The 5502A
Fluke’s Newest
Multi-Product Calibrator
Robust,
Transportable,
Wide Workload Coverage
The best fit and value
for your calibration workload!
The NEW 5502A
Multi Product Calibrator
Improved confidence in
calibration……
Offers the best that the leading Fluke
5500A and 9100 provide as
calibrators –
and then adds
robust protection & easy
transportability
New 5502A at a glance
The best range of functions, accuracy and value in its class
•
•
•
•
•
•
•
Voltage to 1020V dc or ac
Current to 20.5 A, dc or ac
Fully variable resistance to 1100 MΩ
AC/DC power with variable phase
Continuously variable capacitance to 110 mF
More than 18 temperature calibration functions for thermocouples or RTDs
Options to calibrate oscilloscopes to 600 MHz
Built with the improved
5522A platform with 5500
level performance specs
Recessed
banana style
terminals
Additional
terminal outputs
up to 20.5 A
300 MHz and
600 MHz Scope
Options
What will 5502A offer?
• Incorporating the 9100’s
functional capabilities not
now in the 5500A
 20.5 Amps ac & dc
• Adding the new & successful
improvements of the 5522A:
 Wider resistance and
capacitance ranges
 Input Overload Protection
 Transportability
 A new look
• Based on the 5522A
technology with banana plug
connection terminals
• It continues to offer a
calibrator that is fully
automatable via GPIB or
RS-232 Interfaces
Red indicates improved specs versus
the 5500A and/or 9100
Function
Range
“Best” 1 Yr Spec
DC Voltage
0 to 1020V
50 PPM
AC Voltage
220 mV to 1020V @ 10 Hz to 500 kHz
300 PPM
DC Current
0 to 20.5A
100 PPM
AC Current
9 μA to 20.5A @ 10 Hz to 30 kHz
900 PPM
Resistance
0 to 1.10 GΩ
90 PPM
Capacitance
220pf – 110mF
0.25%
AC & DC
Power
0 to 20.9 kW/VAR
Variable
Phase
0 to ±180.00 degrees
0.15 Degrees
Thermocouple
source
11 types plus 10 µV / C° & 1 mV / C°
0.14 C°
RTD source
8 types of Pt and Cu RTDs
0.04 C°
Thermocouple
measure
11 types plus 10 µV / C° & 1 mV / C°
0.14 C°
Frequency
0.01 to 2 MHz
25 ppm
Scope Cal
300 MHz and 600 MHz options
various
The 5502A Multi Product Calibrator –
Improved Performance
Improved current – 20.5 Amps & more
• Current to 20.5A dc or ac
– Strong Compliance
• 4 to 10 volts dc
• 3 to 7 volts ac
– Extendable to 120A with the 52120A
Transconductance Amplifier!
• DC voltage accuracy at 40 ppm (90
days) and 50 ppm (1 year)
• Variable resistance 0 to 1100 MΩ
• Variable capacitance 220 pf to 110 mF
The 5502A Multi Product Calibrator –
Confidence in Workload
Calibrates one of the widest workloads of any electrical
calibrator on the market
•
Handheld and bench meters (analog
and digital) up to 4½ digits
• Current clamps and clamp meters
• Thermocouples and RTDs
• Process calibrators
• Data loggers
• Strip and chart recorders
• Watt meters
• Power harmonics analyzers
• Panel meters
• Graphical multimeters
• Analog or digital handheld and
bench oscilloscopes to 600 MHz
…..and more
The 5502A Multi Product Calibrator –
Confidence in Reliability
NEW – Premium Input Protection
• Reverse power protection to 300V
peak and more, with immediate
output disconnect on all terminals
• “Check before Connect” process
• Replaceable over-current fuses
• NO COMPROMISE performance specs
with the new protection systems
The 5502A Multi Product Calibrator –
Confidence in Usability
New larger, open, and more
comfortable handles
– mean it is designed to easily
and comfortably move to where
it is needed
– Easier access to the output
binding posts mean fast and
reliable test lead connections
More of what’s new –
It is easily transported
• A new Carry Case with wheels and
removable front & rear covers
– Gets out of the lab and to the job,
and back – easily
– Set up for the on-site and in-situ
calibrations is simple with
removable covers
Easy to move, setup &
calibrate
Benefits of the 5502A
In short it is …
CONFIDENCE
The NEW 5502A
gives its users confidence
More than 11 electrical
calibration functions for
wide workload coverage
with an excellent value
+
Robust Protection,
Easy transportability
A Closer Look At…..
OVERLOAD PROTECTION
Common overload damage
On other calibrators one accidental electrical
overload can damage up to 3 internal
circuits/systems & the main system board
Blown Chips
Burned Circuit Assemblies
COSTLY REPAIRS $$$$
5502A offers protection from these
common errors
Examples of successful protection What if a technician accidentally connects …….
