FAN COILS, and ACCESSORY ELECTRIC HEATERS WIRING DIAGRAMS NOTE: Read the entire instruction manual before starting the installation . FIG. Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 6 Fig. 7 Fig. 1 Fig. 2 Fig. 2 Fig. 3 Fig. 4 Fig. 4 Fig. 5 Fig. 5 Fig. 8 Fig. 9 Fig. 8 Fig. 9 FIELDINSTALLED HEATER MODEL KFCEH0401N03B KFCEH0501N05B KFCEH0801N08B KFCEH0901N10B KFCEH1601315B KFCEH2001318B KFCEH2401C05B KFCEH2501C08B KFCEH2601C10B KFCEH2901N09B KFCEH3001F15B KFCEH3101C15B KFCEH3201F20B KFCEH3301C20B FB4C/ PF4MNP FE4A/ FE5A FH4C FV4C FX4D FY5B FZ4A PF4MA PF4MB LABEL 18,24 18-60 18-60 18-60 42-60 42-60 18-60 18-60 18-60 36-60 24-60 24-60 30-60 30-60 x 002-006 002-006 002-006 002-006 003-006 002-006 002-006 002-006 002-006 002-006 002-006 002-006 002-006 001 001-002 001-003 001-004 001-004 001-004 001-002 001-003 001-004 003-004 001-004 001-004 002-004 002-004 x 002-006 002-006 002-006 002-006 002-006 002-006 002-006 002-006 002-006 002-006 002-006 002-006 002-006 19,25 19-61 19-61 19-61 43-61 43-61 19-61 19-61 19-61 37-61 25-61 25-61 31-61 31-61 18,24 18-60 18-60 18-60 18-60 42-60 18-60 18-60 18-60 36-60 24-60 24-60 30-60 30-60 24 24-61 24-61 24-61 48-61 48-61 24-61 24-61 24-61 36-61 24-61 24-61 36-61 36-61 18,19,24,25 18-61 18-61 18-61 18-61 42-61 18-61 18-61 18-61 36-60 24-61 24-61 30-61 30-61 x 19-61 19-61 19-61 19-61 37-61 19-61 19-61 19-61 31-61 19-61 19-61 19-61 19-61 KFCEH3401F24B 48,60 004-006 003-004 005-006 49-61 48-60 48-61 48-61 49-61 KFCEH3501F30B 48,60 004-006 003-004 005-006 49-61 48-60 48-61 48-61 49-61 344631-101 344631-101 344599-101 344599-101 344635-101 344654-101 344631-101 344599-101 344599-101 344634-101 344597-101 344597-101 345611-101 345611-101 345655-101 345656-101 345655-101 345656-101 FAN COIL WITH RBC X-13 MOTOR OR BROAD OCEAN DIGI MOTOR FIG. Fig. 11 Fig. 10 Fig. 10 Fig. 12 Fig. 32 Fig. 30 Fig. 31 FACTORY-INSTALLED HEATER MODEL MKFCEH0501N05B MKFCEH0801N08B MKFCEH0901N10B MKFCEH1501F15B MKFCEH0501N05B MKFCEH0801N08B MKFCEH0901N10B MKFCEH1501F15B FB4C 18,24 18,30 24­48 36­60 ----- FX4D 19,25 31 37­61 61 ----- FZ4A ----24 LABEL 344637-101 344623-101 344771-101 36,48 344772-101 60,61 344773-101 344624-101 FAN COIL WITH COOLING ONLY CONTROL FIG. Fig. 13 Fig. 14 Fig. 15 Fig. 15 Fig. 16 Fig. 16 Fig. 17 Fig. 33 MODEL FV4C FE4A / FE5A FY5B / PF4MNA FH4C FB4C / FX4D / PF4MNP (RBC) PF4MNA/B FB4C / FX4D / PF4MNP (BOM) FZ4A SIZE 002-006 002-006 18-60 001-004 18-61 19,25,31,37,43,49,61 18-61 24-61 LABEL 326014-101 333107-101 328964-101 328964-101 336228-101 336228-101 337519-101 342415-101 50 HZ EXPORT FAN COILS FIG. Fig. 34 Fig. 35 MODEL FB4(C/Q)SL (Regal Beloit motor) FB4(C/Q)SL (Broad Ocean motor) SIZE 018-060 018-060 LABEL 336228-101 337519-101 : WIRING DIAGRAMS ELECTRIC HEATERS FIG. Fig. 18 