TLC Experiment Notes:
Procedure:
Compound Prep:
1. Gather all necessary chemicals for the TLC procedure + the materials:
CHEMICALS, Hexanes, Ethyl Acetate, Acetone, TLC spotter, TLC plate,
TLC Solvent Jar, BLANK 1 Dram Vials, pencil, tweezers, 5 mL graduated
cylinder, 3 glass pipets, aluminum foil, filter paper.
2. Measure out 10-15mg of the BLANK into a tared, clean, and labeled, 1
dram vial using an analytical balance.
3. Using the clean 5 mL graduated cylinder, measure out 1 mL of acetone and
add it into the BLANK’S 1 dram vial. Do so in the fume hood.
4. Swirl the dram vial until the solution is homogenous, and then cover with the
aluminum foil to prevent evaporation in the fume hood.
Solvent Creation:
1. Using a 5mL graduated cylinder, measure out 5 mL of a 8:2 hexanes:ethyl
acetate solvent mixture (measure out 4 mL of hexanes and 1 mL of ethyl
acetate). Add the mixture into the clean TLC solvent jar.
2. Using a clean glass pipet add 3 drops of acetic acid to the jar to prevent
streaking of carboxylic acids during the TLC run.
3. Place a filter paper on the inside of the jar bent towards the side so there is still
space for a TLC plate.
4. Cover the TLC jar to ensure of the solvent no evaporation occurs.
TLC Plate Setup:
1. Hold an unchipped TLC plate next to the solvent jar and draw a baseline
horizontally above the solvent line of the jar using a pencil.
2. Make BLANK tick marks on the baseline of the plate where the spotting of
BLANK will occur. Use a pencil.
3. Gently label the tick marks.
4. Dip a clean TLC spotter into the BLANK sample and ensure no hanging drops
are present. If so, tap them off into the vial.
5. Gently touch the spotter to the labeled tick mark as accurately along the baseline
as possible.
6. If another sample is done, use another TLC spotter.
7. Check the TLC plate under UV light to see the spots on the baseline.
TLC Run:
1. Grab the TLC plate with either a gloved hand or a tweezers (always wear
gloves), and lower it slowly/gently into the TLC jar.
2. Cap the jar and let the TLC test run.
3. Let the plate develop until the solvent front is only around 1 cm away from the top
of the plate.
4. Uncap the jar and remove the plate, and immediately mark the solvent front line
with a pencil.
5. Put the TLC plate under the UV light again and mark the spots by gently circling
them with a pencil.
6. Calculate the Rf values for the spots present on the plate.
7. If more than one plate, repeat steps 1-6 of TLC run.
Rf Calculation:
Rf = (distance from baseline to center of spot) / (distance from baseline to solvent front)
Notes:
- Optimal Solvent (Rf):
o Spots are separated by at least 0.2 Rf units
o Rf value of the more polar compound should be at least 0.3.
- More polar compound interacts with stationary phase more (closer to baseline)
- Less polar compound interacts with mobile phase more (further from baseline)
- Visualizing Spots on Plate:
o Colored compounds are seen by light
o Most times. = UV light required compounds must be conjugated
o Conjugated = alternating series of sigma and pi bonds.
o Stains can be used as well. Ex: potassium permanganate.
- Rf values are useful for identifying an unknown compound.
Trouble Shooting Tips:
1. Large and Blobby Spots
a. Fix by either spotting less on the baseline or diluting the sample (increase
acetone solvent).
2. Streaking Spots
a. Happens with especially polar compounds (like carboxylic acid)
i. Add 3 drops of acetic acid
3. Diagonal Spots
a. Happens if TLC plate is placed into the jar not straight down. The solvent
runs at an angle. Run next plate straight up and down.
4. Spots Close Together
a. Change the solvent mixture: decrease polarity (more hexanes) or vice
versa.
i. If spots need to travel further- increase polarity (more eth.ace)
ii. If spots need to travel less- decrease polarity (more hexanes)
5. No Visible spots = Too dilute