Field Day Power Ham Radio depends on Emergency Power! It’s a whole new world of Power Prius / Power / Energy / Solar Bob Bruninga 12 March 2010 www.aprs.org/APRS-SPHEV.html My Car 2004 Prius w $4000 of door/frame damage 200 W added Solar Panels 100 LBs of added Batteries On display at the IEEE PHEV Symposium in Wash DC 2007. Getting Good Gas Mileage 42 HP The best way. Just drive smaller cars!... Cheap! Getting Good Gas Mileage? 10-16 MPG USA Demand… Or is it Detroit Marketing? Why Fuel Efficiency? • Who was key-note speaker to Electric Vehicle Association? – Ex-head of CIA • Why is government interested in Fuel Economy? – $200,000,000 per day for Middle East Oil – How many Terrorists does that support? – Gas costs us $400/gallon in Afghanastan! • We *must* cut our dependence on Foreign Oil! – Iraq, Iran, etc – Venezuella, Russia Why Getting off Gas? “Peak Oil” What can we do about it? • Last century millions were killed for Salt – Salt was a global commodity – War-Lords controlled Salt Empires • What ended their reign? – Refrigerators! • Simple Technology can change Global Empires • Eliminating our addiction to Foreign Oil is how. • Electric Vehicles/ Solar can do it! Electric Vs Gas • 70% of our gas comes from overseas (bad!) • 99% of our electricity comes from USA! (good!) • At night we can charge 150,000,000 electric cars for only 7% of the total USA energy grid. • At night, electricity is cheaper (50% or less) and more plentiful • During Day Peak demand, electricity costs 10 times more • But those same 150,000,000 car batteries contain more peak power than FIVE TIMES the entire USA power generating capacity! • V2G (Vehicle-to-Grid) could offset $2000 per car in energy savings by letting the power companies buy some back during brief peak demands but still charge your car! Hybrid Efficiency VS Gas Well-to-Wheel Efficiency Prius Comparisons Don’t Believe Nay-Sayers or other rabid deniers and miss-information from entrenched status-quo Everything Counts Good Tire Pressure Air Flow underneath Low Emissions (Tank) Saving Energy (in the air-conditioner) Impact of Speed on Air Drag • Gas Engine Cars: – The main energy waste in town driving is stopping. – Low power demands is where gas engine is most inefficient – Hence better MPG on the open road. Electric limit • Hybrid: – Regenerative Braking saves most stopping energy for re-use. – Electric motors for optimum power at low speeds and power – Better mileage in town where AIR resistance is lowest. The Hybrid Synergy Drive • • • • 76 Hp ICE 50 kW MG1 50 kW MG2 Planetary Gear System • 50 kW Battery Atkinson Cycle Engine Planetary Gear System Three shafts Power sharing/balancing Any input, any output Motor/Generator The 50 kW Inverter Water cooled • 220 VDC to 500 VDC • 220 VDC to 12 VDC at 100 amps • 220 VDC to any motor voltage as needed (low gear) (High Gear) Regenerative Braking • 65% of all Prius Electric Power comes from Braking • Typically 35 amps at 250 volts • That’s almost 9,000 Watts But NO brakes is even better! Regenerative Braking Displays In 30 min commute, Engine runs only 11 mins • Energy Flow • Consumption Avoid Turtles! Instrument Panel (not)! • • • • • • No Tach No Vacuum No temperature No volts No current No power My add-on solution – an Analog panel Computers and CAN Bus Computers and CAN Bus Battery Specs Protecting the Battery Prius likes to keep the battery at 58% charge Solar PHEV & Battery 200 Watts of Solar Panels 200 W-hrs per hour in Sun $2400 cost. 200 W-hrs per mile needed My PHEV battery only needs to be half as big for the same EV range. Solar power while parked all day, gives half my electric need. Eighteen 12V batteries 9 Amp-Hours each 225 Volts 2025 Watt-Hours Solar - 4 Hrs per day. 4 Miles EV per trip. 40 mile commute = 10% improvement PHEV - 8 Hrs at night. 4 Miles EV per trip. 40 mile commute = 10% improvement Any Car can Benefit from Electric • Geo Tracker • Gains 15% from 26 • to 33 MPG Disconnect Fan belt (fan, alternator and water pump) Home Power Generation Home Solar 4 kW Gas 4 kW Wind 5 Kw Prius 50 kW peak (10 kW average) I was so wrong! I’ve been interested in solar power all my life But never had a real need other than just-for-fun No way was it cost effective Unless you had no other access to power… I was so wrong! • My concept of solar power was this: Battery Storage (off Grid) I was so wrong! • The problem is the Batteries! • My first energy system (1990) was Time-of-Use Metering – – – – – 2 cent electricity at night 10 cent electricity during the day! Why not charge batteries at night Run from batteries during the day Result: Breakeven – due to battery replacement every 5 yrs • Compared to 2 CENTS at night, solar never breakeven! – (if batteries lasted 5 years.. Not likely) • Conclusion… – Since solar power is NOT free, – seemed impossible to ever break even – (due to battery replacement cost) It’s a Whole New World! • Get rid of the Batteries! • Look AGAIN at the new economics! Grid-Tie It’s a Whole New World! Grid-Tie • Cost effective in EVERY state now! Grid-Tie Economics! • The problem is the Batteries – (Only 70% EFFICIENT)! – Grid-tie IS 95% EFFICIENT! Improvement (factor of 1.35) – No battery replacement costs $1000 per year (factor of 2) • Economics in 2010 compared to 2007 – Electricity cost has doubled! Factor