Fig. 19 Fig. 19 Fig. 20 Fig. 21 Fig. 21 HEATER MODEL KFDEH0801D05A KFDEH0901D75A KFDEH1001D11A KFEEH0101D05A KFEEH0201D75A KFEEH0301D11A FF1E 18,24,30,36 18,24,30,36 18,24,30,36 19,25,31,37 19,25,31,37 19,25,31,37 FIG. HEATER MODEL CONTROL TYPE Fig. 22 EHK2­05B Sequencer ­ HS Fig. 22 EHK2­08B Sequencer ­ HS Fig. 22 EHK2­10B Sequencer ­ HS Fig. 23 Fig. 24 Fig. 24 Fig. 24 EHK205B EHK208B EHK210B Relay ­ HR Relay ­ HR Relay ­ HR LABEL 341080-101 341081-101 341081-101 341082-101 341083-101 341083-101 FFMA / FMA4 18,24,30,36 Prior to serial number date code 1715V. 18,24,30,36 Prior to serial number date code 1715V. 18,24,30,36 Prior to serial number date code 1715V. 18­37 Serial number date code 1715V and later. 18­37 18­37 18­37 LABEL 202070290385 202070290385 202070290385 2020702A717 06-7094-07 06-7094-07 06-7094-07 FIG. Fig. 25 Fig. 26 FFMA 19,31 25,37 LABEL --- FIG. FPM(A,B)N(C,U) Fig. 27 ALL with Time Delay Relay Fig. 28 ALL with Time Delay Board LABEL 202070290388 Valid for models FPM(A,B)N(C,U)0**000AAAA 2020702A1716 Valid for models FPM(A,B)N(C,U)T00ACAA FIG. Fig. 29 Fig. 29 Fig. 29 HEATER MODEL EHK305B EHK308B EHK310B FPMAN(C,U) 18­36 18­36 18­36 FPMBN(C,U) 18­30 18­30 18­30 FMC4 / FMU4 18­36 18­36 18­36 LABEL 06-7094-04 06-7094-04 06-7094-04 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 : WIRING DIAGRAMS 3 Kw & 5Kw 1Ø SCHEMATIC DIAGRAM HEATER VA: 1.75 COMPONENT ARRANGEMENT SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 DISCONNECT PER NEC GROUND FIELD POWER WIRING HTR1 DD1 L1 OR OR OR OR L2 L2 CB DD1 RELAY 1 6 YEL DISC DISC L1 HEAT STRIP-1 8 CB RELAY 1 22 VDC COIL RELAY 1 BLK YEL 4 2 BLU BLK BLK REC ORN VIO PLUG 2 9 7 11 3 LEGEND NOTES: 1. Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With N.E.C. And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire. CB FU FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE CIRCUIT BREAKER LINE FUSE DD GND HTR REC TDR 2 DUAL DEVICE LIMIT EQUIPMENT GROUND HEATER RECITFIER TIME DELAY RECITIFER 344631-101 REV.A A190003 Fig. 1 – Heaters KFCEH0401N03B / KFCEH0501N05B / KFCEH2401C05B 8 Kw & 10 Kw 1Ø SCHEMATIC DIAGRAM FIELD POWER WIRING OR OR OR OR L1 RELAY 2 YEL 6 DD2 YEL 9 HEAT STRIP-2 8 RELAY 1 6 PLUG 2 DISC CB YEL COMPONENT ARRANGEMENT HTR1 HTR2 DD1 DD2 L2 L2 DISC L1 HEATER VA: 3.5 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 DISCONNECT PER NEC GROUND HEAT STRIP-1 8 DD1 BLK BLK CB RELAY 2 4 2 BLK RELAY 1 22 VDC COIL BLK RELAY 1 4 2 REC BLU BLK ORN VIO 11 7 3 RELAY 2 22 VDC COIL RED/WHT BLK/WHT SEE NOTE #4 2 LEGEND NOTES: 1. Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With N.E.C. And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire. 4. Red Wire / White Stripe To QC1A, BLK Wire / White Stripe To QC2A. 5. Use 60 Amp class K Fuses Only, For Replacement. CB FU FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE CIRCUIT BREAKER LINE FUSE DD GND HTR REC TDR DUAL DEVICE LIMIT EQUIPMENT GROUND HEATER RECITFIER TIME DELAY RECITIFER 344599-101 REV.A Fig. 2 – Heaters KFCEH0801N08B / KFCEH0901N10B / KFCEH2501C08B / KFCEH2601C10B Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 A190004 : WIRING DIAGRAMS 1Ø / 3Ø FIELD CONVERTIBLE SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FIELD POWER WIRING HEATER VA: 5.25 9 Kw SCHEMATIC DIAGRAM HTR1 DISCONNECT PER NEC HTR3 DD1 HTR2 DD3 DD2 L2 L3 L1 COMPONENT ARRANGEMENT GROUND BLU YEL DD3 RELAY 3 6 BLU RELAY 3 HEAT STRIP-3 BLK 4 BLK 4 8 YEL FOR 3 PHASE WIRING Ø Denotes wire to be moved for 3 phase conversion. Dashed wire (- - -) indicates wiring after conversion. 1. Disconnect BLUE wire from Relay 1 Terminal 6, cut, strip, and connect to field wire L3. 2. Disconnect YELLOW wire from Relay 3 Terminal 6, and connect to Relay 1 Terminal 6. 3. Disconnect BLUE wire from Relay 3 Terminal 2, and connect to Relay 3 Terminal 6. BLK BLK 2 BLU BLU RELAY 2 6 YEL DD2 RELAY 2 HEAT STRIP-2 8 2 BLU YEL DD1 RELAY 1 BLU 6 RELAY 1 HEAT STRIP-1 8 4 BLK RELAY 2 22 VDC COIL RELAY 1 22 VDC COIL 2 BLK RED/WHT BLK/WHT SEE NOTE #4 REC BLK PLUG 2 ORN NOTES: 8 3 BRN RED ORN VIO ORN 5 7 11 9 REC IDR BLU YEL 6 2 RELAY 3 22 VDC COIL 4 LEGEND DD DUAL DEVICE LIMIT REC RECITFIER FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE 1. Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire. 4. Red Wire / White Stripe To QC1A, BLK Wire / White Stripe To QC2A. 5. Use 60 Amp class K Fuses Only, For Replacement. GND EQUIPMENT GROUND HTR HEATER IDR IDENTIFIER RESISTOR 344634-101 REV.A A190005 Fig. 3 – Heater KFCEH2901N09B 15 Kw 1Ø SCHEMATIC DIAGRAM HEATER VA: 5.25 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FIELD POWER WIRING COMPONENT ARRANGEMENT DISCONNECT PER NEC HTR1 HTR3 L3 L4 L2 CB1 CB2 CB2 CB1 L4 OR GND YEL RELAY 3 YEL YEL 6 8 RELAY 2 6 YEL 6 DD3 4 BLK 4 HEAT STRIP-3 BLK 8 9 11 BLK BLK BLK RELAY 2 2 BLK RELAY 1 22 VDC COIL RELAY 2 22 VDC COIL RELAY 1 4 2 TDR BLK 7 NOTES: GRY 5 GRY 8 ORN VIO 3 2 LEGEND 1. Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire. 4. Red Wire / White Stripe To QC1A, BLK Wire / White Stripe To QC2A. 5. Use 60 Amp class K Fuses Only, For Replacement. 6. IDR May Not Be Present In Some Applications. FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE CB CIRCUIT BREAKER FU LINE FUSE GND EQUIPMENT GROUND DD DUAL DEVICE LIMIT HTR HEATER RED 6 RELAY 3 22 VDC COIL RED/WHT BLK/WHT SEE NOTE #4 REC IDR BLK PLUG 2 2 BLU YEL DD2 RELAY 3 BLK HEAT STRIP-1 DD1 8 RELAY 1 YEL HEAT STRIP-2 DD2 DD3 L2 FU2 FU3 OR L1 FU4 L3 FU1 DD1 L1 HTR2 BRN 4 IDR IDENTIFIER RESISTOR REC RECITFIER TDR TIME DELAY RECITIFER 