Schneider Electric Pre Fabricated Modular Data

Center Overview & Discussion

Schneider Electric - Division - Name – Date

1

Schneider Electric is the Global Leader in

Pre Fabricated Modular Solutions

In January 2014 Schneider Electric acquired AST Modular the global leader in pre fabricated modular and containerized and modular Data Centers

 AST leads the pre-fabricated Modular Data Center Market (>20% market share)

 Over 600 Data Center projects successfully executed to date

 Projects deployed in over 50 countries

 First company to build a Tier 3 multi-Container Data Center

 Pioneered the manufacturing of high quality purpose built containerized data centers (2001)

 AST customers include IT leaders including IBM, HP, Dell, and Silicon Graphics

Schneider Electric - Division - Name – Date

2

Schneider Has Deep Experience in Delivering

Pre Fabricated Solutions

Schneider Electric - Division - Name – Date

3

Product Options

Schneider Electric - Division - Name – Date

4

Our Products Include a Wide Variety of Standard and Pre-fabricated IT Room Solutions

20 ’ & 40’ ISO

-All in one containers

-Multi container parks

25 ’ & 45’ NON ISO

-All in one modules

-Contiguous IT rooms

Secure IT rooms

-Indoor & Out Door

-Secure and any size

Schneider Electric - Division - Name – Date

5

3 Types of IT Modules for Different Applications

AST IT Modules

Compact ISO All-in-One

(20ft Enclosure,7Racks, UPS, PDU,

Overhead DX Cooling,

Standard ISO All-in-One

(40ft Enclosure, up to 19 racks,

PDU, overhead DX cooling

Ruggedized Solutions for

Industrial

(40ft Enclosure, up to 19 racks,

PDU, overhead DX cooling,

Ruggedized versions available

Multi-Bay IT Modules

(25ft – 40ft enclosure, Non-ISO design for more space. Cooling options - In-Row CW Perimeter CW,

Air Economizer Cooling, DCIM)

Modular Room

(20 x 45ft Enclosure,24 Racks, PDU,

3 Perimeter CRACs CW cooling,

DCIM)

Schneider Electric - Division - Name – Date

6

IT Module – Non ISO ”Wide Tall & Comfortable”

Overview

 Non-ISO design is wider, taller, deeper than container and engineered to provide a spacious, functional workspace for IT personnel

 Efficient, scalable design allows for custom, multi-module configurations from 20

– 240 racks

Multiple cooling solutions for chilled water, DX and air economization (In-row, Perimeter, End-of-

Row)

 Robust frame design simplifies installation and ganging together

 Best option for a complete configurable space.

Schneider Electric

Walk Through Our Demo Module Outside

- Division - Name – Date

7 7

Multi Module Designs

IT Rooms are joined together to form an “open white space”

IT room

Schneider Electric - Division - Name – Date

8

Base Designs – IT Modules

IT Room Modules

90kW All-in-One

(40ft Enclosure,10 Racks, UPS, PDU, In-

Row DX Cooling, DCIM)

110kW Single Module

(40ft Enclosure, 10 racks, PDU, In-Row

CW cooling, DCIM)

205kW Single

Module

(53ft Enclosure,14 racks, PDU, In-Row CW cooling, DCIM)

240kW Dual Module

(20 x 45ft Enclosure 22 Racks, PDU, In-

Row CW cooling, DCIM)

240kW Dual Module

(20 x 45ft Enclosure,24 Racks, PDU, 3

Perimeter CRACs CW cooling, DCIM)

Schneider Electric - Division - Name – Date

9

90 kW All-In-One Prefabricated Data Center Module

Data Sheet

Schneider Electric offers scalable, easy-to-deploy,

90 kW All in One Pre Fabricated Data Center (Non ISO)

Direct Expansion

Condenser Units

Schneider Electric - Division - Name – Date

Symmetra PX

100 kW UPS

9 Server Racks;

1 Networking

Rack

10

Input Power Voltage (Nominal) 480V AC; 3 Phase; 60 Hz

Max. Input Current 273A

Power Distribution

Total IT Load

90kW at N+1

(10 racks at 9 kW per Rack)

