MALDImatrixInfo wiki work1. Introduction Solid state diffuse refractance measurements of 6-aza-2-thiothymine (ATT), 2-amino-4methyl-5-nitropyridine (ANP) and 4-nitroaniline (4-NA) in tetrahydrofurane (THF), methanol (MeOH) and acetonitrile (CH3CN) Solid state refractance measurements of three matrices was performed with the utility of UV/VIS spectroscopy. Three different solvents were used to learn whether the crystallization from a different solvent has an effect on the solid state absorbance of the specific matrix. The structures of the three matrices studied are shown in Table 1. Table 1. Structures of the three matrices studied. IUPAC Name 6-methyl-3-thioxo-2H-1,2,4-triazin-5-one, ATT 4-methyl-5-nitro-pyridin-2-amine, ANP 4-nitroaniline, 4-NA Structure 2. Experimental 2.1. Materials Three matrices 6-aza-2-thiothymine (ATT, PN: 275514 lot #: 04415PD), 2-amino-4 methyl-5-nitropyridine (ANP, PN: 290092 lot #: 02022CA) and 4-nitroaniline (4-NA, PN: 185310 lot #: 03518EH) were purchased from Sigma-Aldrich, St.Louis, MO. Tetrahydrofurane (THF, CAS: 109-99-9, Lot # 16266PD), methanol (MeOH Chromasolv Plus for HPLC, CAS: 67-56-1) were purchased from Sigma-Aldrich and acetonitrile (CH3CN HPLC grade, CAS: 75-05-8, Lot # 965955) was purchased from FisherChemicals….. Fused silica microscope slides (S1-UV) were purchased from Esco Products, Inc. 2.2. Sample preparation 6-Aza-2-thiothymine sample solution was prepared by dissolving a solid matrix in 300 µL volume of THF to obtain saturated solution. The solution was prepared at room temperature in glass Fisherbrand*, class A clear borosilicate glass vials (GPI 8-425 thread; Capacity, 1/2 dr. (1.8mL); 12 x 35mm) purchased from Fisher Scientific, (Pittsburgh, PA). It was vortexed for approximately 10 minutes and left overnight. The solution was then vortexed for another 10 minutes again to ensure that the excess of the solid matrix is still in the solution. Such solution was centrifuged for 14 minutes at 5000 rpm. The supernatant was deposited on the microscope slide and solvent allowed to evaporate. UV/VIS measurements were performed on the solid sample spot. The remaining matrices were prepared accordingly in THF, MeOH and CH3CN. 2.3. Instrumentation Eppendorf AG Centrifuge 5418 (Hamburg) was used to centrifuge the saturated matrix solutions. Saturated solutions were mixed on a FIsherScientific Vortex Genie 2. All the spectrophotometric measurements were performed on Perkin-Elmer, Inc. (Shelton, CT) Lambda-950 UV/Visible Absorption Spectrophotometer. 2.4. Data Analysis UV/VIS spectra were acquired with a PerkinElmer UV WinLab 5.1.5.0637 software. Absorption scan was performed from 200 nm to 800 nm wavelength. 3. Results and Discussion Solid State Absorbance-microscope slide 0.18 0.16 Absorbance 0.14 0.12 0.1 0.08 fused silica 0.06 0.04 0.02 0 150 350 550 Wavelength [nm ] 750 950 Spectralon disc 0.004 Absorbance 0.003 0.002 0.001 0 -0.001 Series1 0 200 400 600 800 1000 -0.002 -0.003 Wavelength [nm] Solid State 4-NA in CH3CN Absorbance 0.9 0.8 0.7 0.6 0.5 0.4 4-NA CH3CN 0.3 0.2 0.1 0 180 380 580 Wavelength [nm] 780 980 Solid State 4-NA in THF 1.4 Absorbance 1.2 1 0.8 4-NA in THF 0.6 0.4 0.2 0 180 380 580 780 980 Wavelength [nm] Solid State 4-NA in MeOH 0.6 Absorbance 0.5 0.4 0.3 4-NA in MeOH 0.2 0.1 0 180 380 580 780 Wavelength [nm] 980 Absorbance Solid State ATT in CH3CN 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 180 ATT in CH3CN 380 580 780 980 Wavelength [nm] Solid State ATT in THF 0.8 0.7 Absorbance 0.6 0.5 0.4 ATT in THF 0.3 0.2 0.1 0 180 380 580 Wavelength [nm] 780 980 Solid State ATT in MeOH 0.8 0.7 Absorbance 0.6 0.5 0.4 ATT in MeOH 0.3 0.2 0.1 0 180 380 580 780 980 Wavelength [nm] Solid State ANP in CH3CN 0.7 Absorbance 0.6 0.5 0.4 ANP in CH3CN 0.3 0.2 0.1 0 180 380 580 780 980 Wavelength [nm] Absorbance Solid State ANP in THF 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 180 ANP in THF 380 580 780 Wavelength [nm] 980