T775 Series 2000 Stand-Alone Controller New Product Introduction Sales Presentation February 5, 2007 T775 Series 2000 • T775 Series 2000 replaces - T775 Series 1000 models - H775 Humidity Controllers • Release date set for second quarter • 38 existing models replaced by 14 new T775 models T775 Series 2000 2 Informative Home Display Relay Status Sensor Temperature Modulating Output Status Digital Input Status Easy to Use Keypad 3 Home Screens Provide Useful Info • See sensor, modulating output, and relay configuration information • See senor, modulating output, and relay status information • Use the left and right arrow buttons to scroll through status screens for all defined outputs, modulating, and relays 4 Easy-to-Use Graphical Interface • Menu driven programming • As easy to use as your cell phone • Program with clear, plain language prompts Easy programming saves installation time 5 Time Clock Scheduler Built-In • For Setback or Disable Output Option • Save energy during unoccupied times • Gives you more control over your equipment without needing to purchase an additional time clock • All T775 models include the scheduler Energy saving feature 6 Up to 2 Independent Modulating Outputs • Configure each output individually for - 0-10 Vdc, - 2-10 Vdc, - 4-20 mA, or - Series 90 • Versatility saves time in selecting the right control for the job One model handles many field requirements 7 NEMA 4x Enclosure Option • Protected from water and corrosion • Install in animal confinement areas, washdown areas, swimming pools, and similar locations • Fours models with NEMA 4x enclosures; all others have NEMA 1 - T775B2016 - T775B2024 - T775M2022 - T775M2014 The right control for harsh locations 8 Modulating High or Low Limit Control • Equipment protection • If you need to protect a coil from freezing, or your equipment from overheating • Gives you the ability to adjust your control temperature at sensor A to protect equipment at sensor B • Three models offer hi/low limit control feature: - T775R2043 - T775M2048 - T775M2030 Consistent control while protecting your equipment 9 Extended Temperature Range • Setpoint temperature range of -40°F to 248°F • Gives you the ability to control a wider range of temperatures with a single device • One device covers it all 10 Configure Integral and Derivative Times • For applications where pinpoint control is required • Option is standard on every device • PI control on modulating outputs is setup by default to behave just like the previous T775 Series 1000, but now you can adjust reaction times and behavior as you like it, giving you more control. 11 Digital Input Option • Connect an external time clock or any external switch to the digital input • Allows you to either disable all outputs or trigger them for a programmed setback temperature • Standard on all models 12 Reset Models with Simplified Setup • Vastly simplified reset programming • Simply enter the high and low control temperatures and the corresponding high and low outdoor temperatures • Reset saves energy - as the outside temp gets colder you can reset the setpoint temperature to save energy Faster setup & energy savings for customers 13 Reset Set-Up 14 Power Supply • All T775s can be powered with low or line voltage - 24 Vac - 120/240 Vac • No need to add a separate transformer No guessing which control you’ll need 15 Configure Minimum Off Time • Protect equipment by setting a minimum off time if needed • Reduces the need for a separate time delay device to protect equipment • Set once for all relays • Option available on all models with relay outputs. Set once for all relays 16 Sensor Calibration • Calibrate input sensors +/-10°F - T775U calibrations values are +/-10% of the user defined input range • Use to compensate for resistance drops in wire leads • Use to offset the input temperature for sensor location or for any other reason Flexible and accurate control 17 Name Each Sensor • Select from a list of descriptive labels for each sensor • Label will always include A, B, and C designators for Sensor A, Sensor B, and Sensor C • Sensor labels displayed on the Home screen 18 Sensor Names Appear on Home Screen Sensor Names Always Displayed on the Home Screen 19 Display Relay Runtime • Quickly and easily check to see how many hours a