86 kW (Not Supported by UPS) Cooling Power Requirement

Non-Critical Power 9kW

Nominal Output Voltage to Rack 208V 3PH with Overload Protection

Main Distribution

Rack Distribution

AP8868 Metered, 10kW, 208V, 16A (20)

(36) C13 & (6) C19 - (2 per rack)

UPS and Battery System

UPS

Battery Type

Estimated Runtime

Symmetra PX 100kW, 208V at N+1

Double Conversion online

VRLA – Long Life Battery Modules (10)

5mins @ Full Load

Cooling

ACCD75204 Direct Expansion

Type,

Number of Units

Cooling Capacity

Internal Operating Humidity 10% - 95%

Internal Operating Temperature 60 ° F to 80° F (15.6° C to 26.7° C)

Racks

2 ACRD501 InRow Cooling Units

2 ACRP101 InRow Cooling Units

107 kW n+1

Rack Qty, Size and Type

Hot aisle

Cold aisle

Air blocking

Management System and Safety

9 - AR3300 - 42U x 600 mm (w) x 1200 mm (d)

1 - AR3350 - 42U x 750 mm (w) x 1200 mm (d)

36" w x 34' 0" l (922 mm x 10445 mm)

45" w x 34' 0" l (1152 mm x 10445 mm)

2 Interior Doors

StruxureWare Data Center Expert

Environmental Monitoring

Interface that monitors, manages and controls devices that provide power, cooling, security and environmental data.

Cooling Unit Temp Sensors: AP9335T (Qty 20);

Temp and Humidity Probes: AP9335TH (Qty 4);

Door Monitors NBE50302 (Qty 3);

Entrance/Staging

Lobby and

Electrical Room

Modular Power

Distribution

4 InRow

Cooling Units

FM-200 clean agent system with smoke/heat detection, auto/manual actuation, and audible/strobe alarms.

3 Exits

Fire Suppression,

Alarms, Controls

Fire Suppression and Detection

Emergency Exits

Physical

Length

Width

Height

Weight (Estimated)

Entrance Lobby for

Environmental Separation

Stacking

Environmental (external)

Operating Min/Max Temp.

Seismic and Wind Loading

Operating Altitude

12.3 m (40' 0")

3.5 m (11' 6")

3 m (10' 0")

Loaded: 47,122 lbs. (21,419 kg) (Typical)

1,103 lbs/m

2

(500 kg/m

2

)

4' 11" (1.5 m) w x 10' 9" (3.28 m) l

Optional

-20 ° to 50°C

Site Specific

0 – 1000m

NAM 90 kW All-in-One IT Module – PFMIED090D1N10A

90 kW All-In-One Prefabricated Data Center Module

Data Sheet

Schneider Electric offers scalable, easy-to-deploy,

Prefabricated Data Center Modules.

Direct Expansion

Condenser Units

10 Rack 90 kW N+1 “All in One” Wide Body”

Pre Fabricated Data Center

Symmetra PX

100 kW UPS

9 Server Racks;

1 Networking

Rack

Input Power Voltage (Nominal)

Max. Input Current

Power Distribution

480V AC; 3 Phase; 60 Hz

273A

Total IT Load

Cooling Power Requirement

90kW at N+1

(10 racks at 9 kW per Rack)

86 kW (Not Supported by UPS)

Non-Critical Power 9kW

Nominal Output Voltage to Rack 208V 3PH with Overload Protection

Main Distribution

Rack Distribution

AP8868 Metered, 10kW, 208V, 16A (20)

(36) C13 & (6) C19 - (2 per rack)

UPS and Battery System

UPS

Battery Type

Estimated Runtime

Cooling

Symmetra PX 100kW, 208V at N+1

Double Conversion online

VRLA

– Long Life Battery Modules (10)

5mins @ Full Load

ACCD75204 Direct Expansion

Type,

Number of Units

Cooling Capacity

Internal Operating Humidity 10% - 95%

Internal Operating Temperature 60 ° F to 80° F (15.6° C to 26.7° C)

Racks

2 ACRD501 InRow Cooling Units

2 ACRP101 InRow Cooling Units

107 kW n+1

Rack Qty, Size and Type

Hot aisle

Cold aisle

Air blocking

Management System and Safety

9 - AR3300 - 42U x 600 mm (w) x 1200 mm (d)

1 - AR3350 - 42U x 750 mm (w) x 1200 mm (d)

36" w x 34' 0" l (922 mm x 10445 mm)

45" w x 34' 0" l (1152 mm x 10445 mm)

2 Interior Doors

StruxureWare Data Center Expert

Environmental Monitoring

Interface that monitors, manages and controls devices that provide power, cooling, security and environmental data.

