Appendix 11 WINDOW/DOOR SPECIFICATION PVC-U WINDOWS: CASEMENT & FULLY REVERSIBLE WINDOWS Standard: Manufactured to BS 7412: 2007 from white PVC-U extruded profiles of materials type A to BS EN 12608: 2003 (formerly BS 7413). Fully weather-stripped to B.S. 6375 Part 1 and BPF WG publication 345/1. Windows to be designed and installed to BS 8213-2004 code of practice for the safety in use and during cleaning of windows. Manufacturer: A firm currently registered under a quality assurance scheme operated by a certification and inspection body accredited by the United Kingdom Accreditation Service (UKAS) or equal approved. Installation to be in accordance with the British Plastics Federation Code of Practice for installation of PVC-u windows 357/1 (Existing dwellings) as far as practicable. To be supplied by Manufacturer holding 'Secured by Design' License all in accordance with BS 7950 to Ground Floor and vulnerable windows. Windows to be installed by Company registered with F.E.N.S.A. Operation and strength characteristics: To BS 6375-2: 2009. Profile / Reinforcement: Reinforced in accordance with BS 7412. Profile to be 60/70mm internally beaded PVCU “Profile 22” / LB Sheerframe or other approved. Glazing: Factory Glazed (unless size of window / Health & safety necessitates site glazing - to be agreed with C.A.) Double-glazed units internally beaded and manufactured in accordance with B.S EN 1279 (part 2): 2002 (KM36775) Glass in buildings: Insulated glass units and factory fixed in accordance with B.S 6262:1982 Code of practice for glazing for buildings (AMD 4063) (AMD 4582) (AMD 8279) (Partially superseded but remains current and is cited in building regulations). Toughened safety glass to be used in all critical locations as required by BS 6262 Part 4 and Building Regulations Approved Document N. Laminated glass to be used to all ground floor and vulnerable windows to provide enhanced security to meet Secured By Design specification. All safety glass (toughened and laminate) is to have a visible BS 6206 Kite Mark. NOT PROTECTIVELY MARKED Insulated panels to be composite PVCu skin, both sides bonded to 9mm moisture resistant MDF and EHDN polystyrene or BS (British Steel) Plastisol steel faced (leatherette finish) – white/white as standard. Ironmongery/ Accessories: All hinges to casement windows to be Securistyle Defender range. The “Defender Egress” to all 1st floor and above windows to open to a full 90° for emergency exit to comply with BS5588 Part 1: 1990 and Building Regulations Approved Document B for fire escape and allow cleaning access from inside the building to comply with BS8213: Part 1: 2004. A separate intuitive to release rebated Securistyle hook and peg child restrictor is also fitted and tested to BS6375 Part 2 to withstand a force of 600N when opened to the restricted position. The “Defender Standard” to all ground floor windows. All hinges used meet: Grade 4 BS EN 1670 minimum 180hrs corrosion resistance All hinges to fully reversible windows to be Yale G2475 Top Turn or PN UNI System or other approved. Handles to be Laird Security Hardware Charisma or a Trojan Hardware and Design Ltd. Sparta white polyester powder coated aluminium in line handles – key locking (to ground floor) and non-key locking (to 1st floor and above) or other approved. Sash lock to be the MACO Reverse Action In Line espagnolette locking mechanism, kite marked to BS7950 and “Secured by Design” approved and tested. Trickle Ventilation: Titon trickle ventilators or equal approved to be fitted as standard to meet Statutory Requirements. Permanent gas vents where appropriate to conform to Building Regulations Approved Document J and CORGI Essential Gas Safety- Third Edition 2002. Survey and Installation: To be carried out by a company accredited to BS Kitemark BPF W362/1 (KM94972) Survey and installation of Replacement Plastic Windows and Doors, or similar accreditation scheme approved by Contract Administrator. Installation to be in accordance with the British Plastics Federation Code of Practice for installation of PVC-u windows 357/1 (Existing dwellings). Fixing: Appropriate fixings to suit site conditions through window jambs or securely fixed using straps e.g. 115 x 10mm nylon frame fixing by 'Hilti' or equal approved. Spacing: When not predrilled or specified otherwise, position fasteners 150 - 250 mm from ends of each jamb, adjacent to each hanging point of opening lights, but no closer than 150 mm to a transom or mullion centre line, and at maximum 600 mm centres. Thermal Bridging: Ensure all thermal bridges at junctions of window frames and structure and any gaps in insulation should be treat as recommended by BRE paper Thermal Insulation: Avoiding Risks 3rd Edition. Thermal performance: BFRC/EST Energy Efficiency Rating of band “C”. NOT PROTECTIVELY MARKED Whole Window U-Value minimum 1.6W/msq.K. Designer to produce U-Value calculations for each window type