Schedule of Technical Facilities The Loch Suite The Lomond Auditorium Specific details of the technical services and facilities included within the hall are detailed below. Additional facilities can be provided and the S.E.C.C would be pleased to provide a quotation for specific requirements. 1. Seating Theatre style seating, capacity 624 on one level consisting of: 435 tiered seats on a retractable seating system. 182 floor level seats. 7 wheelchair locations. 2. Equipment Access Vehicle access to auditorium via covered loading bay. Auditorium access door 2.5m (w) x 3m (h). 3. Suspension 2 x Slick Minibeam trusses rigged over stage area. Loading 500kg evenly distributed. 2 x Slick Minibeam FOH lighting trusses rigged on motorised hoists over auditorium. Loading 500kg evenly distributed. 4. Staging Carpeted de-mountable stage 18.85 (w) x 4.9m (d) x 0.9m (h) - (61’ x 16’ x 3’). Set of black velour curtains at rear of stage. LED lit Lectern housing 21.5” Touch confidence monitor and 24” Signage monitor Note – Graphics for signage monitor should be 16:9 PowerPoint presentation. Three top table units. White Cyclorama. 5. Lighting Dimmable LED auditorium lighting. Comprehensive stage lighting facilities are provided, rigged to a standard layout for conferences and presentations, consisting of the fixtures in the plan below: 6. Sound Comprehensive sound facilities are provided for conferences and presentations consisting of the following: DiGiCo SD9 sound mixer. 1 x Klark Teknik DN 360 graphic equaliser. 1 x Tascam audio cassette machine. 1 x Denon CD player. 1 x Sony minidisc recorder. Up to 4 cabled Q & A microphones, 4 top table microphones, 2 lectern microphones and 2 radio microphones are available. Loudspeaker coverage is provided from a flown speaker array consisting of 16 x Nexo Geo Loudspeakers hung 8 either side of stage on the first FOH lighting truss. Audio tie lines link all areas of the stage and auditorium to the sound control room and further tie lines link to and from other halls within the centre. A Tecpro performance communications system is available with up to 6 portable outstations. 7. Projection Projection facilities are provided for conferences and presentations consisting of the following: Flown front projection screen - Projection area 12m x 4m - Hung at rear of stage. 2 x Christie 8.5K video/data projector edge blended installed within the Control Room. Nextstage 16 Seamless switcher/edge blender. Networked PC running Windows and PowerPoint with dual Technician/Lectern Control. 21.5” LCD Touch Confidence monitor mounted on into the lectern. 24” LCD Signage monitor on the front of the Lectern. 40” LCD confidence monitor in front of top table. 2 x Cannon XF105 cameras. 1 Locked off as a wide shot, 1 locked off on Lectern. Camera person POA. 1 x Laser pointer. Note: Background graphics should be done in a 3:1 aspect ratio. PowerPoint and camera will be displayed in a 4:3 windows within the background as per the example above. Video tie lines link all areas of the stage and auditorium to the control room and further tie lines link to other halls within the centre. 8. Communications Data circuits can be installed in the Hall and Foyer areas of the centre subject to an additional charge. 9. Power supplies Stage 1 x 200A three phase supply. 1 x 63A three phase supply. Control Room 1 x 63A three phase supply. Use of these supplies is subject to an additional charge. 10. Staffing Two Technicians are provided to set up and operate the equipment defined above, and are assigned to the Hall for up to ten continuous working hours (excluding meal breaks) within each tenancy day. Additional Technical staff can be provided subject to an additional charge. 11. Other layouts POA