Cooling Unit Temp Sensors: AP9335T (Qty 20);

Temp and Humidity Probes: AP9335TH (Qty 4);

Door Monitors NBE50302 (Qty 3);

Entrance/Staging

Lobby and

Electrical Room

Modular Power

Distribution

4 InRow

Cooling Units

FM-200 clean agent system with smoke/heat detection, auto/manual actuation, and audible/strobe alarms.

3 Exits

Schneider Electric - Division - Name – Date

Fire Suppression,

Alarms, Controls

11

Fire Suppression and Detection

Emergency Exits

Physical

Length

Width

Height

Weight (Estimated)

Entrance Lobby for

Environmental Separation

Stacking

Environmental (external)

Operating Min/Max Temp.

Seismic and Wind Loading

Operating Altitude

12.3 m (40' 0")

3.5 m (11' 6")

3 m (10' 0")

Loaded: 47,122 lbs. (21,419 kg) (Typical)

1,103 lbs/m

2

(500 kg/m

2

)

4' 11" (1.5 m) w x 10' 9" (3.28 m) l

Optional

-20 ° to 50°C

Site Specific

0 – 1000m

NAM 90 kW All-in-One IT Module – PFMIED090D1N10A

IT Module Detail

2 bay, 24 Rack In-Row, 240kW shown

 240kW cooling capacity

 415V distribution @11kW per rack (2N)

 Power monitoring, management and controls

 Fire detection and

Staging Lobby and Electrical

Room suppression

 Staging lobby for outside isolation In-Row

Cooling

Units

Schneider Electric - Division - Name – Date

415 Modular

Power

Distribution

24 NetShelter Racks

Aisle Containment

12

25’ 5 rack 30 kW N+1 “All in One”

Schneider Electric - Division - Name – Date

13

20’ 3 rack 30 kW N+1 Data Comm Room

Schneider Electric - Division - Name – Date

14

Smart Shelter™ Prefab Modular Room Example

Phased Deployment View of (4)100 Rack IT Bays

Phase 3

Phase 4

Phase 1

100 Racks

Phase 2

100 Racks

Schneider Electric - Division - Name – Date

Gensets

Chillers

15

Smart Shelter™ Secure Prefab Modular Rooms

● Expandable rooms are secure, water, dust & fire proof thermally insulated modular IT rooms.

Rooms are built sized to any requirement.

● Installed Indoors or outdoor.

● Shelters can be disassembled & relocated.

● Rooms can expanded in a clean method.

● No construction construction dust or debris affecting expansion while operating.

● Visiting customers experience a “clean room” secure IT white space.

Schneider Electric - Division - Name – Date

16

IT Module – ISO Shipping Container

Schneider specific features

Echain cable management

Schneider Electric - Division - Name – Date

Seismic

Rack Mount

Sliding Rail

System

17

Base Designs - Power Modules

Power Modules

250kW

20ft Enclosure with UPS,

Switchgear, cooling, DCIM

500kW

40ft Enclosure with UPS,

Switchgear, cooling, DCIM

1.2 MW

Skid mounted, UPS,

Switchgear, DCIM

Schneider Electric - Division - Name – Date

18

Enclosed Power Modules

Air

Conditioners

Critical

Output

Switchboard

500kW

Symmetra

PX UPS

Fire Suppression

System

Schneider Electric - Division - Name – Date

Primary

Switchboard

500kW Module

 Symmetra N+1

UPS(250/500kW)

 5 min Runtime

 Switchboard w/ integrated

ATS

 Power monitoring, management and controls

 Environmental cooling

 Fire Suppression

 UL Listed

19

Skid Mounted Power Module

1.2 MW Skid Shown

 Allows for quick deployment within an existing building that is scalable for larger data centers.