on submission. Warranties: Minimum 10 years to include; Window assemblies (inc. installation), gaskets and weatherstrips, double glazing and ironmongery. SAMPLE OF STANDARD STYLE WINDOW WITH ASSOCIATED IRONMONGERY TO BE SUBMITTED TO YHN FOR APPROVAL PRIOR TO MANUFACTURE. SPECIFICATION OF IRONMONGERY TO ALL WINDOW DESIGNS/ STYLES TO BE ALSO SUBMITTED FOR APPROVAL. SECURED BY DESIGHN GRP DOOR SETS SPECIFICATION Description : Factory Double Glazed and Factory Finished Doors and frames Drawing reference(s): Door Choices -As separate drawing Manufacturer: 1/ See Manufacturers table below AND 2/ To be supplied by Manufacturer holding 'Secured by Design' License and door sets tested and passed at a UKAS accredited test house to PAS23-1:1999 and PAS24-1:1999. Warranties : minimum Rot & Fungal Attack to timber d/frame- 30 years Glazing System Failure - 10 years Manufacturing Defects - 10 years Door leaf warranty – 10 years Ironmongery - 10 years Factory Coatings - 10 years Construction: 44mm thickness Nan Ya or Capstone blank, consisting of 2mm thick thermoset resin glass reinforced polymer (GRP) wood grain effect finish skins. Compression moulded SMC to door pattern both sides of the door. Bonded to composite construction engineered sub-frame and timber/PVC composite styles and rails. CFC free injected polyurethane foam insulating core filled between the void of the skins. Specification is for guidance only. An equal and approved Specification from an approved supplier from the list provided is acceptable. Performance: Tested to B.S. 5368 Parts 1, 2. & to comply with BSI PAS 023 and PAS 024. Glazing details: 24/26mm obscure double glazed units if required by style. External pane to be 6.4mm laminated double-sided glazing tape/silicone bedded. Glazing beads to be fixed at 150mm centers and bedded in silicone. Frame: Timber – To be either Hardwood (Sapele) or softwood (Redwood). White microporous paint finish. Or: NOT PROTECTIVELY MARKED PVC-U – To be either Profile 22 60/70mm PVC-U frame system or Eurocell 70mm section to BS7413. Door Finish as delivered: 'Mahogany' or Microporous paint finish in colours as door drawing. Ironmongery: To PAS 23 and PAS 24. · Description: FRONT DOOR - 3 No. Specialist hinges (incorporating hinge bolts). *Multi-locking espagnolette system operated by key locking lever handles, low cill / threshold (to Part M ), letter plate ref. 'Paddock Fabrications' P209 Postmaster-gold anodized or ‘UAP Frame Master’ Ref. FMB1248G, Gold Anodized knocker c/w steel fixing bolts, 180 d. eye viewer, brass door chain, brass numerals, internal letter plate cover, gas ventilator. REAR DOOR - 3 No. Specialist hinges (incorporating hinge bolts). *Multi-locking espagnolette system operated by key locking lever handles. Ironmongery Specification: *Locking Mechanism to be: 'Fullex' SL-16 Crimebeater Multi-bolt locking system 'Hoppe' Tokyo Gold Anodised lever handles (CRBHAN0008), Solid spindle (SL97/ACO248), Cylinder Brass anti - Bump and anti-drill:M5 x 55 fixing screw with Cylinder guard ‘Fullex’ Crimebeater(70016) Threshold - (to meet Part M, Building Regulations) Other requirements: Supply and fix 10mm hardwood/PVC threshold timber (as necessary) to existing concrete cill (to ensure clearance of door). GAS REGULATIONS Front Door Frames to be packed at head as necessary to accommodate a 'Titon' Gas Regulations Ventilator Ref.7500 GR or similar to suit Gas Regulations (All by Door Supplier) Fixing: Door frames fixed at max. 600mm ctrs, 300mm from each corner. Weather-stripping: Schlegal Aquamac 21 or equal and approved. NOT PROTECTIVELY MARKED SECURED BY DESIGN LICENCE HOLDERS DOORS Contractor Warmseal Pendle Doorsets Ltd. West Port Roger Haydock & Co. Ltd. Permadoor Address Westway Industrial Park Ponteland Road Throckley Newcastle Upon Tyne NE15 9HW Navigation Road (off Lock Lane) Castleford West Yorkshire WF10 2LS Solway Industrial Estate Maryport CA15 8NF Telephone 0191 267800 Fax 0191 2648585 01977 518547 01977 604376 01900 814225 01900 818581 Mersey View Road Halebank Widnes Cheshire WA8 8LN Upton-upon-Severn Worcestershire WR8 0RX 0151 4252525 0151 4254141 01684 595200 01684 595200 At the time of writing all Companies are listed on either Secure by Design web site www. Securedbydesign.com . It is the Contractors’ responsibility to verify Contractors’ standing at the time of tender. The above list contains Manufacturers who have indicated they can meet the required performance criteria and specification and is for Contractor’s guidance only. Constructors may use other equal and approved Manufacturers providing they can meet the exact requirements of specification. NOT PROTECTIVELY MARKED DOOR CHOICES F1 F2 F3 FRONT DOORS R1 REAR DOORS R2 COLOURS- GLOSS:- Not e colours are t o ext ernal side of door only, int ernal face all whit e. RAL 9 0 1 6 WHITE RAL 9 0 1 7 BLACK RAL 3 0 1 3 RED RAL 5 0 0 4 BLUE RAL 6 0 0 9 GREEN MAHOGANY NOT PROTECTIVELY MARKED