344597-101 REV.B Fig. 4 – Heaters KFCEH3001F15B / FCEH3101C15B Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4 A200124 : WIRING DIAGRAMS 20 Kw 1Ø SCHEMATIC DIAGRAM SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FIELD POWER WIRING HEATER VA: 7 COMPONENT ARRANGEMENT HTR3 HTR1 DISCONNECT PER NEC DD1 L3 L4 CB1 CB2 CB2 L2 L4 OR CB1 GND YEL BLK YEL DD1 RELAY 4 YEL 6 YEL 6 YEL 6 YEL 6 HEAT STRIP-1 8 RELAY 2 DD2 HEAT STRIP-2 LS-3 8 RELAY 1 LS-4 8 HEAT STRIP-3 HEAT STRIP-4 4 2 4 2 4 TDR BLK 2 4 BLK 2 REC IDR 8 NOTES: BLU 5 3 2 LEGEND 1. Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire. 4. Red Wire / White Stripe To QC1A, BLK Wire / White Stripe To QC2A. 5. Use 60 Amp class K Fuses Only, For Replacement. 6. IDR May Not Be Present In Some Applications. REC ORN VIO BLU 7 11 BRN RELAY 3 22 VDC COIL RELAY 1 BLK BU BLK PLUG 2 9 RED/WHT BLK/WHT SEE NOTE #4 RED RELAY 1 22 VDC COIL BLK BLU YEL RELAY 4 22 VDC COIL BLK RELAY 3 BLK BU BU RELAY 2 22 VDC COIL BLK RELAY 2 BLK 8 RELAY 3 RELAY 4 BLK L2 HTR4 L1 DD2 LS 3 & 4 FU2 FU1 OR FU4 L3 FU3 L1 HTR2 FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE CB CIRCUIT BREAKER GND EQUIPMENT GROUND BU BACK UP LIMIT GRY BRN 1 4 6 DD FU HTR IDR LS REC TDR DUAL DEVICE LIMIT LINE FUSE HEATER IDENTIFIER RESISTOR LIMIT SWITCH RECITFIER TIME DELAY RECITIFER 345611-101 REV.B A200061 Fig. 5 – Heaters KFCEH3201F20B / KFCEH3301C20B 15 Kw 3Ø SCHEMATIC DIAGRAM COMPONENT ARRANGEMENT SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 DISCONNECT PER NEC FIELD POWER WIRING HTR1 HTR3 DD1 GND L3 L1 HEATER VA: 5.25 HTR2 DD2 DD3 L2 BLU RELAY 3 6 DD3 HEAT STRIP-3 8 4 2 BLK BLU YEL RELAY 2 6 YEL BLK RELAY 3 BLK RELAY 1 6 DD2 HEAT STRIP-2 8 8 DD1 HEAT STRIP-1 RELAY 2 BLK 4 BLK 4 2 BLU BLK 11 7 2 RELAY 2 22 VDC COIL BLU RELAY 1 BLK RELAY 1 22 VDC COIL TDR RELAY 3 22 VDC COIL RED/WHT BLK/WHT SEE NOTE #4 REC YEL PLUG 2 9 ORN VIO 3 LEGEND NOTES: 1. Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire. 4. Red Wire / White Stripe To QC1A, BLK Wire / White Stripe To QC2A. 6 2 GND HVTB HTR REC MARKED TERMINAL TDR PLUG AND RECEPTACLE DD FIELD POWER WIRING RED BRN 4 EQUIPMENT GROUND HIGH VOLTAGE TERM. BLOCK HEATER RECITFIER TIME DELAY RECITIFER DUAL DEVICE LIMIT 344635-101 REV.A Fig. 6 – Heater KFCEH1601315B Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5 A190008 : WIRING DIAGRAMS Fig. 7 – Heater KFCEH2001318B Fig. 8 – Heaters KFCEH3401F24B / KFCEH3501F30B (single phase) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 6 A200060 A200062 : WIRING DIAGRAMS Fig. 9 – Heaters KFCEH3401F24B / KFCEH3501F30B (three phase) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7 A200063 : WIRING DIAGRAMS Fig. 10 – FB4C, FX4D - Heaters MKFCEH0801N08B / MKFCEH0901N10B Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8 