Changing Attitudes to Health
Bodystat 1500
®
BODY COMPOSITION
ANALYSIS
Fat Weight -NOT total weight- determines health risk
BIA Current Flow
Bio-Electrical Impedance Analysis
(BIA)
•Safe, battery generated signal is passed through
the WHOLE body and measures the resistance to
the flow of the current.
•Lean conducts electricity far better than the
body’s fat compartment.
•The Impedance value together with the details of
Age, Gender, Height and Weight are used by the
regression equations.
DISPLAY RESULTS
Actual
•FAT
22.6 %
•FAT
13.7 kg
•LEAN
46.9 kg
•DRY LEAN
12.8 kg
•TOTAL
60.6 kg
•WATER
56.3 %
•WATER
34.1 Lt
•BMI - BODY MASS INDEX
•BASAL METABOLIC RATE
•IMPEDANCE
Normal Range
20 - 26 %
12 - 16 kg
45 - 48 kg
59 - 62 kg
50 - 60 %
30 - 37 Lt
PRE-TEST PROTOCOLS
•No eating or drinking 4 to 5 hours prior to the test;
•No exercise 12 hours prior to the test;
•No alcohol or caffeine consumption 24 hours prior
to the test;
•Ensure that the subject is lying down for at least
3/4 minutes with arms and legs spread slightly;
•Do not re-use or cut the electrodes.
FEATURES
•WHOLE Body Analysis
•Safe, Non-Invasive
•Easy to Use
•3 Second Test Results
•Battery Operated
•2-Line LCD Display
•Lightweight & Portable
•Built-In Calibration
ADDITIONAL FEATURES
•Automatic 100-Test Counter
•Subject Data Recall
•Actual Results & Recommended Ranges
•Low Battery Alarm System
•12 Month Parts & Labour Warranty
•Accepts Metric or Imperial Units
•Quality Approved: CE, FDA, & Medical
Devices Directive – CE0120 Registration
•Automatically Supplied with 5 Languages
KEY BENEFITS
•Essential Motivational Tool
•Perfect For Weight Management Programs
•User Friendly Device ideal for Clinical Trials
•Scientifically Validated
•Save Data into dBase/Excel Files
•Direct Printer Option
Available Options
Bodystat for Windows™ Software Programs
Body Manager
•Summary Body Composition Analysis
•Trend Report
•Weight & Activity Manager
•Cardiac Risk Analysis
•Other Features Include:•Alternative Metabolic Formulae
•Predictive Equations: Geriatric, Competitive
Athlete & Children
•User Selectable Optimal Ranges
Potential Users

Fitness professionals in fitness centre, sports &
leisure centres, gymnasiums and weight-loss clinics

Corporate Health & Fitness

Athletic & Sports Teams

Hospitals, Physicians, Nurses, Dietitians and Health
Specialists

Medical Researchers & Sports Scientists
Bodystat1500 in Doctor’s
Surgery
Spirometry: Normal and
COPD
0
FEV1
N o rm a l
COPD
1
L ite r
2
FVC
F E V 1/ F V C
4 .1 5 0
5 .2 0 0
80 %
2 .3 5 0
3 .9 0 0
60 %
FEV1
3
COPD
4
FVC
FEV1
N o rm a l
5
1
2
3
FVC
4
5
6
Seconds
QuadScan 4000
Multi-Frequency Unit
Body Composition & Hydration/Nutrition
QuadScan Software
Line Graph
Why Multi-Frequency?
At 5 kHz current unable to penetrate the cell
membrane wall = ECW
At 200 kHz current fully able to penetrate the cell
walls = TBW
ICW = TBW – ECW
ICW = 70% of Body Cell Mass
(the metabolically active tissue)
Multi-Frequency BIA
Loss of BCM (5% loss within 6
months) is a significant
contributor to the morbidity and
mortality associated with wasting
diseases.
BUT
BCM not easy to measure
Hence
the “Illness Marker” 
concept
Comparison between Healthy & Seriously
Sick Subject
Healthy Male 51 yrs
Impedance Index
"Illness Marker"
Frequency
5 kHz
573
50 kHz
100 kHz
200 kHz
480
450
433
Variance bw
5 and 200 kHz
140
Phase Angle
at 50 kHz
Reactance
at 50 kHz
7.3
61
Phase Angle
at 50 kHz
Reactance
at 50 kHz
2.9
27
0.756
"Dying" Male 58 yrs
Impedance Index
"Illness Marker"
Frequency
5 kHz
568
50 kHz
100 kHz
200 kHz
530
515
504
Variance bw
5 and 200 kHz
64
0.887
My grateful thanks
®
Bodystat
Ltd
Isle of Man
British Isles
www.bodystat.com