Sentron Molded Case Circuit Breakers s s Full Line Sentron Series ON ON 45 3 6 7 2 LO HI CQD 100A 1,2,3P ED 125A 1,2,3P ON 45 3 6 7 2 HI LO 45 3 6 7 2 HI LO 3 2 LO 45 6 7 HI 45 3 6 7 2 HI LO 45 3 6 7 2 HI LO 45 3 6 7 2 LO HI 45 3 6 7 2 LO HI JD 400A 2,3P 45 3 6 7 2 LO HI 45 3 6 7 2 LO HI LD 600A 2,3P 45 3 6 7 2 LO HI 45 3 6 7 2 LO HI ON ON 3 2 LO 45 6 7 HI ND 1200A 2,3P 45 3 6 7 2 HI LO 45 3 6 7 2 HI LO 45 6 3 7 2 HI LO PD 1600A 2,3P DPD Marketing 45 3 6 7 2 HI LO 45 3 6 7 2 HI LO 3 2 LO 45 6 7 HI RD 2000A 2,3P 45 3 6 7 2 LO HI LMD 800A 2,3P ON ON MD 800A 2,3P V:\Wendt FD 250A 2,3P 45 3 6 7 2 LO HI ON TD 3200A 3P s Interrupting Ratings @ 480 V Frame CQD 100 ED 125 FD 250 JD/ LD 600 LMD 800 MD/ ND 1200 PD 1600 RD 2000 STD 3200 Standard 14KA 25KA 35KA 35KA 50/65KA 50KA 50KA 50/65KA 65KA * Highest 200KA 200KA 150KA 100KA 100KA 150KA * No fuses required V:\Wendt DPD Marketing s Sentron Features • • • • • • • • • CE marking IEC interrupting ratings Full line current limiting Thermal mag from 15 to 2000A Electronic from 40 to 3200A 100% rated frames available 50C Available 400Hz available Standard fungus resistant design V:\Wendt DPD Marketing s Sensitrip Breakers • • • • True RMS sensing LSIG trip functions 200 to 1600A sensor ratings Long time adjustable from 20100% of rating • No rating plug required • Includes back protection of the electronic circuitry • Communication capability V:\Wendt DPD Marketing s Sensitrip Ammeter • • • • • • • V:\Wendt Direct Plug-in or Panel Mounting Trip Unit Powered with Battery Back-up 2 x 16 LCD Display Ammeter Display – Phase Currents – Average Current – Current Demand – Ground Current – Current Unbalance (%) Breaker Status – Normal – Impending Trip Time Stamped Trip Log (5 most recent) – Time & Date – Trip Cause: LT, ST, GF, SC Max Log – Max Phase Current – Max Average Current – Max Ground Current – Max Unbalance Current DPD Marketing s T Frame Breaker • • • • • • • V:\Wendt Highest amperage on the market Microprocessor RMS sensing 2000, 2500 & 3200A frames 100% rated available LSIG trip functions Cause of trip indication Field installable GF monitor or current module available DPD Marketing s IEC Circuit Breaker Family ON ON ON 45 3 6 7 2 LO HI 100A 125A 3VF2 & 1200A EF W L D W L D 25.4 (P) 124 73 L MF/NF D 76 159 102 229 406 152 16-100A 1-2-3 & 4700-1200A Poles V:\Wendt 15-125A 45 3 6 7 2 LO HI 250A W FFL ON 45 3 6 7 2 LO HI 45 3 6 7 2 LO HI 45 3 6 7 2 LO HI 400A D W 102 229 104 70-250A LJFD 45 3 6 7 2 LO HI 45 3 6 7 2 LO HI 45 3 6 7 2 LO HI 45 3 6 7 2 LO HI 600A W LF L D W 45 3 6 7 2 HI LO 45 3 6 7 2 HI LO 45 6 7 HI 800A 800 LMF L D W 178 279 104 178 279 104 178 406 152 300-400A 450-600A 600-800A 3 Poles DPD Marketing 3 2 LO s IEC Breaker Line • IEC 947-2 qualified • CE marked • NEMA interrupting ratings on the label • Common footprint w/ sentron • Full line of accessories • 40 or 50C Calibrated V:\Wendt DPD Marketing s IEC Interrupting Ratings IEC 947-2 Ue Icu EFC to NFC 220/240~ 65kA 35/40kA EFF to NFF 220/240~ 100kA 65kA 380/415~ 380/415~ V:\Wendt DPD Marketing NEMA Ics Voltage AIC 33kA 18/20kA 240Vac 480Vac 600Vac 65kA 35kA 22kA 50kA 33kA 240Vac 100kA 480Vac 65kA 600Vac 25kA s Additional Available Ratings • • • • V:\Wendt UL489/CSA/NOM IEC 947-2 CE Marine Supplement SB DPD Marketing •HID •SWD •HACR •UL1077 s The Sentron