clean technology. - Invest Bhubaneswar

advertisement
CLEAN TECHNOLOGY.
Any Product, Service And Process That Delivers
Or Adds Value By Raising Productivity And Product
Performance Using Limited Non Renewable Or Natural
Resources Creates Significantly Less Waste Than
Conventional Offerings And Impacts On Environment
And Public Health.
WHY CLEAN TECHNOLOGY.
ENERGY PRICE SPIKE.
RESOURCE SHORTAGE.
GLOBAL ENVIRONMENTAL PROBLEM.
(CLIMATE CHANGE & GLOBAL WARMING)
MAJOR CLEAN TECHNOLOGY SECTORS.
Waste Water (Grey Water)- Recycle &Reuse
Waste To Energy (Municipal, Flue Gases)
Green Building & Green Transportation.
Renewable Energy (Solar,wind,Bio Fuels,Bio Mass)
OUR MISSION
To Promote Adoption Of Renewable Energy to Reduce the
Human Ecological Footprint, Using Proven Technologies,
high Quality Engineering And Professional Installation
Practices. We Enable Our Society in Transition To Clean
Energy.
Annual mean solar radiation in India
in (kwh/sq.m/day)
Some Idea About Solar System.
The launch of the National Solar Mission (JNNSM)12th
January 2010 has given a big impetus to solar energy in India.
The highlights of the mission are given below:
1.
Installed capacity of 20000 MW by 2022
2.
Establishment of a single window investor friendly
mechanism
3.
Envisages an investment of Rs 90,000 crores over the
next 30 years
4.
Initial investment of Rs 4,337 crores provided by the
Government of India
Target for the First Phase of the Mission
1.
Total target for power generation 1st Phase
(ending 2013): 1,300 MW (PV)
2.
Grid Connected (33 kV): 1,000 MW (PV)
3.
Rooftop PV and Small Solar: 100 MW
4.
Off-Grid PV Applications: 200 MW
Break –up for The Capital Expenses Per MW :
Component
PV Modules
Balance of System
(transformers, cables and
wires, tracking devices…)
Installation (civil &
general works)
Inverter
Others (evacuvation and
other pre operative
expenses)
Total
Amount (lakhs)
Percentage
600
50%
200.0
110.0
35%
90.0
110.0
1,110.0
15%
Capital Cost for Solar PV in
2011
Capacity (MW)
REC tariff for solar power
Solar
REC
(INR /
Mwh)
Capex (Rs
Crores/MW)
1
11.1
5
54.4
10
103.3
15
152.3
20
196.3
Upto 2012 2012 - 2017
CERC Price
17000
13400
Floor Price
12000
9300
SNM SOLAR PLANT
SNM GROUP.
Main Entrance Of Power Plant.
One Mega Watt Control Room
P.V. modules. Placed 20 degree. facing towards south.
Photovoltaic MODULE
RATING.= 230 Watt.
V(max.)=
29.1 v
I (max.)=
7.9 amp.
No. of pv used= 4400
Total capacity= 1mw
22 pv module forms one string having capacity of 5kw
which is then connected in parallel with the other strings, in
a string combiner box. Likewise there are 200 strings placed
parallely.
String combiner box which combines 6 to 10 strings
of an array according to the design.
Main junction box a and b is a junction box in between array
area and inverter it divides the array into two equal parts
having 500kw capacity each.
Inverter 1 and 2 having capacity of 500kw each. Which
converts dc power to ac power. Out put voltage 300v (A.C)
Grid synchronization is also done at inverter level
Compact substation . Capacity 1250kva, 0.3/11kv
which steps up the voltage level to 11kv for
Transmitting the power towards grid.
P.L.C and SCADA for remote monitoring of all
the equipments and generation details.
WEATHER MONITORING STATION
SINGLE LINE DIAGRAM.
Sun is an inexhaustible source of energy but till the last
decade its use was not widespread .
SNM Solar has come up with a new project of
capturing and supplying solar energy to serve the
society.
Thank you…