Generator and/or Load Bank Docking Stations

advertisement
Trystar Generator Docking Stations &
Portable Power Cable
Trystar Generator and/or Load
Bank Docking Stations
Solutions to the problems associated with
quickly, safely and legally hooking up and
disconnecting portable generators before,
during and after extended power outages,
safely and economically load testing
permanent generators and maintaining
automatic transfer switches.
•
Standard Docking Station - Used to safely integrate a portable generator or load
bank into an existing electrical system that already has the necessary switching
means available.
100A -200A
1000A – 3200A
400A – 800A
Pad Mount with Cam-Lok
and hard wire, or extra buss
for feed thru applications
Features and Options
•
•
•
•
•
•
•
•
•
•
•
•
Tamper Resistant - Patented “Rake System” prohibits removal or tampering with
Cam-Lok cables while in use and bottom door eliminates unwanted pests when
locked and not in use.
Tuffcoat Textured Powder Coating – Standard ANSI Gray or specific color, tough
scratch and UV resistant.
Aluminum or Stainless Steel Construction
Kirk Key Interlocks for access or on breakers
Phase Rotation Monitor – Indicates correct phase rotation of generator hookup for
phase sensitive equipment such as A/C, chillers and pumps.
All required lugs for building, utility and/or generator – specify mechanical or crimp
“Utility On” LED – Lets you know that utility power is back on.
Leg Kits – Allows for pad mounting wall units
Extra Depth Units – Allows for additional wiring and/or bottom conduit access for
wall units.
Power Outlets – When required for battery chargers and block heaters
2 Wire Auto Start – Required for ATS interface
SCADA Monitoring Port
Various Switching Methods
•
•
•
•
•
•
Kirk Key Access Docking Station – Utilizes a captive key interlock in a building or
permanent generator’s existing “Main Breaker” or disconnect as the means of
isolating the primary power source.
Manual Rotary - Docking Station and manual transfer switch are in one common
enclosure. Available in Service or Non Service Entrance Rated. Available up to 1200A.
Automatic – Docking Station is wired to ATS and setup with 2 wire auto start, 120V
outlet for battery charger and block heater. If intercepting utility feed, the switch
must be Service Entrance Rated with a Main Breaker. No amperage restriction.
“Main Breaker” Kirk Key Access Docking Station - If a facility or generator has no
single “Main Breaker”, this unit supplies the Kirk Key “Main” and the “Kirk Key
Accessible” Cam-Loks.
Single or Dual Breaker Kirk Key Docking Station – Used when a combination of
“Main Breaker”, portable generator breaker, permanent generator breaker, load bank
or ATS By-Pass Isolation breaker is needed.
Combinations of the above - The Trystar Docking Station System is designed to
integrate all of the individual features to meet any type of application, giving the
project’s owner, engineer, contractor and salesmen the versatility and flexibility to
get the best, safest and most economical system available.
Kirk Key Accessible Generator Docking Station
Kirk Key Accessible Wall or Pad Mount
Docking Stations
Rotary Transfer Switch Docking Stations
•
•
•
•
•
•
•
•
Manual Rotary - Docking Station and manual transfer switch are in one common
enclosure.
Available as Service or Non Service Entrance Rated. Available up to 1200A UL and
3000A Non UL IEC.
Compact Stacked Open Transition Rotary Transfer Switch.
Breaker for Service Entrance Rated, no bulky fuses to locate if blown.
NEMA 3R and 4X UL listed.
Available in aluminum or stainless and powder coated any color.
Available with lockable external load bank receptacles for permanent generator.
Available in wall or pad mount designs.
Automatic Transfer Switch with Docking Station
•
•
•
•
•
•
•
•
•
Automatic Transfer Switch with Docking Station - Docking Station mounted and wired to
any automatic transfer switch.
Available as Service or Non Service Entrance Rated. Available up to 4000A.
Includes 2 wire auto start terminal and phase rotation monitor.
Available with battery charger and water heater outlets.
Available in NEMA 3R and 4X UL listed.
Available in aluminum or stainless and powder coated any color.
Available with lockable external load bank receptacles for permanent generator.
Available in wall or pad mount designs.
Customer can drop ship their ATS, have Trystar mount and wire the Docking Station,
repackage and then deliver to the job site.
Main Breaker & Kirk Key Accessible
Portable Generator Docking Stations
•
•
•
•
•
•
•
•
•
•
Main Breaker and Kirk Key Accessible Portable Generator Docking Station- Pad mount
Generator Docking Station with Kirk Keyed Utility Main Breaker and “Kirk Key Accessible”
Portable Generator input cam-loks and hardwire lugs.
For buildings that have multiple (up to 6) main disconnects on one utility feed or building
that have their main in a centrally located and hard to access part of the building.
Recommended by Fire and Electrical Inspectors for easy and quick external disconnect in
the case of a building fire.
Service Entrance Rated. Available up to 4000A UL.
NEMA 3R and 4X UL listed.
Phase Rotation Monitor.
Lockable and tamper resistant while in use.
Side and back access panels.
Available in aluminum or stainless and powder coated any color.
Available with load bank receptacles for permanent generator.
Dual Purpose Combination Units
•
•
•
•
•
•
•
•
•
•
Wall, pad or generator mounted
Load bank receptacles – significantly reduces
service and down time, eliminates chance of
incorrect wiring.
Allows service company to do more load tests
per week.
Allows for quick access to portable generator
while permanent unit is being serviced.
Optional ATS By-Pass Kirk Key Breaker System
Optional SCADA communication port available
for load bank load drop, leaves fans running to
cool down load bank.
Portable generator Kirk Key Breaker or Kirk Key
Access.
Portable generator cam-lok inlets and internal
hardwire access door.
Phase Rotation Monitor, 2 wire auto start
terminal, auxiliary power outlets.
Feed through bussing and lugs.
QUESTIONS???
It has been our pleasure to meet with you
all today.
Thank-you!
Download