of 2.0 – Solar panels cost has halved! Factor of 2.0 • Therefore It’s 11 times better NOW to go Solar • But Wait, there’s more! – Government Incentives! Grid-tie inverter Government Incentives! • Federal gives 30% tax credit. No limit – As much as $15,000 right into your pocket – Factor of 1.43! • State of Maryland Grant – For my 8kW system that’s a $7000 check in my pocket – $1.25 / W for first 2 kw, $.075 / W for next 6 kW – Factor of 1.3 • AA County Real Estate Tax credit – up to 50% of total remaining after above (Maybe $3000) – Factor of 1.13 • Total Gov’t Incentive Factors = 2.0 Total Cost Factors! • Grid-Tie versus no Batteries – Better by Factor of 2.7! • Economics of Electricity and Solar – X 2 (for higher rates) X 2 (for lower costs) = Factor of 4 • Tax credits and incentives – Factor of 2 • CONCLUSION: It makes 22 times more sense to go solar now than it did 3 years ago (if you think in terms of Battery Storage systems (typical for hams) like I did). But there’s more! (Return on Investment) • Solar Energy Credits (sell your Green energy credits) – About $250 /year /KW 10% return/yr • Electric Bill – Free Electricity for life – Cost of 0-net-grid-tie 10% return /yr - 5% cost /yr – (you still have to pay about $10 fixed costs even if you use no electricity) • Maintenance – Practically zero Total Return on Investment… about 12% per year Compare that to the banks (2% ?) or stock market (- 30% ?!) PLUS: your 12% only goes up as energy costs go up! But there’s more! (Do it yourself!) • Commercial system: • • • • • $25,000 for a 4kW system? Cost of solar panels $12,600 (18 at $700 vs $1000) Cost of inverter $2100 versus $3000 Cost of wire, disconnects, breakers, etc $200 Cost of Master Electrician to certify system $200 TOTAL about $15,000 Savings (DIY) $10,000 Tax credits, Grants, SREC’s etc $ 7,500 NET COST TO YOU… $ 7,500 Pays for itself in 4 years. Then FREE POWER for LIFE! But I’m a ham! I want Battery Backup…! • Why?.... • At what cost? $12,000? • For the 2 hours every 2 years you lose power? • For the 2 days you lose once every 10 years? • Makes practically zero economic sense! You pay about $240 / KWH over 10 years (compared to $0.12) (2000 times more!) But I’m a ham! I want Battery Backup…! You can have it! EASY AND CHEAP! $ 120 • Spend $120 for a 1200 Watt Inverter • Hook to your car battery • Power Refrigerator and lights in your house for days! • You do use CFL bulbs, right? But I’m a ham! You do use CFL bulbs, right? 25% of the power! 10 times the life + Air Conditioning savings of 5%! = 5:1 savings! Down to $1 each EER of 1-to-1 is 3.412 BTU/ watt. So with EER of 10, 100W bulb takes 30W of AC! Use of Piers for Solar/Wind prohibited Use of Piers for Solar/Wind prohibited • Rejected by MDE due to Pier Laws Solar Pier Argument • My house uses 10 MWHrs / yr • Coal Plant (for me) produces: •22,000 Lbs CO2 •350 lbs sulfur dioxide •1 Oz Uranium and Thorium •.02g of Mercury With 10 KW Array, pollutes Zero. 2.8 kW Solar Boat Work-around • Approved by DNR as Boat under 26’ Efficiency must > 80% To get Gov’t Credits Free Home Estimate includes sky survey Efficiency using PVwatts Grid-Tie implies surprising results! 100% South 94% SE 96% SW 85% FLAT! 120% 125% (battery system 65% worse and must be South) Portable Power Generation 350 W aux power 1200W AC inverter $120 Invert to 115 VAC For distribution 95% efficiency Saves 100:1 in wire losses Modern Power Distribution 9 amp 8 amp 18 amp Power Systems have CHANGED! Switching supply takes up 8% of the space and only 10% of the mass and works 100-240 VAC AND 150-330 VDC Power Distribution 330 VDC Nearly ALL modern switching supplies will run on VDC Double to 230 VAC at source Eliminate 75% of Rectify to 330 VDC for delivery Distribution losses Power Distribution 330 VDC Nearly ALL modern switching supplies will run on VDC Kenwood 115 VAC only supply Eliminate 75% of Actually has internal jumper Distribution losses Power Distribution ? Problem: 6 Hr ops from Hill top 3200’ from car Power Distribution SWER Single Wire Earth Return Not Double to 230 VAC at source Rectify to 330 VDC for delivery approved by NEC Power Distribution SWER Single Wire Earth Return Not approved by NEC 2 Laptops, 50W dual band, 2 HT’s and APRS – 6 Hours Golden Packet Event 26 July 2010 14 Hops Alabama to Maine! 2 Laptops, 50W dual band, 2 HT’s and APRS – 6 Hours Golden Packet Event 26 July 2010 14 Hops Alabama to Maine! Visit with Google Earth and Path tool Power Distribution SWER Emergency Power: Use Single Wire Earth Return Double to 230 VAC at source Rectify to 330 VDC for delivery Not approved by NEC Power Distribution SWER Emergency Power: Use Single Wire Earth Return 3200’ system fits in laptop bag Not approved by NEC Power Distribution SWER Emergency Power: Use Single Wire Earth Return Not approved by NEC Power Distribution SWER Emergency Power: Use Single Wire Earth Return Not approved by NEC Home Power Generation 50 kW peak (10 kW average) Safe, cheap connectors (Modified to prevent incorrect use.) Greater distances At half the current At twice the power #18 zip cord can carry 1000 watts easily Salvage Prius Toys P1 • 2004 in 2007 • Cost $10k • 29k Miles $2000 of solar panels Prius Inn Other Salvage Prius Toys 2005 in 2008 $7k, 19k miles 2005 in 2010 $6k, 90k miles P2 P2 Prius Hotel P3