Embedded Based Multipara Health Care Monitoring System. Pawankumar M. Dhande#1, Harish K.Bhangale*2 Digital Electronics Department, North Maharashtra University Jalgaon , India 1 pawankumar.dhande@raisoni.net harish.bhangale@raisoni.net 2 Abstract— In society, there are increasing number of people whose health requires frequent health check up or examination. People, who passed or suffer from specific diseases, the subsequences of which can occur unexpectedly and result in critical health situation, represent the other group. The solution for this is continuous remote monitoring of certain patient’s functions important for their life with the help needed by providing it. Under remote monitoring the sensing of important data related to person’s health wherever they are can be transmitted into technological centre where they will be evaluated and understood. The applicability of this idea has a great potential. In addition to above group this can also be a question of active or recreation sportsmen, rescuers or various special units where it is necessary to know the basic health parameters of a person this paper considers non-invasive sensors for monitoring of some physiologic parameters, data transport and their processing, archiving and visualization at supervising place using computing equipment (desktop PC, notebook).This methodology was a basis for successive applied research projects that were developed in cooperation with hospitals. calculated by means of computer . The embedded measuring and managing systems represent an important integral part for development of such systems, which are placed directly on their bodies sensing the necessary patient’s data. In application of measuring and control systems in medical systems in medical diagnostics we always face the problems of signal processing. II. HARDWARE There are two systems developed for data measuring: a) The KARD is a system for exercise testing which is used in laboratory. b) The TELEKARD is a telemetric portable exercise testing system that allow to monitor cardio respiratory function in laboratory as well as in field (sport medicine, rehabilitation etc). For data evaluating, the program KONSIL was developed. The program is same for both systems. Keywords - Telekard System, Remote monitoring, Zigbee technology I. INTRODUCTION Physical exercise testing requires the interaction of physiologic mechanism which enable the cardiovascular and respiratory systems to support the increased energy demands of contracting muscles. Both systems are consequently stressed during exercise. Their ability to respond adequately to this stress is a measure of their physical competence (or “health”). An appreciation to the normal response profiles of the gas transport systems that support cell respiration is essential to recognize the abnormal response patterns that characterize the many disease states that affect them. The increased metabolic rate during exercise requires an appropriate increase in O 2 the muscles. Simultaneously, the CO2 produced by muscles must be removed to avoid severe tissue acidosis with its adverse effects on cellular function. This involves the lungs, the pulmonary circulation, the heart, and the peripheral circulation. Heart rate, pulmonary ventilation and breathing frequency are non-invasively measured in patient’s breadth. From these data, many of other standard parameters are Fig.1.The laboratory KARD system for stress test The KARD system is used for laboratory testing which is based on microcontroller. This system is based on AVR Atmel16 microcontroller. If needed ECG can be connected for heart rate measuring. The KARD system was designed to use different types of old gas analyzers (Spirolyt or Infralyt) , but new type of gas analyzers can also be used. The gas-meter with digital serial output was used for ventilation measuring. The heart rate meter SPORTTESTER is used for heart rate measuring and information is transmitted. In Figure 2, the block diagram of the TELEKARD system is drawn. This is a “wireless” device (telemetric system). The equipment is composed of a unit (carried by object) which transmits the measured data to a receiver in area time. The receiver is connected to personal computer (PC) which shows the information on the following devices is used for TELEKARD system:- heart beat. The digital output can be connected to microcontroller directly to measure the Beats per minute (BPM) rate. It works on principle of light modulation by blood flow through finger at each pulse. SENSOR CO2: SENSOR O2: a) %O2 Expiratory- Oxygen sensor, range 0 to 100%. b) %CO2 Expiratory-Infrared carbon dioxide sensor, 0-10%. c) Heart pulse-Heart rate sensor or heart rate meter SPORTMETER is used. d) Flow-turbine flow