ANSC 7003

advertisement
SABOT
Standardized Auxiliary Boat
Operations Training
Ninth District - Eastern Region
COMO. Lew Wargo, Sr.
DSO-OP/CQEC
12 April 2014
ANSC 7003
SABOT
Vessel Facility
Inspection and Offer
For Use Form
ANSC 7003
OFFER FOR
USE FORM
• Instructors: Pass out blank ANSC-7003 forms
for the students to follow along on.
OFFER FOR
USE FORM
• In the top right corner check as appropriate
what this form is for:
– Initial (new) Report
– Re-inspection (re-offer)
– Change
SECTION I
OWNER DATA
(completed by owner)
Owner’s (and co-owner’s) member ID number
and name
Check type of ownership: (Sole, Aux, Unit,
Gov’t, Multiple, Corporate)
Registration or Documentation Number (No
spaces in the registration number.)
Hull Identification Number
SECTION II
FACILITY DATA
(completed by owner)
• Facility’s Name:.
• Facility Number: Six digit radio call sign (Leave
blank if unassigned)
• Vessel Location: Where vessel is moored or kept
if trailered.
• Zip Code: Of location above
• Latitude and Longitude: Of location above
SECTION II
FACILITY DATA
(completed by owner)
• MANUFACTURE: Enter name vessel’s
manufacture
• MODEL: Enter manufacture’s model for vessel
• Year: Enter year of manufacture.
• Type of Vessel: Enter vessel type from list of
vessel codes on page 5 of ANSC 7003 form
• Length: Enter overall vessel length in feet and
inches
• Beam: Enter vessel’s beam in feet and inches
SECTION II
FACILITY DATA
(completed by owner)
• Draft: Enter the draft of the vessel in feet and
inches
• No. of Bunks: Enter the sleeping capacity
• Water Capacity: Enter the water tank capacity. If
not equipped, enter “N/A”
• Type of Power: Enter the type of power, use
code from page 5 of ANSC 7003 instructions
• No. of Engines: Enter the number of main
propulsion engines
SECTION II
FACILITY DATA
(completed by owner)
• HP Each Engine: Enter the HP for each engine
• Type of Fuel: Enter the type of fuel, GAS for
gasoline or DISL for diesel
• Fuel Capacity: Enter total fuel capacity in US
gallons.
• Previous Boat No: Only replacing a facility.
• Cell Phone: Enter the 10 digit cell phone number
if normally carried onboard.
• DSC No: If equipped, enter your DSC number.
SECTION II
FACILITY DATA
(completed by owner)
• Check appropriate box for: (NIGHT OPS), (IS
BOAT TRAILERABLE), (INSTALLED RANGE),
(INSTALLED SPACE HEATER)
• Engine Manufacture: Enter engine manufacture
from list of codes on page 5 of the ANSC 7003
• Model Number: Enter each engine’s model
number
• Year: Enter each engine’s year of manufacture
• Serial Number: Enter each engine’s serial number
SECTION II
FACILITY DATA
(completed by owner)
• K. W. Capacity: Enter generator capacity if
installed.
• Check the applicable FACILITY AVAILABILITY
box
• Fuel Consumption: Enter the fuel
consumption per hour and the speed in knots
for economical, cruising, and maximum
speeds. (Normally the economical will have
the lowest and maximum the highest)
SECTION II
FACILITY DATA
(completed by owner)
(NOTE:) Any gasoline engine running at full power
will burn approximately 10% of its horsepower as
gallons per hour (GPH). This is a “Rule of Thumb”
that is not exact, but, fairly close.
• Check box if installed Compass, RDF, etc.
SECTION II
FACILITY DATA
(completed by owner)
• Other Special Equip: List all other equipment carried
onboard. Attach a separate sheet if necessary. (Ex:
EPIRB, strobe lights, rafts, camera, CB radio, lines,
fenders, etc.) (Be sure to include all items from
inspection list on back side of ANSC 7003 “Offer-ForUse-Form” ).
• Also, enter here or in the bottom margin the
Facilities Limitations. (See the next slides)
SECTION II
FACILITY DATA
(completed by owner)
• Facility Limitations; Maximum seas (in feet) in which
the facility can operate Safely and Effectively!
• The following guidelines are published in the
Ninth District Instruction: M16100.1(series)
Appendix 5, Annex “J”
CG d9
AUXILIARY
LIMITATIONS
AUX-FAC
OFF SHORE SEAS WIND
PWC
<1 NM
<3’
<25k
14’ – 19’
<3 NM
<2’
<20k
20’ – 25’
<5NM
<3’
<20k
26’ – 40’
<5NM
<4’
<25k
40’ – 65’
<10NM
<6’
<25k
65’ +
<30NM
<8’
<30K
CG owned/
AUX RB-HS
<10NM
<4’
<25K
TOWING
NONE
<2 gr. tons
<5 gr. tons
<5 gr. tons
<10 gr. tons
<25 gr. tons
<10 gr. tons
SECTION II
FACILITY DATA
(completed by owner)
• Value-Hull: Enter fair market value of hull
• Value-Machinery: Enter fair market value of
engines
• Value-Electronics: Enter fair market value of
electronics onboard.
• Value-Other Equip: Enter fair market value of all
other equipment onboard.
• Total Value of Vessel: This should be sum of
above
SECTION III
OWNERS STATEMENT
(completed by owner)
• Owner checks box that vessel is offered for use as
stipulated .
• Owner should check the appropriate box
certifying that all statements are true and
correct.
• Enter owner’s unit ID number
• Owner signs and dates form
• If trailered, owner initials as agreement that the
towing vehicle and trailer are in compliance with
all state motor vehicle laws and the trailer is large
enough to carry the load.
SECTION IV
USCGAUX’s VE
STATEMENT
• TO BE COMPLETED BY VESSEL EXAMINER
SECTION V
CG ACCEPTANCE
(completed by
DIRAUX OR OTO)
• Completed by DIRAUX or OTO
SECTION VI
REQUIREMENTS FOR
AN AUXILIARY FACILITY
(completed by USCGAUX VE)
• Where quantities are required (PFDs) enter the
number onboard.
• Also, it would be a good idea to provide the
quantity of such items as:
– Boat hooks
– Fenders
– Fire Extinguishers
– Line
SECTION VII
OPERATION BY A
NON-OWNER
(completed by owner)
• List all (if any) other member may operate the
facility as the coxswain. If additional space is
required an additional sheet may be used. If
no other coxswain, check box provided. If
owner is not on board, each coxswain must be
specified.
• Owner Must Initial Lower Left
Download