INTRODUCING The 5502A Fluke’s Newest Multi-Product Calibrator Robust, Transportable, Wide Workload Coverage The best fit and value for your calibration workload! The NEW 5502A Multi Product Calibrator Improved confidence in calibration…… Offers the best that the leading Fluke 5500A and 9100 provide as calibrators – and then adds robust protection & easy transportability New 5502A at a glance The best range of functions, accuracy and value in its class • • • • • • • Voltage to 1020V dc or ac Current to 20.5 A, dc or ac Fully variable resistance to 1100 MΩ AC/DC power with variable phase Continuously variable capacitance to 110 mF More than 18 temperature calibration functions for thermocouples or RTDs Options to calibrate oscilloscopes to 600 MHz Built with the improved 5522A platform with 5500 level performance specs Recessed banana style terminals Additional terminal outputs up to 20.5 A 300 MHz and 600 MHz Scope Options What will 5502A offer? • Incorporating the 9100’s functional capabilities not now in the 5500A 20.5 Amps ac & dc • Adding the new & successful improvements of the 5522A: Wider resistance and capacitance ranges Input Overload Protection Transportability A new look • Based on the 5522A technology with banana plug connection terminals • It continues to offer a calibrator that is fully automatable via GPIB or RS-232 Interfaces Red indicates improved specs versus the 5500A and/or 9100 Function Range “Best” 1 Yr Spec DC Voltage 0 to 1020V 50 PPM AC Voltage 220 mV to 1020V @ 10 Hz to 500 kHz 300 PPM DC Current 0 to 20.5A 100 PPM AC Current 9 μA to 20.5A @ 10 Hz to 30 kHz 900 PPM Resistance 0 to 1.10 GΩ 90 PPM Capacitance 220pf – 110mF 0.25% AC & DC Power 0 to 20.9 kW/VAR Variable Phase 0 to ±180.00 degrees 0.15 Degrees Thermocouple source 11 types plus 10 µV / C° & 1 mV / C° 0.14 C° RTD source 8 types of Pt and Cu RTDs 0.04 C° Thermocouple measure 11 types plus 10 µV / C° & 1 mV / C° 0.14 C° Frequency 0.01 to 2 MHz 25 ppm Scope Cal 300 MHz and 600 MHz options various The 5502A Multi Product Calibrator – Improved Performance Improved current – 20.5 Amps & more • Current to 20.5A dc or ac – Strong Compliance • 4 to 10 volts dc • 3 to 7 volts ac – Extendable to 120A with the 52120A Transconductance Amplifier! • DC voltage accuracy at 40 ppm (90 days) and 50 ppm (1 year) • Variable resistance 0 to 1100 MΩ • Variable capacitance 220 pf to 110 mF The 5502A Multi Product Calibrator – Confidence in Workload Calibrates one of the widest workloads of any electrical calibrator on the market • Handheld and bench meters (analog and digital) up to 4½ digits • Current clamps and clamp meters • Thermocouples and RTDs • Process calibrators • Data loggers • Strip and chart recorders • Watt meters • Power harmonics analyzers • Panel meters • Graphical multimeters • Analog or digital handheld and bench oscilloscopes to 600 MHz …..and more The 5502A Multi Product Calibrator – Confidence in Reliability NEW – Premium Input Protection • Reverse power protection to 300V peak and more, with immediate output disconnect on all terminals • “Check before Connect” process • Replaceable over-current fuses • NO COMPROMISE performance specs with the new protection systems The 5502A Multi Product Calibrator – Confidence in Usability New larger, open, and more comfortable handles – mean it is designed to easily and comfortably move to where it is needed – Easier access to the output binding posts mean fast and reliable test lead connections More of what’s new – It is easily transported • A new Carry Case with wheels and removable front & rear covers – Gets out of the lab and to the job, and back – easily – Set up for the on-site and in-situ calibrations is simple with removable covers Easy to move, setup & calibrate Benefits of the 5502A In short it is … CONFIDENCE The NEW 5502A gives its users confidence More than 11 electrical calibration functions for wide workload coverage with an excellent value + Robust Protection, Easy transportability A Closer Look At….. OVERLOAD PROTECTION Common overload damage On other calibrators one accidental electrical overload can damage up to 3 internal circuits/systems & the main system board Blown Chips Burned Circuit Assemblies COSTLY REPAIRS $$$$ 5502A offers protection from these common errors Examples of successful protection What if a technician accidentally connects ……. • • • • • • AC mains voltage into the resistance terminals no damage The calibrator’s test leads to live voltage terminals calibrating an in-situ panel meter no damage A thermocouple pair with large a common mode voltage into the TC terminals