•
•
•
•
•
•
AC mains voltage into the resistance terminals
no damage
The calibrator’s test leads to live voltage terminals
calibrating an in-situ panel meter
no damage
A thermocouple pair with large a common mode voltage
into the TC terminals
no damage
A Meg ohm meter, initiates a test which applies 100s of
volts into the resistance terminals
no damage
A high voltage to ANY Normal, AUX or TC connection
terminal
no damage
An external current source to the AUX terminals and drives
a current into the calibrator
only the protection fuses need replacement
Benefits of the overload protection




Reverse power protection
Immediate output disconnect
Check before connect
Fuse protection
• With the added capabilities the
calibrator will withstand
accidental overloads, warn the
operator of the error, and
continue to calibrate properly –
with no damage
• Eliminates costly repairs
• No downtime or lost
productivity
A Closer Look At…..
AUTOMATED CALIBRATION
Easy Automation of a 5502A
MET/CAL Compatibility
• 5502A works seamlessly with the MET/CAL
version 8.1, and future versions
• Easy upgrades of earlier systems through
MetSupport Gold or as a purchased upgrade
• The new NVI format for MET/CAL makes
procedure writing easier and insures strong
future compatibility
• Existing 5500A and 9100A procedures will
need to be translated to the new format
when used with the 5502A
Full Remote Control Command
Compatibility
• 5502A remote control programming is
identical to 5500 series
• Only the instrument identification response is
the different (5502A rather than 5500A)
A Closer Look At…..
5502A & FLUKE’S OTHER MULTI
PRODUCT CALIBRATORS
The 5080A, 5502A & 5522A
Function Comparison
The 5080A, 5502A & 5522A
Workload Comparison
Points of differentiation with 5500A
5502A
5500A
Max 20.5 A of dc and ac current
Max 11 A of dc and ac current
1100 M ohms max variable resistance
330 M ohms max variable resistance
220 pF to 110 mF variable capacitance
330 pF to 1.1 mF variable capacitance
Input terminal protection to 300V
Separate Hi current output terminal
Improved chassis design
Ergonomic handles
20
Points of differentiation with 9100
5502A
9100
Basic dc accuracy is 50 ppm / year
Basic dc accuracy is 60 ppm / year
1100 M ohms max variable resistance
400 M ohms max variable resistance
ACV to 500 kHz
ACV to 100 kHz
220 pF to 110 mF variable capacitance
500 pF to 40 mF variable capacitance
.01 Hz to 2 MHz Frequency
0.5 Hz to 10 MHz Frequency
Little or no practical benefit to user
No such function available (recommend a
5320A or optional with 5080A)
Obsolete and not available (use MET/CAL or
computer automation)
Lead connection mat
9100-135: Insulation/Continuity Tester
Calibration Module
21
PCMCIA Storage Modules
The 5502A Multi Product Calibrator
OPTIONS & ACCESSORIES…..
5502A Scope Calibration Options
5500A-SC300 with Leveled Sine to 300 MHz, rise time < 1ns
5520A-SC600 with Leveled Sine to 600 MHz, rise time < 300 ps
• Supports the following
functions:
–
–
–
–
–
–
–
–
–
–
DC Voltage
AC Voltage (Square wave)
Fast Edge
Leveled Sine wave
Time Markers
Wave Generator
Pulse Generator
TV Trigger
Input impedance Measurement
Overload Measurement
• All single test channel plus a
trigger channel
Instrument Case Accessories
• A transportation case to serve the
workload both in and out of the lab
• 5522A/CARRYCASE
– The 5522A/CARRYCASE is intended
for lab managed travel over short or
medium distances
– Wheels & handle make for easy
transportation
– Quick removable covers mean fast
set up and in the case usage
• A rugged, padded shipping case for
transportation outside of the lab’s
• 55XX/CASE
control
– The 55XX/CASE is designed to
withstand difficult shipping conditions
found with public & third party freight
carriers
– The best solution for long distance
shipping by carries who don’t use the
same careful attention as does the
lab
5500A-525A/Leads Accessory Kit
•Have a complete assortment of
leads needed for the full range
electrical voltage, current, and
thermocouple connections
•The 5500A/LEADS set
additionally contains 4 safety
leads that aren’t compatible with
the 5522A or 525B binding post
style terminals
Current Coil Accessories
5500A/COIL 50 Turn Coil
9100-200 10 & 50 Turn Coil
MET/CAL Plus Software
Key Benefits of
Automation
• One common software
platform across a wide range
of workload
• Perform calibrations quickly
and efficiently.
• Boost cal lab productivity.
• Calibrate mechanical and
dimensional instruments and
more.
• Manage all calibration assets
in a single MET/TEAM
database.
• Keep data secure.
