Uploaded by yaru sun

Get Valid Hitachi HQT-4420 Dumps (V8.02) for Exam Preparation

advertisement
DUMPS
BASE
EXAM DUMPS
HITACHI
HQT-4420
28% OFF Automatically For You
Hitachi Vantara Qualified Professional - Content
Platform Installation
id
H
it
ac
hi
H
Q
T
-4
42
0
D
um
ps
(V
8.
02
)
fo
r
E
xa
m
P
re
pa
ra
ti
on
1.Which two statements are correct regarding hardware upgrades on an HCP G10
system? (Choose two.)
A. Mixed clusters consisting of both G10 servers and CR servers are not allowed
B. Node additions are performed using the Configuration menu of the HCP setup
program
C. Upgrades can be performed online or offline
D. Data is automatically rebalanced after upgrade
Answer: C, D
Explanation:
Upgrades can be performed online or offline (C):
Hitachi Vantara’s HCP G10 system supports both online and offline upgrades,
allowing administrators flexibility in how they choose to perform hardware upgrades.
This capability ensures that the system can be updated with minimal disruption to
operations. In an online upgrade, the system continues to run with full service
availability, while an offline upgrade typically requires bringing the system down. This
flexibility is critical for ensuring high availability and maintaining service level
agreements. Data is automatically rebalanced after upgrade (D):
After a hardware upgrade, such as adding new nodes, HCP automatically rebalances
the data across the cluster. This data rebalancing process is necessary to ensure that
data is evenly distributed across all nodes, maintaining efficient storage utilization and
performance. Rebalancing occurs as a background task without impacting the normal
operation of the platform. HCP's intelligent data placement algorithms manage this
process, ensuring optimized performance and data integrity. These two statements
accurately reflect how hardware upgrades and data management are handled in the
HCP G10 system, as per Hitachi Vantara's architecture.
Reference:
Hitachi Vantara HCP Installation and Configuration Guide
Hitachi Vantara HCP Administration and System Management Guide
G
et
V
al
2.In the event of a SAN-attached G10 node failure, which LUN configuration will
maintain access to a given set of data LUNs?
A. Data Protection Level 2
B. HCP LUN replicator
C. Zero Copy Failover
D. Dynamic multi-pathing
Answer: D
Explanation:
Dynamic Multi-Pathing (DMP) is a method that ensures continuous access to data in
the event of a node failure or path failure within a SAN environment. When a SANattached G10 node in a Hitachi Content Platform (HCP) fails, DMP allows for
automatic rerouting of data traffic to an alternate path without interruption. This is
accomplished by creating multiple physical paths between the storage devices and
E
xa
m
P
re
pa
ra
ti
on
the servers, ensuring that if one path fails, another can be utilized, thereby
maintaining access to data LUNs.
Hitachi Vantara Content Platform Installation
Reference: Dynamic Multi-Pathing (DMP): In the context of HCP, DMP is critical for
high availability and fault tolerance. It enables redundancy in connectivity between
nodes and storage arrays, ensuring continuous data access and minimal service
disruption in the event of hardware failure. This technology is designed to work in
SAN environments where multiple paths are configured between storage and
compute resources.
SAN-Attached G10 Node Failure: If a G10 node experiences failure, DMP comes into
play by dynamically redirecting I/O operations from the failed path to an alternative
path, ensuring uninterrupted access to data stored in the associated LUNs.
By using DMP, the system effectively prevents data loss or access interruption, which
is why this configuration is recommended for maintaining LUN access during node
failures in a SAN-attached HCP environment
G
et
V
al
id
H
it
ac
hi
H
Q
T
-4
42
0
D
um
ps
(V
8.
02
)
fo
r
3.When do you need to check the BIOS configuration on an HCP G10 node?
A. when replacing an entire node
B. when upgrading the HCP software version
C. when replacing a HBA
D. when replacing a failed hard disk drive
Answer: A
Explanation:
When replacing an entire HCP G10 node, it is necessary to check the BIOS
configuration. This ensures that the new hardware is correctly configured according to
the required specifications for the HCP system. The BIOS settings need to be
consistent with the rest of the cluster nodes to ensure proper functionality,
performance optimization, and hardware compatibility. This check might include
verifying boot order, enabling virtualization, setting appropriate hardware clock
configurations, and other critical settings outlined in the "Hitachi Vantara HCP G10
Installation and Configuration Guide."
4.You are installing a HCP G10 with attached storage. The system will be networked
using four 10 GbE SFP+ interfaces.
How many PCIe cards are installed in each HCP G10 node?
A. 1
B. 2
C. 3
D. 4
Answer: B
Explanation:
Each HCP G10 node with attached storage and networked using four 10 GbE SFP+
interfaces requires two PCIe cards. Typically, one PCIe card is allocated for network
connectivity, while the other is used for storage connectivity. The cards need to
support the necessary number of network interfaces and any additional connections
required for attached storage. The specific configuration depends on the HCP model,
but generally, two PCIe cards are sufficient to handle both networking and storage
interfaces as described in the "HCP G10 Hardware Installation Guide."
G
et
V
al
id
H
it
ac
hi
H
Q
T
-4
42
0
D
um
ps
(V
8.
02
)
fo
r
E
xa
m
P
re
pa
ra
ti
on
5.You are installing an HCP G10 and are now setting the front-end connectivity. The
customer has provided you with IP addresses for their network for each node.
Which two actions should be performed on each node as part of the OS installation?
(Choose two.)