A190013 : WIRING DIAGRAMS Fig. 11 – FB4C, FX4D - Heater MKFCEH0501N05B Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 9 A190015 : WIRING DIAGRAMS CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150V ALA TERRE 1Ø SCHEMATIC DIAGRAM COMPONENT ARRANGEMENT 15 Kw HEATER VA: 5.25 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FIELD POWER WIRING HTR1 HTR3 L3 L4 L2 CB2 CB2 CB1 L2 BLK BLK GND YEL YEL 6 BLK 8 6 BLK 8 DD3 RELAY 1 6 YEL 4 BLK GND RELAY 2 22 VDC COIL BLK RELAY 3 22 VDC COIL RELAY 1 4 BRN - C BLK - L YEL - N BLK 2 BLK 2 RELAY 1 22 VDC COIL BLU DD2 TDR C L G GRN/YEL - GND N RED/WHT BLK/WHT SEE NOTE #9 GND 208 V 230 V BRN RELAY 2 HEAT STRIP-3 8 2 DD3 COM RED 24 V RELAY 3 4 HEAT STRIP-1 DD1 RELAY 2 YEL HEAT STRIP-2 DD2 RELAY 3 YEL L4 OR TRAN L1 CB1 FU2 OR FU3 FU1 L3 FU4 DD1 L1 HTR2 DISCONNECT PER NEC FM BLU - 2 W HT -4 MOTOR CONNECTOR YEL BLK REC IDR GRY PLUG 9 9 7 7 11 11 8 2 2 3 3 VIO GRY SEE NOTE #5 4 5 G FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE UNMARKED TERMINAL CB CIRCUIT BREAKER COM COMMON LOW VOLTAGE F FUSE FM FAN MOTOR FU LINE FUSE GND EQUIPMENT GROUND HTR HEATER R RELAY REC RECTIFIER SPT FAN SPEED TAP LOCATION TRAN TRANSFORMER TDR TIME DELAY RECTIFIER DD DUAL DEVICE LIMIT MOTOR CONNECTOR L C POWER CONNECTION BLK 208/230V BRN 24V N G 2 1 3 YEL 208/230V BLU 4 5 NOTES: GRN/YEL WHT SPEED TAP SELECTON WHT R W THERMOSTAT CONNECTION FAN COIL WIRING SPEED TAP SELECTION LOW MEDIUM HIGH ELEC HEAT SEE NOTE 8 BRN C 1 2 3 4 5 3 LEGEND 4 4 Com FUSE BRN RED RED EL TRAN N/Y GR BRN 230 V COM 208 V BLU BLK 1 1 E WHT RESISTOR BRN 6 6 W3 W2 WHT YEL 2 BRN RED GRY 5 RECP 1 ORN VIO 1. Use copper wire (75ºC min.) only between disconnect switch and unit. 2. To be wired in accordance with N.E.C. and local codes. 3. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. 4. Replace low voltage fuse with no greater than 5 amp fuse. 5. To change speed tap, move blue wire to desired terminal. 6. Smaller heaters will have fewer components. 7. Connect R to R, G to G, etc., see outdoor instruction for details. 8. See airflow tables for tap usage. 9. Red Wire/WHT Stripe to QC1A, BLK Wire/WHT Stripe to QC2A. 10. N.E.C. class 2, 24 volts. 344623-101 REV.A Fig. 12 – FB4C, FX4D - Heater MKFCEH1501F15B Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 A190012 : WIRING DIAGRAMS a07029 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11 : WIRING DIAGRAMS Fig. 13 – FV4C with Cooling Only Control THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING CAUTION: AT TENTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION COOLING CONTROL ONLY COMPONENT ARRANGEMENT SEE RATING PLATE FOR VOLTS & HERTZ FIELD POWER WIRING DISCONNECT PER NEC SEE NOTE #1 7 5 BLU BLK COM BLU TRAN 24 V SEC2 