REGEN Energy Swarm Energy Management™ www.REGENenergy.com WHAT IS SWARM LOGIC? Traditional Method Swarm Logic Method Auto DR Event EASILY DEPLOYED USING YOUR EXISTING HVAC SERVICE TEAM, WITHOUT IT MODIFICATIONS A Gateway provides Internet communication without the need to access the site’s network. Power readings and decisions are uploaded every 5 minutes. A ZigBee network allows Controllers to “talk to each other” in a swarm. HVAC HVAC LIGHTING Swarm Energy Cloud Swarm Energy Management Web 2.0 APIs Controllers are monitored and adjusted via a web based portal. HVAC Controllers measure power readings every 30 seconds. PUMPS ELECTRIC HEATING Each Controller makes a decision every 10 minutes. Customer Portal SIMPLE OPENADR COMMUNICATIONS Event Info communicated via web between the DRAS Server and REGEN’s Standalone DR Client Southern California Edison DRAS Server Event Info automatically sent to customer site. Two-way communication provides real-time load drop verification. REGEN Standalone DR Client AutoDR Event Signal Automatic Schedule Population of Upcoming DR Events REGEN Energy 24x7 Support Center Customer Site RTU OpenADR Landscape EASY DEMAND RESPONSE WITH MINIMAL IMPACT ON COMFORT T-stat rebound 1000 900 800 Smoother exit 700 KW 600 500 Swarm Energy Management’s Benefits: 400 300 200 Power 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 60 55 Immediate increase RH 50 45 40 35 Interior Temp./Humidity Gradual effect 30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Schedules DR events automatically using AutoDR Maintains comfort better than t-stat setback Provides fine-grained, predictable DR curtailment Reduces rebound during/after DR events Thermostat Setback Swarm Energy Management DR DECENTRALIZED CONTROL PROVIDES EASY, SIMPLE ACCESS TO MULTIPLE USERS Web-based Portal • No software installation required Secure Control • Site-level permissions • Allow view only or manager roles Scheduling • Ability to group loads per zone • Schedule load duty cycles for recurring or one-time events Alerts • Receive email when warning conditions exist • Ensures sufficient Demand Response curtailment achieved Analytics • View real-time or historical load profiles • Can export as spreadsheets SWARM ENERGY MANAGEMENT EVEN PROVIDES BENEFITS TO BAS-EQUIPPED SITES Monitoring Benefits • Internet-based remote monitoring & control aids recommissioning efforts • Real-time & historical sub-metering per load, site, or portfolio of sites Demand Management Benefits • Proven occupant comfort benefits vs. load-limiting strategies • Seasonal benefits well beyond summer peaks alone Demand Response Benefits • Simple AutoDR participation, automated event scheduling • Superior occupant comfort compared to temperature setback strategies SWARM ENERGY MANAGEMENT BENEFITS Sample Building: 20 RTUs, avg. 7.5+ tons & 180kW 700 S. Telshor Las Cruces, NM 88011 Reduces Peak Demand while Maintaining Comfort (~15-25% = 25-40kW) Provides Intelligent Demand Response, incl. AutoDR (adtl. ~20-50kW) Minimizes Off-Hours Consumption (~10-30% = 35,000-100,000 kWH/year) Remote Monitoring and Scheduling with Ability to Lock Out Thermostats Rapid ROI for a Building Enhancement CASE STUDY: ALLEN THEATRES Problem: - Employees playing with thermostats, overriding set schedules - Very high energy costs Solution: Installed REGEN’s Swarm Energy Management at 11 different theaters in 2010 and 2011 2012 RESULTS Total Peak Demand Reduction (kW) Average kW Reduction (%) Total Consumption Reduction (kWh) $ Savings 572 16% 446,185 $ 34,227 Since implementing Swarm Energy Management, Allen Theatres has saved over $85,000 REGEN Small Site Case Study Site Name # of AC Units with controllers ACE Hardware 4 Fitness Center 14 Fitness Center #2 14 Chevrolet Dealership 11 Office Building 9 Customer Comfort Responses to Baseline Day: How comfortable are you with the temperature today at work? Normal Operation Business ACE Hardware Fitness Center Fitness Center #2 Chevrolet Dealership Office Building Total 1) Definitely too cold 3) Just right / 4) A bit 5) Definitely or 2) A bit chilly OK warm too hot Total Count % Count % Count % Count % Count % 0 1 0 0 1 0% 9% 0% 0% 9% 0 1 0 0 1 0% 9% 0% 0% 9% 0 2 1 0 3 27% 0% 18% 9% 5% 0 1 0 0 1 27% 0% 9% 0% 0% 0 5 1 0 6 37% 0% 45% 9% 0% 0 0% 10 82% 2 18% 0 0% 12 100% Customer Comfort Responses to DM event: How comfortable were you with the temperature between 4-7 PM? Demand Management Business ACE Hardware Fitness Center Fitness Center #2 Chevrolet Dealership Office Building Total 1) Definitely too cold 3) Just right / 4) A bit 5) Definitely or 2) A bit chilly OK warm too hot Total Count % Count % Count % Count % Count % 0 1 0 0 1 0% 6% 0% 0% 6% 0 1 0 0 1 0% 6% 0% 0% 6% 0 5 1 0 6 35% 0% 29% 6% 0% 0 4 2 0 6 35% 0% 24% 6% 0% 0 3 0 0 3 18% 0% 18% 0% 0% 0 0% 14 82% 3 18% 0 0% 17 100% Customer Comfort Responses to DR1 event: How comfortable were you with the temperature between 4-7 PM? Demand Response 1) Definitely too cold 4) A bit 5) Definitely 10% or 2) A bit chilly 3) Just right / OK warm too hot Total Business Count % Count % Count % Count % Count % ACE Hardware 0 2 0 0 2 15% 0% 15% 0% 0% Fitness Center 0 1 0 0 1 0% 8% 0% 0% 8% Fitness Center #2 0 2 0 0 2 15% 0% 15% 0% 0% Chevrolet Dealership 0 3 1 0 4 31% 0% 23% 8% 0% Office Building 0 3 1 0 4 31% 0% 23% 8% 0% Total 0 0% 11 85% 2 15% 0 0% 13 100% Customer Comfort Responses to DR2 event: How comfortable were you with the temperature between 4-7 PM? Demand Response 1) Definitely too cold 4) A bit 5) Definitely 20% or 2) A bit chilly 3) Just right / OK warm too hot Total Business Count % Count % Count % Count % Count % ACE Hardware 0 2 1 0 3 13% 0% 8% 4% 0% Fitness Center 0 1 0 0 1 0% 4% 0% 0% 4% Fitness Center #2 0 5 1 0 6 25% 0% 21% 4% 0% Chevrolet Dealership 0 5 0 0 5 21% 0% 21% 6% 0% Office Building 0 5 4 0 9 38% 0% 21% 17% 0% Total 0 0% 18 75% 3 25% 0 0% 24 100% Additional Savings kWh savings realized by utilizing REGEN’s scheduling functionality Site ACE Hardware Fitness Center Fitness Center #2 Chevrolet Dealership Office Building Annual Energy Savings, kWh 19,310 5,961 14,222 9,608 1,354 Swarm Energy Management™ Energy Management Naturally™ REGEN Energy Contact: James McPhail james@REGENenergy.com 909.809.7635 www.REGENenergy.com