electrical power plant generation and other power plant/ desalination auxiliaries. Witness and observe testing/ commissioning of electrical system such as "Bus tie type substation system, Ring main units, VCB,ACB, UPS/ Battery Charger including inverter, transformer OLTC type rated 150 MVA, manual type 80MVA, 42MVA, 20MVA, Induction Motor 3, 600KW, 2,400KW, and 1,700KW, HV/LV Power cables and protection system such as distance relay, thermal O/L relay, Instaneous/ Inverse time O/C relay, DIFFERENTIAL relay, Directional/Back-up impedance relay, locked motor relay, negative sequence relay. Prepare some modification drawing and material take off for electrical equipment control system prior for electrical system up gradation. Log off deficiency noticed during inspection prior for submission to Electrical Maintenance Supervisor/ Engineer. Knowledge on the type of permit and lock out tag, prior for isolation of equipment. Attend some calibration works related for protection system such as generator, motor, transformer, VCB/ ACB relay. Conduct "kick method test", "polarity test" and "second injection test" for current Transformer, instrument transformer and potential/ voltage transformer. Knowledge on how to use the testing and measuring equipment such as PROGRAMMA, ABB TYPE< MERLIN GERIN BREAKER TEST KIT< AVO BM-11 HV MEGGER AND HYPHOTHRONICS TEST KIT FOR WINDING RESISTANCE, measurement. Electrical Engineer SENTHIL ENGINEER, PUDUKKOTTAI-INDIA May 2010 – May 2011 Primary FunctionPerform inspection and adjustment services on electrical equipment. Perform overhaul and maintenance of electrical components, such as auxiliary generators, switchgear, transformer, motors, controls and other electrical or electrically related equipment. Install conduit and pull and terminate or remove wire. Operate and maintain equipment used in power production as related to maintenance and repair. Understand proper use of all tools and equipment used in the electrical repair work. Read and work from sketches, blueprints, manuals and handbooks. Duties and Responsibilities: Installation and repair of lighting and power circuits. Repair of AC & DC motors and solenoid circuits. Maintenance of batteries and associated circuits. Maintenance of low and medium voltage switchgear. Troubleshoot and maintain in all portable plant electrical maintenance equipment. Maintain the necessary equipment for testing and troubleshooting. Conduct and record all maintenance work as set forth in Plant Maintenance Plans and Procedures. Set up the workshop necessary for repair of switchgear. Follow-up all safety procedure in assigned work. Servicing generator exciter control circuits. Testing generator field and stator circuits. Checking and servicing generator breakers and isolation. Performed additional assignment as per supervisor instruction. Testing Of Numrical Relays: ABB Relays REF 615 REF 630 RET 615,RET543 RET 670 RED670 RED615 REX521 REB615 REM543,REM610,REM615 REG543 SPAM140C SPAJ140C REU610,REU615 - Cntl,Over Current & Earth Fault Protection Relay. Bay Control Unit. Transformer Protection Relay. Transformer Differential , REF & , Bus Bar Differential Cable Differential, O/C Protection Cable Differential Protection O/C and E/F Protections BusBar Protection Motor Protection Generator Protection Motor Protection Relay Feeder Protection Relay Voltage Protection Relay SIEMENS Relays 7SJ61,7SJ511 7SJ62,7SJ63 7SJ64 7SJ6026,7SJ6001 - Feeder Protection Relay. Feeder Protection Relay. Feeder Protection Relay Motor Protection Relay Schneider Electric Relays MICOM P111, P141,P143 - Feeder Protection Relay. MICOM P121,P241 - Motor Protection Relay. MICOM P922 - Feeder Protection Relay. MICOM P343,P341 - Generator Protection Relay MICOM P641 - Transformer Protection Relay. Other Relays M3872 MM30 - Beckwidh Electic Generator Protection. - LNT Motor Protection Relay. C&S MIT MTA YTGM CTN ZTO - Transformer Protection Relay. - ERL Transformer Protection Relay - ERL Direction Protection function Relay - EE Impedance Protection Relay - EE Negative phase Seuquence Relay - EE Pole Slipping Relay SOFTWARE USED: Schneider Electric S1 Studio ABB PCM SIEMENS DIGSI PROFPOSINAL QULIFICATION: DEEE (electrical and electronic engineering) DOTE, Chennai-INDIA 2006 – 2008 B.E in Electrical Engineering Anna University of engineering and Technology, Chennai-INDIA 2008 – 2011 DECLARATION: I hereby declare that all the above information’s are true to the best of my knowledge and belief. Date: 03/08/2015 Place: UAE Regards, Madhivanan. A