meter, 26mm, VE range 10-250 1/min. e) Pressure Sensor-differential dual ports integrated silicon pressure sensor on chip signal conditioned, temperature compensated and calibrated MPX5010 is used. f) Temperature sensor-LM 35 can be used as temperature sensor for measurement of temperature. B) MICROCONTROLLER: This is a high performance, low power AVR 8-bit microcontroller. It has non volatile program and data memories. It has 135 instruction and these mostly require single clock for execution so the time required for execution of data is far less than other microcontrollers. C) ZIGBEE MODULE: RF Module Operation: Serial Communications:-The Xbee/Xbee-PRO OEM RF modules interface to host device through logic-level asynchronous serial port. Through its serial port, the module can communicate with any logic and voltage compatible UART, or through a level translator to any serial device (For example through RS-232 or USB interface board)[9]. D) UART DATA FLOW Devices that have UART interface can directly connect to pins of RF-module as shown below Figure 2.TELEKARD System The TELEKARD system is used. The wireless data is used. The signals (a to f) are processed in AVR Atmel16 microcontroller is used and transmitted to a Zigbee RF module (Tarang F4) ,where they are elaborated and presented to the user using PC Figure.4. System Data-Flow in UART-interfaced Environment. E) SERIAL DATA: Data enters the module UART through the DI pin (pin-3) as an asynchronous serial signal. The signal should be idle high when no data is being transmitted. Each data byte consist of a start bit(low), 8-data bits(least significant bit) and stop bit (high). The following figure illustrates the serial bit pattern of data passing through the module. Figure.3.Block Diagram of Telekard System A) HEART RATE SENSOR: Heart beat sensor is designed to give digital output of heart beat when a finger is placed on it. When the heart beat detector is working, the beat LED flashes in unison with each Figure 5.UART data packets as transmitted through RF-module The module UART performs tasks, such as timing and parity checking, that are needed for data communication. Serial communication depends on two UART’s to be configured with compatible settings (baud rates, parity, start bit, stop bit, data bits). III. LIST OF MEASURED AND CALCULATED DATA: During the exercise testing the KARD or TELEKARD acquires the following main signals: Heart frequency, Flow, %O2 Expiratory, %CO2 Expiratory. From these signals, the standard parameters are calculated by the program are the following: Table 1. The Standard Parameters IV. RESULT The system’s non-invasive nature and ease of use makes it ideally suited for clinical situations where monitoring of cardiovascular and ventilatory systems responses under conditions of precisely controlled stress is desirable. Exercise testing with appropriate gas exchange measurements can also serve to grade the adequacy of cardio respiratory function and benefit from the convenience of this simple, inexpensive test. From the measured data, many of other parameters are calculated by means of computer. V. CONCLUSION The embedded system for some physiologic data during physical activities was presented. A properly administered exercise test allows the objective and quantitative assessment of the patient’s performance, reserves and limits that are necessary to make a correct differential diagnosis and institute appropriate therapy. The programs and systems for automatic stress testing have been developed in cooperation with doctors for more than 15 years and now are used in approx.20 hospitals in Czech Republic. VI. REFERENCES 1] Heart Rate Monitoring and Exercise, Journal of Sport Sciences, Vol.16, summer 1998, ISSN 0264-0414 2] M. Stork, ” The System for Spiroergometric Data Measuring and Evaluation, in Proceedings of measurement 2001”,ISBN 80-967402-5-3, EAN 9788096740253,2001, pp.305-308. 3] M. Stork, ”Hardware and software for Spiroergometric Examination”, Medicina sportive Bohemica & Slovaca, ISSN 1210-548, Vol.10, No.2, 2001. 4] Microcontroller Atmel16 data sheet http://www.engineersgarage.com/sites/default/files/Atmega16.pdf 5] R.S.Khandpur,(2003).Handbook of Biomedical Instrumentation, Tata McGraw Hill Education, pg no. 6] Zigbee datasheet available: http://www.melangesystems.com /Pdfs/Tarang.pdf7] Zigbee Alliance Available: http://www.zigbee.org/ 8] Heart rate Sensor http Available:http://pulsesensor.com/category/thelong-blurb/diy-monitors-the-long-blurb/ 9]XgbeePRO-RF-Modulehttp://www.digi.com/products/wireless-wiredembedded-solutions/zigbee-rfmodules/point-multipoint-rfmodules/xbeeseries1-module#overview 10]XBee Pro 802.15.4 OEM RF module datasheet Available: http://www.picaxe.com/docs/xbe001.pdf