4 3 2 6 1 4 VIO PCB SEC1 F U S E BRN BLK PLUG 3 BRN RED VIO BLU BLU 1 2 3 4 5 GRN/YEL GND PLUG 5 5 4 3 2 1 PLUG 1 ECM 2 1 4 3 2 1 BLU YEL 3 BLU YEL GRN RED RECP 4 RECP 3 1 BRN RED 230 V YEL 8 6 4 GRN RED RED BRN GND COMM ECM RED SYSTEM COMM. 11 2 CL5 OPN COM MOTOR SYSTEM TRANSFORMER: 40.0 VA FAN COIL: 4.0 VA REMAINING VA AVAILABLE: 36.0 VA NOTES: NON-COMMUNICATING OUTDOOR UNIT 9 3 OAT A B C D 7 RECP 2 YEL TROUBLE SHOOTING INFORMATION: FAULT / ACTION MOTOR F OFF OFF ON (FLASHING) ON (FLASHING) ON OFF 16 OTHER PCB HUM C O Y W G R 11 STATUS LED 208 V 230 V STATUS 9 MOTOR LED RED 24 V TRAN BRN BLK YEL PLUG 2 COM L2 GND L1 NE CONVIENT PAS A UX INSTALLATIONS DE PLUS DE 150 V A L A TERRE NOT RUNNING RUNNING NOT RUNNING RUNNING NONE - CHECK STATUS LED MOTOR MOTOR / HARNESS NONE FAULT / ACTION NONE - STANDBY MODE NO LOW VOLTAGE OR CONTROL - CHECK POWER AND FUSE NO SYSTEM COMMUNICATIONS - CHECK WIRING REFER TO SERVICE SCREENS ON USER INTERFACE OR THE FAN COIL TROUBLESHOOTING GUIDE 1. Use Copper Wire (75ºC Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With N.E.C. And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire. 4. Replace Low Voltage Fuse With No Greater Than 5 Amp Fuse. 5. For Use With Communicating Thermostat Only, Connect A To A, B To B, Etc. 6. Communicating Outdoor Units Connect A To A, B To B, Etc. 7. Non - Communicating Outdoor Units Connect R To R, Y To Y, Etc. LEGEND COM GND ECM OAT PCB RECP TRAN FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE COMMON EQUIPMENT GROUND FAN MOTOR OUTDOOR AIR THERMISTOR PRINTED CIRCUIT BOARD RECEPTACLE TRANSFORMER 333107-101 REV. B Fig. 14 – FE4A / FE5A with Cooling Only Control Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12 A12363 : WIRING DIAGRAMS NOTES 1. Use Copper Wire (75ºC Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With NEC And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire. 4. Replace Low Voltage Fuse With No Greater Than 5 Amp Fuse. 5. (3) Speed Motor Shown Optional (2) Speed Motor Uses HI (BLK) And LOW (BLUE or RED). 6. Connect R To R, G To G, Etc. See Outdoor Instruction For Details. 328964-101 REV. A Fig. 15 – FH4C / FY5B / PF4MNA with Cooling Only Control Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 13 a07027 : WIRING DIAGRAMS THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING BLOWER MOTOR ROTATION COOLING CONTROL ONLY SEE RATING PLATE FOR VOLTS & HERTZ FIELD POWER WIRING COM SEE NOTE #1 GND L1 COMPONENT ARRANGEMENT DISCONNECT PER NEC L2 230 V YEL RECP 7 4 3 7 4 3 2 6 1 2 6 1 WHT BLU WHT BLU VIO BRN SYSTEM TRANSFORMER: 40.0 VA FAN COIL: 5.0 VA REMAINING VA AVAILABLE: 35.0 VA E 11 11 9 9 W2 W3 PLUG C L G N 1 2 3 4 5 Speed Tap Power Connections Connections Motor Connections BRN RED C R BRN - C BLK - L YEL - N