A. Set the BMC IP address
B. Set the NTP IP address(es)
C. Set the front-end IP address
D. Set the gateway IP address
Answer: A, C
Explanation:
When installing an HCP G10 and setting up front-end connectivity, two critical actions
must be performed on each node:
Set the BMC IP Address (A): The Baseboard Management Controller (BMC) IP
address must be set to allow for remote management and monitoring of each node.
This is crucial for out-of-band management, especially in large data center
environments where physical access to servers may be limited. Configuring the BMC
IP address is typically done during the initial setup of the operating system on the
HCP node.
Set the Front-End IP Address (C): The front-end IP address, which is used for client
network traffic, must be configured as provided by the customer. This IP address
allows each node to communicate with the client network, and it is a key part of the
configuration during OS installation.
These configurations are detailed in the "HCP G10 Network Configuration Guide" and
the "HCP G10 Installation and Configuration Manual," which provide step-by-step
procedures for setting up both the BMC and front-end IP addresses.
6.You are installing an HCP G10 with attached storage. A VSP G1000 is used to
provision the storage
and is used by several applications.
Which action should be performed?
A. Shutdown the applications that use the VSP G1000
B. Enable shared storage optimization in the System Management Console
C. Enable the shared storage option on the G10 HBA
E
xa
m
P
re
pa
ra
ti
on
D. Specify that shared storage is used when prompted by the installation program
Answer: D
Explanation:
When installing an HCP G10 with attached storage using a VSP G1000, which is also
used by several other applications, it is crucial to configure the system properly to
allow shared storage use. The installation program for HCP G10 has a prompt that
allows you to specify that shared storage is being used. By selecting this option, the
system is informed that the VSP G1000 storage resources are shared among multiple
applications, allowing for proper configuration and optimization to prevent any
disruptions or conflicts. This ensures that HCP uses the storage without impacting
other applications relying on the same storage system.
Hitachi Vantara Content Platform Installation
Reference: When setting up an HCP G10, especially in environments with shared
storage configurations like the VSP G1000, the installation wizard will prompt for
shared storage settings to ensure compatibility and optimal configuration.
G
et
V
al
id
H
it
ac
hi
H
Q
T
-4
42
0
D
um
ps
(V
8.
02
)
fo
r
7.How is the software update package uploaded to an HCP S10?
A. using BMC
B. using an SFTP connection
C. using an SSH connection
D. using the Management Console
Answer: B
Explanation:
To upload a software update package to an HCP S10, an SFTP (Secure File Transfer
Protocol) connection is used. SFTP provides a secure way to transfer files between
the administrator's machine and the HCP S10 system. This method ensures that the
package is securely transmitted and prevents unauthorized access during the upload
process.
Hitachi Vantara Content Platform Installation
Reference: The HCP S10 system requires secure methods for software updates, and
SFTP is the recommended protocol for its ability to provide encryption and secure file
transfer.
8.What is the default password to log into the HCP G10 node BIOS?
A. Chang3Me!
B. hosyu95
C. install
D. xDCPr3set!
Answer: B
Explanation:
For HCP G10 nodes, the default password to access the BIOS is set to hosyu95. This
E
xa
m
P
re
pa
ra
ti
on
is a standard password used for initial access to the BIOS settings, allowing
administrators to configure the basic hardware settings of the HCP node.
BIOS Access:
The BIOS is the first layer of system settings that control how the hardware operates
before the system boots into the operating system or the HCP software. Accessing
the BIOS is usually necessary during the initial setup or hardware maintenance of
HCP nodes.
Security Considerations:
After initial setup, it is highly recommended to change the default BIOS password for
security reasons. Using default credentials like "hosyu95" can expose the system to
potential unauthorized access if left unchanged.
The default password is documented in the HCP G10 Installation Guides provided by
Hitachi Vantara, which emphasizes the importance of securing this access after
deployment.
Reference: Hitachi Vantara HCP G10 Installation and Administration Guide
Hitachi Vantara HCP G10 Security Configuration Best Practices
G
et
V
al
id
H
it
ac
hi
H
Q
T
-4
42
0
D
um
ps
(V
8.
02
)
fo
r
9.Which traffic type is allowed on the HCP back-end network?
A. BMC access
B. access to the Tenant Management Console
C. inter-node communication
D. replication traffic
Answer: C
Explanation:
The HCP back-end network is specifically designed to handle internal cluster traffic
such as inter-node communication. This traffic type is critical for maintaining cluster
synchronization, managing metadata, balancing loads, and ensuring consistent data
storage and retrieval across the nodes in the cluster. Other types of traffic, like BMC
access (A), tenant management console access (B), and replication traffic (D),
typically occur over separate management or front-end networks. The "HCP Network
Configuration and Management Guide" provides detailed information on network
segmentation and the roles of different network types in an HCP environment.
10.What is the minimum RAM capacity installed in a HCP G10 server?
A. 16 GB
B. 32 GB
C. 64 GB
D. 123 GB
Answer: C
Explanation:
The minimum RAM capacity installed in an HCP G10 server is 64 GB. This amount of
G
et
V
al
id
H
it
ac
hi
H
Q
T
-4
42
0
D
um
ps
(V
8.
02
)
fo
r
E
xa
m
P
re
pa
ra
ti
on
memory is required to handle the workload associated with managing large datasets,
metadata operations, indexing, data deduplication, and compression processes, all of
which are essential functions of the HCP platform. The "HCP Hardware Specification
Guide" outlines the minimum hardware requirements necessary to ensure optimal
performance and scalability of the platform.
GET FULL VERSION OF HQT-4420 DUMPS
Powered by TCPDF (www.tcpdf.org)
Download