For More Detailed Information
• 5502A Product Brochure
– Discusses workload,
transportability and automation
– A close up profile of the 5502A
– Promotes Fluke’s MPC family with
a summary of all 3 multiproduct
calibrators
• 5522A
• 5502A
• 5080A
• Extended Specifications Data
Sheet
– Full official specifications as
published in the manual
• Either are available in hardcopy
or electronic media
• Visit http://www.fluke.com/5502A
Mainframe Models & Accessories
Model
5502A
Description
MULTI-PRODUCT CALIBRATOR
5502A/3
MULTI-PRODUCT CALIBRATOR + 300MHZ SCOPE OPT
5502A/6
MULTI-PRODUCT CALIBRATOR + 600 MHZ SCOPE OPT
Accessory
Description
55XX/CASE
5522A/CARRYCASE
Transit Case
5522A Carry Case With Removable Front/Back Panels
5500A/LEADS
Comprehensive Test Lead Kit for 5502A
5500A/COIL
9100-200
50 Turn Current Coil
10 and 50 turn Current Coils
Y5537
5500A/HNDL
Rack Mount Kit 7" for 5500A
Side Handle
5800A-7002K
5800A-7004K
2 Output Cable Set
5800A Calibrator BNC Connector Kit
Frequently
Asked
Questions
Frequently Asked Questions 1. What comes standard with the 5502A calibrator? The 5502A
calibrator comes standard with all its various electrical functions.
Scope calibration capability is optional. Included is a full report of
calibration with data. An accredited report of calibration is optional.
2. What options can be installed in the 5502A? The two scope
calibration options (300 MHz and 600 MHz) are the only options for
this calibrator. These are available at time or purchase or installed
by a service center at a future date as an upgrade.
3. Is MET/CAL compatible with the 5502A? Yes MET/CAL Release
Version 8.1 is able to fully control the 5502A (Due out in Q3 2012).
4. How will existing MET/CAL users get this version of MET/CAL?
Upgrades are available through the MetSupport Gold program, or
as a purchased upgrade to an existing system.
31
Frequently Asked Questions 5. Will existing MET/CAL 5500 or 9100 procedures work with the
5502A? No, because the calibrator’s output terminal configuration is
different – and the resulting operator safety issues – a different FSC
must be used to operate the 5502A with MET/CAL (rather than use
the existing 5500A or 9100 FSCs).
6. Will the 5502A FSC use the old 5500A style syntax, or the newer
5522A style syntax? The 5502A will use the new Name Value
Instrument syntax (NVI) – giving the user better flexibility in use,
editing, and future calibrator upgrade compatibility.
The 5500A used the old FSC syntax style MET/CAL implemented the
5502A with the new structure of FSC, similar to the 5522A FSC. As a
result any 5500A procedures will need to be converted to the new
FSC syntax. This can be done by the MET/CAL user, or by a
translator process. More information on the translation process will
soon to be furnished by the MET/CAL team.
Similarly any existing 9100 procedures will need to be translated to
the new 5502A MET/CAL FSC syntax.
32
Frequently Asked Questions 7. Does the 5502A use same the commands of other Fluke 55XX
calibrators? Yes the 5502A uses the same remote control
commands as the earlier 5500A, 5520A and 5522A series
calibrators. The only difference is that it answers the remote ID
command with a response - that of being a 5502A.
8. Does the 5502A emulate the commands of Fluke/Wavetek 9100
calibrators? No the 5502A does not emulate the Fluke/Wavetek
9100 calibrator remote control commands.
9. What is the future availability of the 5500A calibrator? The
5500A will be phased out approximately 6 months after the 5502A
introduction.
10. What is the future availability of the 9100 calibrator? The 9100
will soon go on limited availability with a last time buy period soon.
11. Is 5500A upgradable to 5502A? No a 5500A is not upgradeable
to a 5502A.
33
Frequently Asked Questions 12. Is 5502A upgradable to 5522A? No a 5502A is not upgradeable to a
5522A.
13. Will the user/operator manual be available together with 5502A at
the same time? Yes, a full user’s manual will be available with the
5502A, in English language, supplied on a CD/DVD with the
instrument. The getting started manual will translated in several
languages, printed and supplied with the instrument.
14. Is the calibration procedure to calibrate the 5502A will be the
same as 5500A? The performance verification procedure for the
5502A is similar, but not identical to the 5500A procedure. There are
some range and specification differences between the two
instruments.
15. Is a service manual available for the 5502A? A detailed service
manual will be available at approximately one year after introduction.
34
The NEW 5502A = CONFIDENCE
What the cal lab loved about
the 5500A & 9100 is still
there
– More than 11 Functions
for wide workload
coverage
•
We have added improved
performance and
functionality
–
–
–
–
Accuracy
Current
Resistance
Capacitance
plus…
– Robust protection
– Easy use & transportation
THANK YOU FOR YOUR
ATTENTION
Download