HOWMEDICA DIV OF PFIZER HOSPI -- 6196-5-010 SURGICAL ANTIBIOTIC SIMPLEX BONE C ======================================================= MSDS Safety Information ======================================================= MSDS Date: 03/18/1998 MSDS Num: CJCYM Product ID: 6196-5-010 SURGICAL ANTIBIOTIC SIMPLEX BONE CEMENT DUTCH LAN MFN: 06 Responsible Party Cage: 64394 Name: HOWMEDICA DIV OF PFIZER HOSPITAL PROD GROUP INC Address: 359 VETERANS BLVD City: RUTHERFORD NJ 07070 Emergency Phone Number: 201-507-7516 Review Ind: Y Published: Y ======================================================= Contractor Summary ======================================================= Cage: SO006 Name: AFIERA/RSH AIR FORCE SAFETY & HEALTH ANNA WILLIS Address: 2513 KENNEDY CIR BLDG 180 RM 134 City: BROOKS AIR FORCE BASE TX 78235-5123 Phone: 210-536-6159, DSN 240-6159 Cage: 64394 Name: HOWMEDICA DIV OF PFIZER HOSPITAL PROD GROUP INC Address: 359 VETERANS BLVD City: RUTHERFORD NJ 07070 Phone: 201-507-7796/201-507-7300 ======================================================= Ingredients ======================================================= Cas: 80-62-6 RTECS #: OZ5075000 Name: METHYL METHACRYLATE Percent by Wt: 97.5 OSHA PEL: 410 MG/M3;100 PPM ACGIH TLV: 410 MG/M3;100 PPM ACGIH STEL: NOT ESTABLISHED EPA Rpt Qty: 1000 LBS DOT Rpt Qty: 1000 LBS -----------------------------Cas: 99-97-8 RTECS #: XU5803000 Name: N,N-DIMETHYL-P-TOLUIDINE Percent by Wt: 2.5 -----------------------------Cas: 123-31-9 RTECS #: MX3500000 Name: HYDROQUINONE OSHA PEL: 2 MG/M3 ACGIH TLV: 2 MG/M3 ACGIH STEL: NOT ESTABLISHED EPA Rpt Qty: 1 LB DOT Rpt Qty: 1 LB ======================================================= Health Hazards Data ======================================================= Route Of Entry Inds - Inhalation: YES Ingestion: YES Effects of Exposure: INHALATION: RESPIRATORY IRRITANT. SKIN: SLIGHT IRRITATION. MAY CAUSE ALLERGIC SENSITIZATION TO SOME PEOPLE. REPEATED EXPOSURE MAY CAUSE DERMATITIS. EYES: MODERATE IRRITANT. INGESTION: IRRITATION OF TH E GASTROINTESTINAL TRACT. Signs And Symptions Of Overexposure: IRRITATION, DIZZINESS, DROWSINESS, CONFUSION, UNCONSCIOUSNESS First Aid: INHALATION: REMOVE TO FRESH AIR. KEEP WARM & AT REST. LOOSEN CLOTHING. GIVE OXYGEN/CPR IF NECESSARY. SKIN: WASH W/SOAP & WATER FOR SEVERAL MINS. EYES: WASH IMMEDIATELY W/COPIOUS AMOUNTS OF CLEAN WATER /SALINE EYEWASH SOLUTION FOR 15 MINS. INGESTION: DON'T INDUCE VOMITING. ENSURE A CLEAR AIRWAY. IF CONSCIOUS, WASH OUT MOUTH W/WATER & GIVE 200-300 ML OF WATER TO DRINK.OBTAIN MEDICAL ATTENTION IN ALL CASES. MEDICAL ADVICE: SYMPTOMATIC TREATMENT AS INDICATED. FOLLOWING INGESTION, ABSORBENTS SUCH AS ACTIVATED CHARCOAL MAY BE OF VALUE. GASTRIC LAVAGE MAY BE EFFECTIVE WHEN PERFORMED W/IN 4 HOURS OF IN GESTION. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: ELIMINATE IGNITION SOURCES. ENSURE PERSONAL PROTECTION. WEAR APPROPRIATE RESPIRATORY PROTECTIVE EQUIPMENT. PREVENT ENTRY INTO DRAINS. ABSORB ONTO SAWDUST/OTHER COMBUSTIBLE MATERIALS. TRANSFER TO A SUI TABLE NON-FLAMMABLE CONTAINER FOR DISPOSAL/RECOVERY Waste Disposal Methods: DISPOSE OF IN ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS. Handling And Storage Precautions: BOTH POWDER & LIQUID COMPONENTS MUST BE STORED IN ITS ORIGINAL PACKAGING IN DARK, DRY CONDITIONS BELOW 77F. AS THE PRODUCT IS MANUFACTURED STERILE, IT MUST ONLY BE OPENED BY TRAINED OPERATING THEATRE STAFF. Other Precautions: AVOID EXPOSURE TO DUST & VAPORS. PROVIDE ADEQUATE VENTILATION IN THE WORK AREA. WEAR SURGICAL GLOVES. DON'T ALLOW THE LIQUID TO COME INTO CONTACT WITH/BE ABSORBED BY THE BODY. WEAR EYE & HAND PROTECTI ON WHEN OPENING THE AMPOULE. