GeN2 Regen Duty Table Rated Speed (m/s) Load (Kg) 630 680 800 1000 1150 1275 1350 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Max. group control: G8C 1600 1/66 1800 2000 GeN2 Regen Space saving, energy saving, environmental friendly and excellent ride quality Gen2 Machine (MOR) Shenling Governor CSB NGSOK Regen Drive Controller 2/66 AES/AMS GeN2 Regen OTIS unique technology- Coated Steel Belt (CSB) 20% less in weight while 2-3 times life time Lubrication free Size: 30×3 & 60x3 Steel cords: 12 & 24 3/66 Cord diameter 1.67mm Technology from helicopter (Sikorsky) Breaking load: 32KN & 64KN GeN2 Regen CSB makes GeN2 Regen machine much smaller Roped Machine Gen2 Machine Diameter of sheave:100mm Diameter of sheave:115mm Groove:3/5 Groove:5 Brake voltage:24V Brake voltage:24V Insulation class: F Insulation class: F 4/66 GeN2 Regen CSB Monitor CSB monitor (RBI) – Resistance Based Inspection (RBI) for CSB – Dynamic inspection of CSB status – LED indication – Elevator level at nearest floor when failure inspected – REM interface – A component, not a tool 5/66 GeN2 Regen OTIS GECB Controller board Motorola 32 bit CPU with 1M Flash memory. Rear time failure clinic automatically CAN BUS 2.0 communication CE Comply ESD to avoid jobsite damage Up to100 floors and 4m/s ESD: Electro-Static discharge 6/66 GeN2 Regen ACD2 MRL Controller and Drive OTIS energy regenerative drive CAN-bus communication Mini E&I Panel Drive E&I Panel 210W x 540H x 90D Controller 7/66 320W x1300H x 160D GeN2 Regen Regen Principle Regenerative system Energy saving Up to + OTIS Regenerative Drive OTIS Gen2 Machine 8/66 GeN2 Regen NGSOK Door operator Key parameters: Center Opening 700 800 900 1000 1100 1200 Open Time(s) 2.2 2.3 2.5 2.9 3.3 3.7 Close Time(s) 2.4 2.5 2.7 3.1 3.5 3.9 • PM motor, energy saving Re-open Distance(mm) 100 • VVVF controller Open/Close noise(dBA) 52 (Peak) • Motor drive directly, no gearbox Re-open noise(dBA) 55 (Peak) • Disc motor, space saving • Easier for installation – Side opening is availble OP=900~1300 – Standard opening height:2100/2000 • Max. moving mass: 200kg • Motor IP: 44 9/66 For Gen2 Regen and also for all other passenger elevators Safety Components GeN2 Regen E3 Qualified Safety Gear Speed governor – Otis US design qualification – Otis US MFG process control – Otis US change control – Reliable – Durable – Traceability Oil buffer Comparison Component OTIS E3 Requirements Safety Gear 25 freefall and runaway test Speed Governor 25 Continuous tripping Buffer 100 strike test EN81-1 Requirements 4 freefall test 20 Continuous tripping 10/66 6 strike test GeN2 Regen Excellent Performance Data Gen2 Regen Traditional lift (Belted, gearless) (Roped geared) X- Vibration A95 (mg) ≤9 ≤ 11 Y- Vibration A95 (mg) ≤9 ≤ 11 Z- Vibration A95 (mg) ≤ 11 ≤ 14 Speed Tolerance (%) (@+10%VRate, +1%fRate, Tmax 40℃) +3 +5 Maximum Acceleration( m/s2) (@ start and stop) 1.2 1.2 Maximum Jerk ( m/s3) (@ running) 1.0 1.0 Noise (dB) (@ Machine room) ≤ 72 ≤ 75 Noise (dB) (@ In car, w/o fan, running ) ≤ 53 ≤ 53 Typical: ±3 Max. : ±5 ±5 System performance Level accuracy (mm) (@+7%VRate, +1%fRate, Tmax 40℃) 11/66