stage has been running • Reset to zero at any time • Available on all models Runtime Displayed for Each Relay 20 Locking Keypad • Keep configuration secure from unauthorized changes • Easy to lock/unlock but not obvious how to unlock unless you know the system Lock Icon Indicates Keypad is Locked 21 Fewer Models • 14 Series 2000 T775 models replace 38 Series 1000 T775 models • Reduce inventory • Eliminate the headache of choosing the right controller Reduced inventory keeps the money in your pocket 22 Standard Models • Use in standard applications • Minimal setup and configuration required • All models ship with one temperature sensor; all except single relay model can accept two sensor inputs. • Floating output option now available! Product Number Description Replaces Relay Outputs Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 T775A1001/U 1 SPDT – 2 SPDT – # Sensors Included 1 1 1 2 1 T775A2009 Standard T775B2016 Standard-NEMA 4X T775B2032 Standard T775A1019/U T775B1000/U 2 SPDT – 1 2 1 T775B2024 Standard-NEMA 4X T775C1009/U T775D1008/U 4 SPDT – 2 2 1 T775B2040 Standard T775A1027/U T775A1035/U T775B1018/U T775B1026/U T775B1042/B T775B1042/U 4 SPDT – 2 2 1 – * One floating output eliminates the two relay outputs. 23 Sensor Inputs Floating Output* Modulating Models • Use in modulating applications, with the option for relay outputs as well. • Easily define analog output configuration through programming • All models ship with one temperature sensor Product Number Description Replaces Relay Outputs Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 Floatin g Output* Sensor Inputs # Sensors Included T775M2006 Modulating – None 2 – 2 1 T775M2022 Modulating-NEMA 4X – 2 SPDT 2 – 2 1 T775M2048 Modulating T775E1015/U T775E1023/U T775E1056/U T775E1064/U T775E1098/U 2 SPDT 2 – 2 1 T775M2014 Modulating-NEMA 4X T775G1005/U T775G1013/U T775G1021/U T775G1039/B 4 SPDT 2 – 2 1 T775M2030 Modulating T775E1114/U T775F1022/U T775F1055/U T775F1089/U 4 SPDT 2 – 2 1 * One floating output eliminates the two relay outputs. 24 Reset Models • Use in applications requiring reset • All models ship with two temperature sensors Product Number Description Replaces Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 Floating Output* Sensor Inputs # Sensors Included T775R2035 Reset option T775J1001/U T775J1076/U 2 SPDT – 1 2 2 T775R2043 Reset option T775J1019/U T775J1027/U T775J1035/U None 2 – 2 2 T775R2027 Reset option T775J1043/U T775J1050/U T775J1068/U 2 SPDT 2 – 2 2 T775R2001 Reset option – 4 SPDT – 2 2 2 T775R2019 Reset option – 4 SPDT 2 – 2 2 * One floating output eliminates the two relay outputs. 25 Relay Outputs Boiler with Reset Model • Handle multi-stage boiler applications with this single controller. • 1 dedicated pump output • Staging for up to 12 relays • 1 digital output alarm • Pump exercise, pump pre-purge and post-purge, warm weather shut-down. • Displayed run time • Ships with three temperature sensors Product Number 26 Description Replaces Relay Outputs Analog Outputs 4-20mA, 0-10Vdc, 210Vdc, & Series 90 Sensor Inputs Available # Sensors Included Output Reset T775P2003 Special Boiler with Reset – 4 SPDT – 3 3 X T775S2008 Four relay expansion module – add one or two for a total of 8 or 12 relays. – 4 SPDT – – – – Stage Sequencer with Reset Model • Four stages or add up to two optional 4-stage expansion relay modules for 8, or 12 stage operation • Flexible setup allows you to configure these stages any way you like for heating, cooling or divide up the stages as you like for both heating and cooling • Operating up to 12 stages, these can control multiple low-mass boilers, chillers, and/or electric heat from a single control • Expandable to 12 relays with the T775s 4-Relay Expansion Module • Ships with one temperature sensor Description Replaces Relay Outputs Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 T775L2007 Stage Sequencer with Reset Option – 4 SPDT – 2 1 X T775S2008 Four relay expansion module – add one or two for a total of 8 or 12 relays. – 4 SPDT – – – – Product Number 27 Sensor Inputs Available # Sensors Included Output Reset Universal Model – for pressure, humidity, etc. • Easy setup for configuring control of pressure, humidity, temperature, or any medium with a 0-10Vdc or 4-20mA sensor input. • Select from a