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point: =11.5C, 52.7F Flash Point Text: ABEL CLOSED CUP Autoignition Temp: =421.C, 789.8F Lower Limits: 2.1 Upper Limits: 12.5 Extinguishing Media: CO2, FOAM, DRY POWDER/BCF (BROMOCHLOROFLUOROCARBON) MEDIA Fire Fighting Procedures: LIQUID IMMISCIBLE W/WATER. LIQUID FLOATS ON WATER. Unusual Fire/Explosion Hazard: LIQUID MAY POLYMERIZE ON HEATING. SEALED CONTAINERS MAY RUPTURE EXPLOSIVELY IF HOT. ======================================================= Control Measures ======================================================= Respiratory Protection: REQUIRED Ventilation: ADEQUATE VENTILATION Protective Gloves: REQUIRED Eye Protection: REQUIRED Work Hygienic Practices: REMOVE/LAUNDER CONTAMINATED CLOTHING & SHOES BEFORE REUSE. WASH W/SOAP & WATER FOR SEVERAL MINS. Supplemental Safety and Health: DON'T WEAR SOFT CONTACT LENSES IN THE WORKING AREA AS THEY MAY BE DAMAGED BY METHYL METHACRYLATE VAPOR. ======================================================= Physical/Chemical Properties ======================================================= Boiling Point: =100.5C, 212.9F Solubility in Water: SLIGHTLY-1.6% Appearance and Odor: CLEAR COLORLESS FLAMMABLE LIQUID W/PUNGENT CHARACTERISTIC SLIGHTLY SWEET ODOR ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: HEATING, SUNLIGHT Materials To Avoid: CATALYSTS, STRONG ACIDS, ALKALIS/OXIDIZING AGENTS Hazardous Polymerization Indicator: YES Conditions To Avoid Polymerization: SUSCEPTIBLE TO POLYMERIZATION INITIATED BY PROLONGED HEATING, THE PRESENCE OF A CATALYST/EXPOSURE TO SUNLIGHT. ======================================================= Toxicological Information ======================================================= Toxicological Information: EXPOSURE TO METHYL METHACRYLATE MONOMER MAY CAUSE IRRITATION, CNS EFFECTS & ALLERGIC SKIN REACTIONS (SENSITIZATION); IT MAY ALSO CAUSE LIVER & KIDNEY TOXICITY, LUNG CONGESTION & HEART FAILURE. N,N-DIM ETHYL-PARA-TOLUIDINE MAY CAUSE IRRITATION. IT IS RAPIDLY ABSORBED THROUGH THE SKIN & MAY CAUSE A SYSTEMIC BLUISH DISCOLORATION OF THE SKIN, ESPECIALLY EVIDENT UNDER THE FINGER & TOE NAILS (CYANOSIS). ======================================================= Ecological Information ======================================================= Ecological: NO DATA ARE AVAILABLE ON THE ADVERSE EFFECTS OF SURGICAL SIMPLEX BONE CEMENT PRODUCTS ON THE ENVIRONMENT. ======================================================= MSDS Transport Information ======================================================= Transport Information: THE LIQUID COMPONENT OF SURGICAL SIMPLEX BONE CEMENTS ARE CLASSIFIED AS HAZARDOUS MATERIALS FOR SHIPPING UNDER THE INTERNATIONAL AIR TRANSPORT ASSOCIATION DANGEROUS GOODS REGULATIONS. SHIPPING NAME: M ETHYL METHACRYLATE MONOMER, INHIBITED. HAZARD CLASS: FLAMABLE LIQUID. ID NUMBER: UN1247. TRANSPORTATION BY LAND/SEA IS NOT RESTRICTED, PROVIDED THAT THE PRESENCE OF THE MONOMER IS NOTIFIED TO THE CARR IER AT THE TIME OF SHIPMENT. ======================================================= Regulatory Information ======================================================= State Regulatory Information: SURIGICAL SIMPLEX P RADIOPAQUE BONE CEMENT IS MANUFACTURED UNDER THE CONTROLS FOR MEDICINAL PRODUCTS. IT IS CLASSIFIED AS A PHARMACY MEDICINE. UPON ADOPTION OF THE EU MEDICAL DEVICES DIRECTIVE SURGICA L SIMPLEX P RADIOPAQUE BONE CEMENT WILL BE A CLASS IIB MEDICAL DEVICE. ======================================================= Other Information ======================================================= Other Information: THIS INFORMATION IS FURNISHED W/O WARRANTY, EXPRESSED/IMPLIED EXCEPT THAT IT IS ACCURATE TO THE BEST KNOWLEDGE OF HOWMEDICA INTERNATIONAL INC. THE DATA ON THIS SHEET RELATE ONLY TO THE SPECIFIC MATERI ALS DESIGNATED HEREIN. HOWMEDICA INTERNATIONAL INC. ASSUMES NO LEGAL RESPONSIBILITY FOR THE USE/RELIANCE UPON THESE DATA. ======================================================= HAZCOM Label ======================================================= Product ID: 6196-5-010 SURGICAL ANTIBIOTIC SIMPLEX BONE CEMENT DUTCH LAN Cage: 64394 Company Name: HOWMEDICA DIV OF PFIZER HOSPITAL PROD GROUP INC Street: 359 VETERANS BLVD City: RUTHERFORD NJ Zipcode: 07070 Health Emergency Phone: 201-507-7516 Label Required IND: Y Date Of Label Review: 02/03/1999 Status Code: A Origination Code: G ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.