 N+1 UPS MW UPS

 5 min Runtime

 Switchboard w/ integrated ATS

 Power monitoring, management and controls

Schneider Electric - Division - Name – Date

20

Cooling Modules

Cooling Modules

500kW Hydronics Modules

(Support 3-250kW Chillers)

1000kW Hydronics Modules

(Support 3-500kW Chillers)

Chiller Skids & Enclosures

Packaged Chiller, pump, and

Tank with connecting piping

250kW – 1.2 MW Packaged

Air Cooled Chillers -

Options with and without free cooling

Ecobreeze ISO frame

50kW increments up to 400kW of total cooling capacity (DCIM)

Schneider Electric - Division - Name – Date

21

AST Cooling Offer – CW & DX (Pending UL Certification)

Chilled Water Block Unit – CWB

Chilled water room cooling for prefabricated IT modules without raised floors

Capability

● Fits both ISO and Non-ISO prefab modules

● Designed to operate at higher water temperatures (15C)

● Top return with front supply air discharge

● Humidifier and electric reheat control options

Hot Corridor Heat Exchanger – HCX

Overhead cooling for prefabricated ISO IT modules

20 kW - 40 kW

● Chilled Water or Direct Expansion

● No floor space - located over the racks and hot aisle/corridor

Maintenance all done from hot aisle/corridor

● Requires chilled water plant or remote condensing unit

Schneider Electric - Division - Name – Date

22

AST Cooling Offer – Air Economizer

Natural Free Cooling Unit – NFC

Indirect Free Cooling for small or constrained data center spaces

50 kW

● Independent operating unit

● Heat Pipe heat exchanger isolating indoor and outdoor air

● Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling

Options

● Flexibility to have external heat rejection for mechanical cooling as required

- Chilled Water Plant or External Condensing Units

Direct Free Cooling Unit – DFC

Direct Free Cooling for small or constrained data center spaces

75 kW

● Uses air directly from outside for free cooling

● Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling

Options

● Flexibility to have external heat rejection for mechanical cooling as required

- Chilled Water Plant or External Condensing Units

Schneider Electric - Division - Name – Date

23

Global References

Education - Canada Utility - Australia

Healthcare - Italy

Schneider Electric - Division - Name – Date

Military - Europe

24

Global References

IT Software Company Government Customer – US

Global Bank – Denmark

Schneider Electric - Division - Name – Date

Cloud Service Provider –

Iceland

25

Mission-Critical Services

Consulting and Planning

Assessment, analysis, strategic planning and O&M program development services.

Design and Construction

Engineering, design-build and construction project management of facility expansions and new facility projects.

Commissioning

Data center and LEED commissioning from project inception to integrating testing.

Operations and Maintenance

Managed

Services and on-site Critical Facility

Management.

● Energy Management – Energy assessments, system optimization, and efficiency improvement projects.

● Alarm and Incident Management – 24x7 remote monitoring services through the

Schneider International Operations Center

(NOC).

Lifecycle Service Solutions

Schneider Electric - Division - Name – Date

26

Design-Build Benefits

2/2012

Schneider Design Build Outcomes

 Singular Accountability/Project Ownership

 Fully Integrated Project Delivery

 Speed to Market – Reduced Project Timelines

 Fewer Change Orders – Less Cost Overruns

 Continuous Project Budgeting and Scheduling

 Datacenter/Mission Critical Specific Team Skill Set

 Competitively Bid All Major Cost Items

Schneider Electric - Division - Name – Date

12/2013

27

28

Discussion, Questions and Answers

Thank you

Scott Fleming

Pre Fabricated Data Center Specialist scott.fleming1@schneider-electric.com

(925) 963 5468

IT Module – ISO Shipping Container

Overview

 ISO shipping container is defined to 8ft wide and lengths of 10ft, 20ft, 40ft, and 53ft in U.S.

 Containers are designed to be strong, rugged, environmentally sound and easily transportable anywhere in the world

 8ft width limits usable space for hot and cold aisles.

Height is also limited

 Schneider has unique solutions for slide racks and flexible cable trays to allow full access to front and rear of racks to overcome space limitations

 Overhead cooling units (DX and CW) are available to maximize rack space

Schneider Electric - Division - Name – Date

29 2

9

One-Size Does Not Fit All

200kW – 1.2MW

5 Racks – 200 Racks

Schneider Electric - Division - Name – Date

DX – Chilled Water – Direct Air – Indirect Air

30