WHT W G THERMOSTAT CONNECTION FM GRN/YEL - GND BLU - 2 WH T-4 BRN SEE NOTE #6 GRN/YEL YEL BRN BLK L /YE TRAN N GR RED 208 V 230 V COM FUSE WHT GND GRY RESISTOR YEL BLU 24 V TRAN 208 V BLK SPEED TAP SELECTION 1 2 3 4 5 LOW MEDIUM HIGH ELEC HEAT SEE NOTE 7 NOTES 1. Use Copper Wire (75ºC Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With NEC And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced. Use The Same Or Equivalent Type Wire. 4. Replace Low Voltage Fuse With No Greater Than 5 Amp Fuse. 5. Connect R To R, G To G, Etc. See Outdoor Instruction For Details. 6. To change speed tap, move blue wire to desired terminal. 7. See airflow tables for tap usage. LEGEND C F FM GND RECP SPT TRAN COMMON LOW VOLTAGE FUSE FAN MOTOR EQUIPMENT GROUND RECEPTACLE FAN SPEED TAP LOCATION TRANSFORMER UNMARKED TERMINAL FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE 336228-101 REV. A Fig. 16 – FB4C / FX4D / PF4MNP (RBC) / PF4MNA/B with Cooling Only Control Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14 A12364 : WIRING DIAGRAMS Fig. 17 – FB4C / FX4D / PF4MNP (BOM) with Cooling Only Control Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 15 A12365 : WIRING DIAGRAMS Fig. 18 – FF1E - Heater KFDEH0801D05A Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16 A150114 : WIRING DIAGRAMS Fig. 19 – FF1E - Heaters KFDEH0901D75A / KFDEH1001D11A Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17 A150115 : WIRING DIAGRAMS Fig. 20 – FF1E - Heater KFEEH0101D05A Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18 A150116 : WIRING DIAGRAMS Fig. 21 – FF1E - Heaters KFEEH0201D75A / KFEEH0301D11A Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 19 A150117 : WIRING DIAGRAMS LS LS FL FL M3 M4 M1 M2 H H M3 M4 M1 M2 H H WHT DI S C 6 54 3 2 1 6 54 3 2 1 H M 1 M2 H 2 4 5 6 1 3 W HT GRN R ED H M1 M2 2 4 5 6 H 1 3 B LK 202 07 0290385 Fig. 22 – FFMANP(018,024,030,036 and EHK2 Electric Heaters with Sequencers NOTE: Representative for FFMANP(018,024,030,036) prior to serial number date code 1715V Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 20 A13131 : WIRING DIAGRAMS Fig. 23 – FFMANP(018,024,030,036 with PCB Time Delay NOTE: Representative for FFMANP(018,024,030,036) serial number date code 1715V and later. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 21 A150153 : WIRING DIAGRAMS Fig. 24 – EHK2 With Heater Relays Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 22 A190017 : WIRING DIAGRAMS CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION: NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE &/ $ 6 6 7+ ( 5 0 26 7 $ 7 &2 1 1 ( &7 , 2 1 6 COMPONENT ARRANGEMENT 5(6 %51 * 1' * 6( ( 12 7 ( 6(( 127( 6( ( 12 7 ( Fig. 25 – FFMANP(019, 031) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 23 