Magnetic Anisotropy Studies on Pulsed Electrodeposited Ni/Cu/Ni Trilayer K. Dhanapal1, D. Prabhu2, R. Gopalan2 V. Narayanan3, A. Stephen1* 1 Materials Science Centre, Department of Nuclear Physics, University of Madras, Guindy Campus, Chennai 600 025, India 2 Centre for Automotive Energy Materials, ARCI, Taramani, Chennai-600113 3 Department of Inorganic Chemistry, University of Madras, Guindy Campus, Chennai-600 025, India * Corresponding author’s e-mail: stephen_arum@hotmail.com, Tel.: +91-4422202802; Fax: +91-4422353309 Abstract Results and Discussion The prediction of Neels about the surface anisotropy increases great interest on preparation of multilayers with magnetic and non-magnetic layer. The pulsed electrodeposition method was employed for the deposition of pure Ni, Ni/Cu and Ni/Cu/Ni films. This pulsed electrodepostion method has greater advantages while comparing with other methods. The X-ray diffraction pattern confirms the formation of fcc structure for both nickel and copper. The cross sectional scanning electron microscopy shows the layer formation in Ni/Cu and Ni/Cu/Ni films in layered nature. The vibrating sample magnetometer was employed to determine magnetic anisotropy behaviour of the layered films. It is observed that the easy axis is in plane of the film for all the films. The XRD pattern of pure Ni, Ni/Cu and Ni/Cu/Ni is shown in the Fig 1. The pattern clearly shows the formation of nickel and copper in bulk nature along with high crystallinity. The cross sectional view of pure Ni, Ni/Cu and Ni/Cu/Ni layered films shows that pure Ni have smooth surface and having 13µm thickness. The hysteresis loop is taken for two different orientation. The hysteresis loop for all the three films show the anisotropy behavior and maximum of -2.04X103 J/m3 anisotropy energy is obtained for Ni/Cu/Ni layer Keywords: Pulsed Electrodeposition, magnetic anisotropy, metallic copper, trilayer film, polycrystalline anisotropy Introduction The multilayer with magnetic and non-magnetic layers has greater advantage and greater application like magnetic storage. The layer thickness determines the perpendicular anisotropy in the multilayer systems. The perpendicular anisotropy is defined as, when the easy magnetization axis of the multilayers is perpendicular to the plan of the multilayers so that the saturation magnetization attained for less field. Sputter deposited Co/Pd multilayer was the first reported material which have perpendicular anisotropy. The possible mechanism for the occurrence of perpendicular anisotropy is reduced symmetry at the interface, shape anisotropy and magnetostriction. Materials and Methods The pure Ni, Ni/Cu and Ni/Cu/Ni layered films were prepared using pulsed electrodeposition method. The stainless steel of grade 316L was used as a cathode in conventional two electrode system. Nickel is deposited from nickel sulphate bath and copper from copper chloride bath. The deposited film were subjected to various characterization like XRD, Cross sectional SEM and VSM. Fig. 1: XRD pattern of pure Ni, Ni/Cu and Ni/Cu/Ni layered films. Conclusion The Ni/Cu and Ni/Cu/Ni layered films where successfully deposited using pulsed electrodeposition method. The XRD pattern confirms the formation of nickel and copper in bulk nature with high crystallinity. The layered nature along with rough interface between the layers was studied from SEM. The anisotropy behavior of the magnetic and non-magnetic layer was studied using VSM. Acknowledgment Author acknowledge National Centre for Nanoscience and Nanotechnology, University of Madras for financial support.