048–610–00_PWRCabtmOutdoorCommunicationsCabinetSystem

advertisement
PWR Cab tm Outdoor Communications
Cabinet System
Integrated cabinet with power system and battery back-up for communications and video surveillance
applications.




UL listed NEMA 3R aluminum cabinet.
Integrated 19” equipment rack rails.
Integrated power system options including +12V, +24VDC, -48VDC, 120VAC.
Ethernet port with webserver for cabinet status such as power, intrusion, temperature etc.
Features:











Pad mount or pole mount NEMA 3R Aluminum housing.
Internal 19” rack rails.
Rack mount options for power infrastructure. Front terminal batteries, rectifiers, UPS systems.
Door sense contact closures, temperature sensor, power status sensors for status monitoring.
External AC service disconnect breaker housing option.
PWRcab can be configured for short or long term battery back-up with three voltage options:
+12V,+24V,-48V.
Ethernet port with webserver for power, intrusion, temperature status. Simply plug into the
network for remote monitoring of operation. Requires cable modem, optical switch or WIMAX /
WIFI interface to network.
Fiber optic storage/organizer tray option for fiber storage for OTN applications.
TVSS protector module for AC input power surge suppression.
Battery only version for remote surveillance camera/DVR applications. Includes AC battery
charger interface. Solar panel option available for battery recharge.
Applications include State DOT remote camera surveillance systems, Optical repeaters, remote
transmitters, telemetry systems, small communications nodes/hubs.
General Specifications
Model #
016-519-10
Configuration
 Base Cabinet: 36”
Tall Aluminum NEMA
3R housing. Internal
19” rack rails, Front
and back locking
doors with Best
Locks.
Part #
016-519-10
Description
 Pad mounted base
cabinet with internal
rack rails, front and
back doors, door locks.
See order options
below for full
configurations
including power
Doc# 048–610–00/Nov.01.05









options.
Pad mount. 120VAC
inlet connector. 12V
charger. Battery shelf
with four 12V
batteries in parallel.
RM shelf for DVR
equipment. 12V GMT
fuse panel w/ battery
breaker, LVD. Select
Options: -521: Second
battery shelf (400AH).
-522: 100W solar
panel with charge
controller, -523:
Propane
ThermoElectric
generator system.
Configured for long
standby time, low
power. Select options:
-530: Two battery
shelves, -48VDC
(200AH), 20A N+1
rectifier with ethernet
port, circuit breaker
distribution, 120VAC
input.
-531: Pole mount
bracket. Welded
aluminum, 600 lb.
rated.
-532: AC service
entrance, meter base,
main breaker.
-533: AC UPS 1KVA,
rack mount UPS, 120V
input/output
w/maintenance bypass
switch and power
output receptacles.
-534: -48V 100W solar
panel, charge
controller for
extended remote use.
Configured for higher
power, limited run
Doc# 048–610–00/Nov.01.05








Dept. of
Transportation
remote camera/DVR.
+12VDC. Includes
120VAC inlet with
battery charger, 12V
GMT fuse panel with
battery breaker and
LVD. Battery shelf
with 4x12V front
terminal batteries
(400AH).
time. Select options:
*-540: -48VDC, 60A
N+1 rectifier with
ethernet port, circuit
breaker distribution.
One -48VDC battery
shelf (100AH).
-541: 2KVA UPS, MBS,
internal batteries (15
min. run).
-542: Roof mount Air
Conditioner option.
120V. (Not backedup).
Rack mount fiber optic
storage tray. 2 RU.
Includes dust cover.
AC service entrance,
meter base. 120/240V
200A with 100A
breaker.
Pole mount bracket
kit. Welded aluminum
with hardware. 600 lb.
rated.
Pre-fab plastic vault
base with lid for pad
mounting of cabinet.
24x36"
016-521-10
016-522-10
016-523-10
016-520-10

016-530-10
OTN / EDFA repeater.
Base cabinet above
with integrated
016-530-10
016-531-10
016-532-10
016-533-10
Doc# 048–610–00/Nov.01.05

016-540-10

power, fiber storage,
alarms, and other
options. Select Pole
mount or Pad mount.
016-534-10
Hub cabinet. Base
cabinet above with
integrated power,
fiber storage, alarms,
and other options.
Select Pole mount or
Pad mount.
016-540-10
016-541-10
016-542-10
016-535-10
016-580-10
016-545-10
016-547-10
Accessories:
Common Specifications for All Models:














Dimensions: 22" W x 36" T x 22" D
Weight: 60-550 lbs. depending upon configuration.
NEMA 3R UL listed enclosure.Aluminum with front and back doors with handles and 3 point
latch. Best Lock cylinders.
Unit includes wiring diagram / instruction manual,software, spare fuses etc. depending upon
configuration.
Electrical specifications:
Input: 120VAC for internal charger, rectifier or UPS versions.
+12VDC, +24VDC, -48VDC for battery only or solar powered or TE powered versions.
Units are available with the following power system options:
120VAC input internal 12V or 24V battery charger.
120VAC input internal UPS system with 1KVA or 2KVA 120VAC output.
120VAC input internal -48VC rectifier shelf with rectifier modules.
PV solar panel version with +12V/+24V/-48V 100W or 200W solar panel with charge controller.
Single or dual battery shelves with front access, VRLA 12V batteries connected in 12V,24V or
48V series/parallel combinations.
Custom power options are available including DC/AC inverters, Thermoelectric generators, AC
standby generators etc.
Order Info:
Shipping box cover on pallet packaging for truck shipment. System is pre-wired, tested, burned-in for 24
hrs.
CSI Provides customer site surveys at no charge and engineering support for custom applications. Please
Call 800-274-0544 for tech. support.
Doc# 048–610–00/Nov.01.05