variety of pressure, humidity, etc. sensors for the desired application. • Control humidity with % RH displayed, or control pressure with in. w.c., psi, Pa, or kPa displayed. • Outputs include 2 modulating and two relay outputs that can each have its own setpoint. • Ability to reset the output based on outdoor temperature, handy when you need to reduce window condensation when setting humidity levels • Complete versatility in a single control allows you the freedom to do what the job requires Product Number T775U2006 28 Description Universal - Humidity, Pressure, etc. Replaces H775A1006/U H775A1022/U H775A1048/U H775A1063/U H775B1005/U H775C1004/U H775D1003/U H775E1002/U Relay Outputs Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 Sensor Inputs Availab le # Sensors Included Output Reset 2 SPDT 2 2 0 X T775 Legacy Product Comparison Feature/Function 29 T775 Series 1000 T775 Series 2000 Relays 1 to 4 SPDT 1 to 12 SPDT (with T775S) Relay Contact Rating 9.8A full load at 120Vac Same Power Supply 24, 120, 240 VAC Same Modulating Output 1 modulating, up to 3 SPDT relays 2 modulating, up to 4 SPDT relays. Scheduler No Standard on all models. Provides one setback period per day, configurable for each day of the week. Temp Sensor PT3000 PT1000 IEC 751 Watertight Temp Sensor With NEMA 4X models Same NEMA 4X enclosure Optional up to 4 relays Same Approvals UL UL, CE, C-Tick Ambient temp range -40 to 140F same Modulating outputs: 0 - 10 Vdc, 2 - 10 Vdc, 4 – 20 mA, Series 90 Floating Requires a separate model for each type supported Models with mod output support all types (except floating option which is offered on the relay output models). Supports 0 - 10 Vdc output No Yes Supports floating output No Yes Temperature Setpoint Range -40 to 220F -40 to 248F Differential/Throttling range 1 to 35F 1 to 150F Integral Action Fixed Configurable (settable integral time) T775 Legacy Product Comparison (cont) Feature/Function 30 T775 Series 1000 T775 Series 2000 Digital Input Disable all outputs Options: 1) Disable all inputs 2) Alternate setpoints for all outputs Reset Yes Yes - with simplified configuration Reset optional All outputs or none. Configurable for each output Reset Set up DIP switches LCD user interface Irreversible setpoint high limit to meet some codes No Optional Engineering Units Standard Models F or C Same Engineering Units Universal Model NA F, C, in wc, psi, %, kPa, Pa Relay Minimum Off Time No Configurable Power up action 300 second countdown before control enabled Minimum off activated at powerup (yes/no choice for each relay) Sensor Calibration No Yes Output Sequencing Option No Yes – single setpoint drives multiple relays. High or Low Modulating Limit Control No Yes Humidity Control H775 up to 4 relays, 2 sensors required for mod out Universal Model supports relay or modulating RH control, with Temp Reset option Boiler Special Model No Yes- single setpoint drives multiple relays, Alarm Output, 3 sensor inputs available (supply, return, outside). Johnson Controls–A350 Strengths Challenges • • • • • Modular design Easy to install Simple to use Low cost , simple single relay model (a large share of the business) • Customer loyalty 31 • • • Multiple parts to buy for each installation Cost goes up quickly when modules are added Expensive when using multiple relays with an LCD display Feature set can’t compare with T775, see next slide Competitive Comparison–Johnson Controls Feature Honeywell Johnson Controls 7 day, 2 events per day no 0-10 Vdc, 4-20 Vdc, 4-20 mA, Series 90 & Floating 0-10 Vdc and 4-20 mA Built-in Display Yes No High/Low Mod Limit Control Yes No -40°F to 248°F All models, with Celsius too. Either -30F to 130F or 90F to 250F 1-150°F 2-30°F Digital input for setback or disable Yes No Sensor Calibration Yes No Adjustable minimum off time Yes No Integral voltage options Yes No Nema 4x Models Yes No Irreversible high setpoint limit Yes No Timeclock with setback Modulating Outputs Wide Setpoint Range Throttling Adjustment Range 32 Tekmar–264 and others 33 Strengths Challenges • • • • • Can be complicated to set up • Fixed segment display cryptic to decipher without instructions • High cost products Wide Range of products Application knowledge Excellent Web site Support consulting engineers www.honeywell.com 34