: Latest Equipment Innovations for LCPD Colin Blackmore/Mark Davidson SICK (UK) Ltd AQE Conference March 2013 SICK process automation Process Emission Industry overview : SICK MAIHAK GmbH Power Waste Cement Pulp & paper Metal & steel Chemical Petrochem & refineries Oil & gas : SICK process automation : C.Blackmore/M.Davidson AQE 2013 2 SICK process automation Scopes Emission Process Tunnel Measuring devices and system solutions for continuous emission monitoring Analyser for a variety of process measurements Measuring devices for tunnel monitoring • Entire product range for all requirements • Compact transmitters with 1 to 2 measuring components • • In situ and extractive measurement technologies • High-performance analysers with up to 4 measuring components Rugged measuring devices with 1 to 3 measuring components • Measurement of air quality and visibility • Early fire detection • Solutions for all industries and legal regulations : SICK MAIHAK GmbH • Multi-component analysers > 4 measuring components : SICK process automation : C.Blackmore/M.Davidson AQE 2013 3 Equipment for LCPD : : Process gas analysers - DeNOx process monitoring and control equipment Continuous Emission Monitors - General Gas Analyser systems for Coal, Gas, Oil Power Stations - CCGT Plant and measurement of low levels of NOx - Mercury monitoring in Coal-fired Power Stations (separate Workshop presentation) : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 DeNOx Plant Air preheater Boiler EP FGD Gas preheater FGD plant Ammonia DeNOx Water reactor EP Limestone Slag : SICK MAIHAK GmbH Coal Air Ashes : SICK process automation gypsum : C.Blackmore/M.Davidson AQE 2013 Application SCR DeNOx Plant Why do we want to measure? With the help of a catalyst, NO and NH3 react to N2 and water: 4 NO + 4 NH3 + O2 4 N2 + 6 H2O NO measurement is important for the process control: a) raw gas before catalyst : to calculate the NH3 injection rate based on the “NO load” b) check catalyst efficiency and NH3-trim 1 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Application SCR DeNOx Plant Technical Data: Measuring Range: before SCR: up to 1,500ppm NO depending on burner technology after SCR : up to 100ppm NO depending on local regulation gas temperature: 340 ... 420°C high dust : typically 15g/m3 duct size: typically 5m (1.5 .... >6m) 1 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Extractive Technology Challenges : : Multiple Sample Probes with graded entry holes to try and balance the sample flow across large ducts and ensure accurate measurements Standard extractive CEM system with Filtration, Cooling, Sample Switching Problems - very high dust burden - high maintenance load on Sample Systems - unreliable systems : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 In-situ Technology Challenges : : : Cross duct not practical due to high Dust Burden, extinction of signal in large ducts High temperature application Sick Solution – extract sample and measure with small path length - Orientate probe so as to avoid large particles being captured - If 15m/sec flow achieved then remaining dust stays in suspension - Dust shows as general extinction, which can be calibrated out : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 GM32: The extended In-Situ solution : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 GM32 - optimized measuring value evaluation Absorption curves of SO2, NO, NO2 and NH3 : : : : Evaluation principle DOAS with sophisticated algorithms No influence of dust, droplets, humidity and other gases In-situ >>> delay free High and stable accuracy for high and low measuring ranges SO2 NO >>> DOAS Differential Optical Absorption Spectroscopy NH3 NO2 Wave length <-- 190 nm : SICK MAIHAK GmbH --> 400 nm : SICK process automation : C.Blackmore/M.Davidson AQE 2013 GM32 - Optical System - Control Cycle : Advantages: - Automatic self test Basic,Pro and upon request - Check of zero Basic,Pro and span Pro for each component. ▪ No test gases required. - Compliance to EN 14181, EN 15267-3 ▪ QAL3 zero & span values Pro ▪ TÜV approval Pro - Interval adjustable Basic,Pro : : Pro Version with filter wheel Basic version without ~ - no difference in quality of measurement : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 GM32 SCR De-NOx control : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 CCGT plants - CEMs : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Stack Power CO NOx,, O2, FLOW Generator Steam turbine Cooling air Steam Combustion air Gas turbine Generator Power Heat recovery steam generator Gas Flow Data Acquisition system Cem View or MEAC2000 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Application: CEMS for CCPP : Extractive Technology: In situ Technology Flow Gas FLOWSIC100 PowerCEMS100 CO, NOx, O2, option SO2, CO2 : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Minimum Requirements / Recommendations : Gas components -Nitrogen monoxide (NO) + Nitrogen dioxide (NO2) = “NOx as NO2” - IR not low enough ranges for NO - Carbon monoxide (CO) - Oxygen (O2), correction to reference conditions : Option - Sulfur dioxide (SO2), Carbon dioxide (CO2) : Flow measurement : Data acquisition system according to the EN or US EPA requirements : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Best Solution: PowerCEMS 100 MAC800 compact system PowerCEMS 100 GMS 830 and 831 analyzer modules Control unit BCU : SICK MAIHAK GmbH : SICK process automation sample gas cooler : C.Blackmore/M.Davidson AQE 2013 PowerCEMS 100 > Certified according to EN 15267-2 and EN 15267-3 to be used as AMS for CCPP > Compliant to EPA Part 60 and Part 75 CEMS requirements for gas fired power plants > Single central operating unit (BCU) for easy operation > No NOx converter for better measurement accuracy and lower cost of consumables Low level CO monitoring done by field proven UNOR best accuracy of any NDIR on the market. > > Compact, suitable for wall mounting Interface to DAS or DCS via Modbus or OPC or hard wire, adaptable to customer’s requirements. > : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Best Solution: Flowsic100 > Flue gas temperatures up to 450°C > High accuracy even at gas velocities near zero > Corrosion resistant Titanium transducers as standard > Representative measurement using cross-stack version : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Why is DEFOR better than Chemiluminescence ? > > Continuous individual measurement of up to 3 components NO, NO2 and SO2 No interference from background gases (H20 and CO2 show no absorption in the UV range) > Adjustment unit for calibration of DEFOR without using test gas > No Converter, No Ozone = less trouble : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 GMS800 Advantages : No need to use a NOx converter, change converter cartridges : User-friendly analyzer system : Designed for lower maintenance: simple single-point linearization, excellent thermal stabilit : With the UVRAS principle low ranges of NO, NO2, SO2 (0 - 25 ppm) can be accurately an individually measured. : Using the NDIR principle to measure CO in low ppm ranges (20 ppm) can be achieved. Ne Mounting of the NDIR bench on rubber supports reduces vibration sensitivity. : Using the paramagnetic measuring principle to analyze O2 : Latest cold dry CEMS analyzer technology UNOR & DEFOR with an excellent value for CC : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 Emission monitoring Application-specific fully configurable system Central control unit Connecting additional networks using standard interfaces Dust, volume flow (in situ) High-grade analyser modules and components All required gas components (extractive) (SO2, NO, NO2, NH3, HF, CO, CO2, CH4, HCl,N2O, H2O...) : SICK MAIHAK GmbH : SICK process automation : C.Blackmore/M.Davidson AQE 2013 28 : Thank you for your attention.