no damage A Meg ohm meter, initiates a test which applies 100s of volts into the resistance terminals no damage A high voltage to ANY Normal, AUX or TC connection terminal no damage An external current source to the AUX terminals and drives a current into the calibrator only the protection fuses need replacement Benefits of the overload protection Reverse power protection Immediate output disconnect Check before connect Fuse protection • With the added capabilities the calibrator will withstand accidental overloads, warn the operator of the error, and continue to calibrate properly – with no damage • Eliminates costly repairs • No downtime or lost productivity A Closer Look At….. AUTOMATED CALIBRATION Easy Automation of a 5502A MET/CAL Compatibility • 5502A works seamlessly with the MET/CAL version 8.1, and future versions • Easy upgrades of earlier systems through MetSupport Gold or as a purchased upgrade • The new NVI format for MET/CAL makes procedure writing easier and insures strong future compatibility • Existing 5500A and 9100A procedures will need to be translated to the new format when used with the 5502A Full Remote Control Command Compatibility • 5502A remote control programming is identical to 5500 series • Only the instrument identification response is the different (5502A rather than 5500A) A Closer Look At….. 5502A & FLUKE’S OTHER MULTI PRODUCT CALIBRATORS The 5080A, 5502A & 5522A Function Comparison The 5080A, 5502A & 5522A Workload Comparison Points of differentiation with 5500A 5502A 5500A Max 20.5 A of dc and ac current Max 11 A of dc and ac current 1100 M ohms max variable resistance 330 M ohms max variable resistance 220 pF to 110 mF variable capacitance 330 pF to 1.1 mF variable capacitance Input terminal protection to 300V Separate Hi current output terminal Improved chassis design Ergonomic handles 20 Points of differentiation with 9100 5502A 9100 Basic dc accuracy is 50 ppm / year Basic dc accuracy is 60 ppm / year 1100 M ohms max variable resistance 400 M ohms max variable resistance ACV to 500 kHz ACV to 100 kHz 220 pF to 110 mF variable capacitance 500 pF to 40 mF variable capacitance .01 Hz to 2 MHz Frequency 0.5 Hz to 10 MHz Frequency Little or no practical benefit to user No such function available (recommend a 5320A or optional with 5080A) Obsolete and not available (use MET/CAL or computer automation) Lead connection mat 9100-135: Insulation/Continuity Tester Calibration Module 21 PCMCIA Storage Modules The 5502A Multi Product Calibrator OPTIONS & ACCESSORIES….. 5502A Scope Calibration Options 5500A-SC300 with Leveled Sine to 300 MHz, rise time < 1ns 5520A-SC600 with Leveled Sine to 600 MHz, rise time < 300 ps • Supports the following functions: – – – – – – – – – – DC Voltage AC Voltage (Square wave) Fast Edge Leveled Sine wave Time Markers Wave Generator Pulse Generator TV Trigger Input impedance Measurement Overload Measurement • All single test channel plus a trigger channel Instrument Case Accessories • A transportation case to serve the workload both in and out of the lab • 5522A/CARRYCASE – The 5522A/CARRYCASE is intended for lab managed travel over short or medium distances – Wheels & handle make for easy transportation – Quick removable covers mean fast set up and in the case usage • A rugged, padded shipping case for transportation outside of the lab’s • 55XX/CASE control – The 55XX/CASE is designed to withstand difficult shipping conditions found with public & third party freight carriers – The best solution for long distance shipping by carries who don’t use the same careful attention as does the lab 5500A-525A/Leads Accessory Kit •Have a complete assortment of leads needed for the full range electrical voltage, current, and thermocouple connections •The 5500A/LEADS set additionally contains 4 safety leads that aren’t compatible with the 5522A or 525B binding post style terminals Current Coil Accessories 5500A/COIL 50 Turn Coil 9100-200 10 & 50 Turn Coil MET/CAL Plus Software Key Benefits of Automation • One common software platform across a wide range of workload • Perform calibrations quickly and efficiently. • Boost cal lab productivity. • Calibrate mechanical and dimensional instruments and more. • Manage all calibration assets in a single MET/TEAM database. • Keep data secure. For More Detailed Information • 5502A Product Brochure – Discusses workload, transportability and automation – A close up profile of the 5502A – Promotes Fluke’s MPC family with a summary of all 3 multiproduct calibrators • 5522A • 5502A • 5080A • Extended Specifications Data Sheet – Full official