Please INSERT ORGANIZATION NAME QUALITY MANAGEMENT SYSTEM insert LOGO Document Code (Number): EG.OP.09 First valid effective date and revision number: Previous revision effective date and revision number This revision effective date and revision number Status: Title: Insert first effective date and revision number as YYYY-MM-DD / Rev. Insert first previous date Nr. revision number as and YYYY-MM-DD / Rev. Insert this date and Nr. effective revision number as select ACTIVE / DRAFT YYYY-MM-DD / Rev. Nr. Validation of calibration instructions Prepared by: (Signature) (E.g. Quality Management Supervisor) (Title) (Date) Revised: (Signature) (E.g. Electronics Group Head) (Title) (Date) Approved by: (Signature) (E.g. Director of the Organization) (Title) (Date) EG.OP.09 DATE/REVISION 1 of 5 EG.OP.09 DATE/REVISION 2 of 5 1. Title: VALIDATION OF CALIBRATION INSTRUCTIONS. 2. Purpose: To define the set of procedures for the verification of the adequacy of the results obtained by using a calibration instruction adopted from a third party developer. 3. Scope: The scope of this procedure extends to all of the electrical calibrations instructions adopted by the EG from other developer sources. 4. Definitions: Verification operations: Initial visual inspection and performance tests that serve to evaluate the functionality of the instrument under calibration. Calibration operations: Set of measurements or actions aimed to verify the instrument performance in measurement, functionality of operational modes and other characteristics of the instrument under calibration. Calibration result: Reported value that serves to evaluate the fitness for purpose of the measurement results. Uncertainty: A parameter associated with the result of a measurement that characterises the dispersion of the values that could be reasonably attributed to the measurand. 5. References: ISO GUM: 1995, Guide to the expression of uncertainty in measurement. EA-4/02, Expression of the uncertainty of measurement in calibration, European Co-operation for accreditation, December 1999. VDI/VDE/DGQ/DKD 2622. Calibration of measuring equipment for electrical quantities. Part 1 Fundamentals, January 2001. EG.OP.06 EG.OP.07 EG.OP.08 6. Responsibilities: The EG Technical staff members are responsible for the assessment of the validity of any electrical calibration instruction adopted from external developer and implemented in the EG. The Technical Leader of EG has the responsibility of reviewing the performance characteristics and estimation of the uncertainty performed during instruction validation, as well as to review and approving all the validated calibration instructions. EG.OP.09 DATE/REVISION 3 of 5 7. Procedure: 7.1 Confirmation of identity and specificity: The first step in the verification procedure starts from checking the compliance of the instrument definition characteristics with those assumed in the instruction. Instrument denomination, model, description of the main features of operation shall match with those assumed in the procedure. Otherwise, the procedure shall de modified by making proper adjustments. A statement of the modifications made shall be included in a verification report. For example, the amount of working scales and their minimal and maximal values specified in the instruction shall correspond to those observed in the instrument. The uncertainties of the measurement stated in the instrument technical specifications shall match with those assumed in the instruction. 7.2 Verification operations. The calibration instruction shall comprise initial verification inspections to assess the instrument functionality before proceeding to the operation. If such operations are not addressed in the instruction, make annotation in the verification report, and relate the modifications made to the instructions as to include such. 7.3 Calibration operations. 7.3.1 Primary measurements. Verify that the measurements corresponding to evaluate the indication of each magnitude are defined as to cover all of the working scales, reference values being selected as to correspond to approximately 80 % of the maximal value of a given scale. Each set of measurements shall include no less than 10 replicates. Annotate the results in the verification report. 7.3.2 Calibrator control. Verify that the instruction includes actions to verify the trueness of the calibrator reference value. Follow the instructions for IQC practice from EG.OP.06 and compare the obtained value and uncertainty with those corresponding to the calibrator nominal values in the verification report. 7.3.3 Uncertainty estimation: Calculate the uncertainty of the measured values following the recommendations given in the operational procedure EG.OP.08. The utility worksheet EG-UNC.xls can be used for this purpose. Compare the results obtained with those obtained by the instruction recommendations and make an evaluation statement in the verification report. In case of discrepancies, change the instruction as to obtain the values calculated according to EG.OP.08 procedure. 7.3.4 Report of results and calibration certificate: Verify if the format for reporting the results provided by the instruction under verification corresponds to the conditions specified in EG.OP.07. Make corrections if necessary and annotate such actions and the obtained results in the verification report (EG.OF.16) that must be filed in record EG.OR.16. 7.3.5 Additional actuators verification. Verify if actions are addressed to check the proper functioning of other actuators in the instrument which are relevant for its intended use (operation mode, threshold, EG.OP.09 DATE/REVISION 4 of 5 sensitivity, etc.). Annotate the obtained results in the verification report. 7.4 Statement of validity. Declare the validity of the verified instruction (and modifications included) in the verification report. 8. Records and forms: 9. Utilities EG.OR.16 EG.OF.04, EG.OF.16, EG.OF.08 EG-UNC.XLS EG.OP.09 DATE/REVISION 5 of 5