WILLIAM B. MONROE 2709 W. Klamath Ave Kennewick, WA. 99336 Cell Ph: (509) 830-1726 / wbm60@hotmail.com Work Ph: (509) 373-3118 / william_b_monroe@rl.gov DESIGNER CAD EMPLOYMENT HISTORY: 2010-2012: Designer, Contract design for CHPRC, Richland, WA. 200W Pump & Treat Facility, multi-disciplined design work; Civil, Structural, Architectural, Mechanical, Electrical, Piping, HVAC, P&IDs, I&C, Facilitating Engineering staff with design development & modifications, documenting DCN, Redline & As Builts Field notes. 2010: Designer, Contract design for Energy Solutions, Richland, WA. Mechanical Design components for use at the Tank Farms at a former Nevada Nuclear test site - Structural construction detail facility for drying and packaging Nuclear Waste Materials. 2009: Designer, ARES Corp., Richland, WA. P&IDs, System upgrades for the National Energy Technology Laboratory (NETL) facility in Albany, OR. Standardizing and formalizing compressed gas system installations and tubing runs. 2008: Designer, Contract w/Westinghouse Corp., Richland, WA. Electrical enclosures and panel layouts, wiring schematics. 2007: Designer, Parsons TD&FC, Pasco, WA. Utilization of SolidWorks in the development of complex solid modeling of machine parts & assys. AutoCAD layouts of PFDs, P&IDs & Hydraulic Schematics. 2006: Designer, Contract design work for Idaho National Laboratory (INL) Preliminary design of a Remote Treatment Project: Demolition of existing facilities, termination of existing utilities, locating and design of new facility foundations. Design and location of a Decontamination Spray Chamber, design of hatch opening & related equip. Layout & location of Fire Protection piping, hydrants throughout site and internal building piping. Multidiscipline peer review of all outgoing drawings for accuracy and presentation. 2005: Designer, Columbia Energy & Environmental Services, Richland, WA. Mechanical designs (5) of Vortex Cyclones for AMEC to be used in the process of a Demonstration Bulk Vitrification (DBV). Design of systems for extraction of Nuclear Waste Storage from single walled to double walled tanks. Civil Site Plan layouts, Control Trailer & Skid assys & details, Installation dwgs & details, Mechanical & Electrical interface, Equipment details, Weldments, Assys, Piping, Hoses, P&IDs. PFDs, Spool assys. Filter Skids to be used for (DBV) & for ongoing projects at the Tank Farms. Also Instrument Enclosure layouts & diagrams, Panel Board Schedules, Conduit Runs, Wiring diagrams, Heat trace dwgs, PLCs, Loop diagrams, One line diagrams, Grounding layouts, Audio/Video system diagrams, Control panels. 2004: Designer, AECOM (DMJM TECHNOLOGY): Demonstration Bulk Vitrification System proposal for CH2M Hill: Columbia Energy & Environmental Services: Tank Farms Salt Cake removal proposal for CH2M Hill: Fluor Hanford: K Basins Sludge Removal. 2003: Designer, ANP (SIEMANS/FRAMATONE), Richland, WA. Designed a next generation Nuclear Fuel Pellet cartridge loader and inspection conveyor. 2002: Designer Fluor Hanford: 100K Basins, Coordinated assignments & assisted with project &/or computer related questions/problems. Peer Review (Checking) drawings & designs (Hanford & outside vendors) for Fuel Retrieval System (FRS), Canister Cleaning System (CCS), Fuel Transfer System (FTS), Sludge Transfer System (STS), Sludge Water System (SWS); Primary designer for fast track build & install Sludge Waste System (SWS) Truck scale system. Ongoing design reviews & facility design modifications & documentation (FMP’s) to ensure that newly introduced processes & procedures & support systems function properly. Familiar with Nuclear Facility Codes, Regulations & Procedures. Design Glovebox latching device. Design Yoke lifting device, utilized as a nuclear waste container liner hoist. 2000: Designer, BNFL Inc. / Idaho National Engineering & Environmental Laboratory (INEEL): Design hydraulic drum lid sealing mechanism. Design shipping / storage containers for transuranic nuclear waste / crushed 55 gallon drums (pucks). 1999: Designer, Fluor Hanford: As-built, field verification program of Cold Vacuum Drying Facility (CVDF), & IWTS 105KW, Walk-down verification of mechanical & electrical systems, write & incorporate Engineering Change Notices. Design & documentation of tools used to categorize fuel basin sludge & scrap. Canister Storage Building (CSB) update dwgs with relevant as built information. 1998: Designer, Sonico Inc: Moses Lake, WA. Developed special repairs for a wide variety of Boeing & McDonnell Douglas aircraft. Mechanical items/devices & structures, including hydraulic & structural members, wing & flap components, A myriad of materials, honeycomb, fiberglas, Kevlar & various metals. Acted as liaison with Boeing’s Engineering Department & other aircraft component manufacturers to ensure that repair scenarios would qualify for necessary air worthiness criteria. 1997: Designer, Chem Nuclear Inc., & Los Alamos Technical Associates (LATA): Piping layouts for Integrated Water Treatment System for 105KW & Facility layout of an annex to be used for Ion Exchange Modules (IXMs). Prepared a layout for hydro cyclones & associated piping used as an integral component of sludge removal. Conceptual design & layout of filter & ventilation systems, associated ducting, shielding walls, ceilings. Design storage tank Sludge Weight and Liquid Level Tape Removal Reel. 1993-1996: Designer, Contracted to; Westinghouse Hanford & Kaiser Engineers Hanford (ICF-KEH): Documentation of existing Essential Systems for all of the 100-K Basin area; 100KE, 100KW reactor bldgs, SNF Pools, all supporting facilities. Field walk down verification of as-installed piping systems, spent nuclear fuel canister racks, & other mechanical devices & assemblies. Developed "as-found" piping & instrumentation diagrams (P&IDs) & other mechanical systems. Provided engineering support for the design of SNF Storage Basin Isolation Barriers. VOCATIONAL TRAINING: Microsoft Office 2007: Windows XP, Word, Excel, PowerPoint, Access & Outlook, AutoCAD 3D: Columbia Basin College, Pasco, WA. AutoCAD: Renton Technical College, Renton, WA. AutoCAD: Lake Washington Technical College, Kirkland, WA.