specifications as published in the manual • Either are available in hardcopy or electronic media • Visit http://www.fluke.com/5502A Mainframe Models & Accessories Model 5502A Description MULTI-PRODUCT CALIBRATOR 5502A/3 MULTI-PRODUCT CALIBRATOR + 300MHZ SCOPE OPT 5502A/6 MULTI-PRODUCT CALIBRATOR + 600 MHZ SCOPE OPT Accessory Description 55XX/CASE 5522A/CARRYCASE Transit Case 5522A Carry Case With Removable Front/Back Panels 5500A/LEADS Comprehensive Test Lead Kit for 5502A 5500A/COIL 9100-200 50 Turn Current Coil 10 and 50 turn Current Coils Y5537 5500A/HNDL Rack Mount Kit 7" for 5500A Side Handle 5800A-7002K 5800A-7004K 2 Output Cable Set 5800A Calibrator BNC Connector Kit Frequently Asked Questions Frequently Asked Questions 1. What comes standard with the 5502A calibrator? The 5502A calibrator comes standard with all its various electrical functions. Scope calibration capability is optional. Included is a full report of calibration with data. An accredited report of calibration is optional. 2. What options can be installed in the 5502A? The two scope calibration options (300 MHz and 600 MHz) are the only options for this calibrator. These are available at time or purchase or installed by a service center at a future date as an upgrade. 3. Is MET/CAL compatible with the 5502A? Yes MET/CAL Release Version 8.1 is able to fully control the 5502A (Due out in Q3 2012). 4. How will existing MET/CAL users get this version of MET/CAL? Upgrades are available through the MetSupport Gold program, or as a purchased upgrade to an existing system. 31 Frequently Asked Questions 5. Will existing MET/CAL 5500 or 9100 procedures work with the 5502A? No, because the calibrator’s output terminal configuration is different – and the resulting operator safety issues – a different FSC must be used to operate the 5502A with MET/CAL (rather than use the existing 5500A or 9100 FSCs). 6. Will the 5502A FSC use the old 5500A style syntax, or the newer 5522A style syntax? The 5502A will use the new Name Value Instrument syntax (NVI) – giving the user better flexibility in use, editing, and future calibrator upgrade compatibility. The 5500A used the old FSC syntax style MET/CAL implemented the 5502A with the new structure of FSC, similar to the 5522A FSC. As a result any 5500A procedures will need to be converted to the new FSC syntax. This can be done by the MET/CAL user, or by a translator process. More information on the translation process will soon to be furnished by the MET/CAL team. Similarly any existing 9100 procedures will need to be translated to the new 5502A MET/CAL FSC syntax. 32 Frequently Asked Questions 7. Does the 5502A use same the commands of other Fluke 55XX calibrators? Yes the 5502A uses the same remote control commands as the earlier 5500A, 5520A and 5522A series calibrators. The only difference is that it answers the remote ID command with a response - that of being a 5502A. 8. Does the 5502A emulate the commands of Fluke/Wavetek 9100 calibrators? No the 5502A does not emulate the Fluke/Wavetek 9100 calibrator remote control commands. 9. What is the future availability of the 5500A calibrator? The 5500A will be phased out approximately 6 months after the 5502A introduction. 10. What is the future availability of the 9100 calibrator? The 9100 will soon go on limited availability with a last time buy period soon. 11. Is 5500A upgradable to 5502A? No a 5500A is not upgradeable to a 5502A. 33 Frequently Asked Questions 12. Is 5502A upgradable to 5522A? No a 5502A is not upgradeable to a 5522A. 13. Will the user/operator manual be available together with 5502A at the same time? Yes, a full user’s manual will be available with the 5502A, in English language, supplied on a CD/DVD with the instrument. The getting started manual will translated in several languages, printed and supplied with the instrument. 14. Is the calibration procedure to calibrate the 5502A will be the same as 5500A? The performance verification procedure for the 5502A is similar, but not identical to the 5500A procedure. There are some range and specification differences between the two instruments. 15. Is a service manual available for the 5502A? A detailed service manual will be available at approximately one year after introduction. 34 The NEW 5502A = CONFIDENCE What the cal lab loved about the 5500A & 9100 is still there – More than 11 Functions for wide workload coverage • We have added improved performance and functionality – – – – Accuracy Current Resistance Capacitance plus… – Robust protection – Easy use & transportation THANK YOU FOR YOUR ATTENTION