Advantage • • • • • Lower installed cost More application flexibility Easy to modify Complete product offering Siemens world wide presence • Single source supplier • Support tools V:\Wendt DPD Marketing s Lower Installed Cost • Thermal mag savings are available through 2000A • Interchangeable trip units reduce inventory and allow for retrofits • Sensitrip breakers are adjustable without the purchase of rating plugs • The Sensitrip Ammeter saves on CTs, wiring & installation • Max flex operators simplify and shorten installation • Field installable accessories in all frames allow for changes on the fly without waiting on the factory • Both UL & IEC lines are available with a common footprint and function V:\Wendt DPD Marketing s Application Flexibility • Fixed or interchangeable trip units available • Full line of field installable external accessories • Full line internal accessories and combinations (UVR, shunt trip, aux switch, bell alarm) • Full range of accessory coil voltages available to meet diverse applications – Shunt Trip – UVR 24 to 600Vac 120 to 600Vac 12 to 250Vdc 24 to 250Vdc • Sensitrip amperage rating is adjustable V:\Wendt DPD Marketing s Application Flexibility •External Accessories Walking Beam Interlock E Frame GF Module Locking Device Padlock Handle Blocking Device V:\Wendt Padlock attachment DPD Marketing s Application Flexibility •Rear Connecting Accessories Rear Connectors V:\Wendt Rear Plug Ins DPD Marketing s Application Flexibility •Operator Accessories Variable Depth Motor Operator Max flex V:\Wendt DPD Marketing s Easy to Modify •Interchangeable Trip Units in 250 to 2000A Frames INTERCHANGEABLE TRIP FIXED TRIP V:\Wendt DPD Marketing s Easy to Modify •Field Installable Accessories in ALL Frames Accessory Accessory mounted Accessory V:\Wendt Accessory mounted DPD Marketing s Complete Offering • • • • Size/Type Miniature Molded Case Insulated Case Power Circuit Breaker • • • • • Types Thermal Magnetic Electronic Magnetic only Molded Case Switch Current limiting Connection Means Bolt-on Plug-in Lug in / Lug out V:\Wendt DPD Marketing s Siemens World Wide Presence • Siemens is the 14th largest company in the world • Siemens is a knowledgeable resource for partners that want to grow in international markets. • Siemens is known and accepted world wide • Siemens has a growing specification presence through a dedicated consultant specialist organization • Siemens is the fastest growing US breaker manufacturer • Siemens has a world wide distribution network V:\Wendt DPD Marketing s Single Source Supplier Industrial Products PLC s General Electric s s Eaton / Cutler-Hammer Schneider / Square D Swboard / Pnlboard Busway LV Switchgear MV Switchgear Controls MCC Large Motor Small Motor DC Drives AC Drives PCS Siemens s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s Allen-Bradley / Reliance s s s s Toshiba s s s s s V:\Wendt MCCB s s s Voltage Regulator Power Breaker Residential Enc. Switch Xformer s s ABB Utility Products Construction Products s s s s s Represents major market presence DPD Marketing s s s Support Tools • • • • Breaker drawings on CAD Time current curve and series coordination software Specification Guide Individual breaker frame and instruction guides • Speedfax V:\Wendt DPD Marketing Sentron Thank You For Your Time s