A14323 : WIRING DIAGRAMS CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION: NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE &/ $ 6 6 7+ ( 5 0 26 7 $ 7 &2 1 1 ( &7 , 2 1 6 COMPONENT ARRANGEMENT 5(6 %51 * 1' * 6( ( 12 7 ( 6(( 127( 6( ( 12 7 ( Fig. 26 – FFMANP(025, 037) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24 A14324 : WIRING DIAGRAMS SCHEMATIC DIAGRAM SEE RATING PLATE FOR VOLTS&HERTZ CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION: NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE COMPONENT ARRANGEMENT + 385 %/.:+7 :+7 <(/ *51 5(' %/. 0 0 + + 0 0 + %/ . Fig. 27 – FPM(A,B)N(U,C) with Time Delay Relay Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 25 A14325 : WIRING DIAGRAMS SCHEMATIC DIAGRAM SEE RATING PLATE FOR VOLTS&HERTZ NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND FIELD POWER WIRING NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE CAUTION: ATTENTION: ELECTRIC HEAT WIRING CONNECTION (WHEN APPLIED) COMPONENT ARRANGEMENT SEE NOTE 6 TO T O T H E R M O S T AT SEE NOTE 1 AND NOTE 2 FM SEE NOTE 5 PUR SEE NOTE 4 GRN FM SEE NOTE 3 NOTES: 1: Use copper wire(75 min only between disconnect switch and unit, To be wired in accordance with N.E.C. and local codes. Fan coils equipped with electric heater connect power supply to terminal block.Cooling block.Cooling controls wiring not used with electric heaters. 2: If any of the original wire as supplied must be replaced,use the same or equivalent type wire. 3: Remove the red lead from 240V terminal and then connect the red lead to 208V terminal on the transformer for 208 volts. 4: Factory default fan speed is Medium,FM red wire connected to FR #4;For HI speed connect FM black wire to FR #4;For LOW speed connect FM blue wire to FR #4,and FM red wire connected to FR #6 . Always connect the unused FM wire to the dummy terminal block. 5: TDB has a 90-100s off delay when G is de-energized. 6:Connect R to R, G to G, etc. See outdoor or indoor instructions for details. 7:N.E.C.Class 2,24volts. Fig. 28 – FPM(A,B)N(C,U) with Time Delay Board Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 26 A170018 : WIRING DIAGRAMS L1 ATTENTION: HR1 BRN BLK RED/ WHT BLK HR2 BU1 BLK BLU BLK/WHT BLK/WHT BLK BLK/WHT 6 HPR 5 4 BRN 2 LIMIT L2 BLK BU2 HTR1 RED RED HTR HEATER BU LS RED/WHT RELAY HTR2 RED RED GND HPR LS 3 HR HEATER RELAY LS LIMIT SWITCH GND RED BRN 1 CAUTION: COOLING CONTROLS ELECTRIC HEAT L1 L2 WHT PUR YEL BLU BLK RED 654321 21 06-7094-04 Fig. 29 – EHK3 With Heater Relays Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 27 A190016 : WIRING DIAGRAMS CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING BLOWER MOTOR ROTATION NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150V ALA TERRE 1Ø SCHEMATIC DIAGRAM 8 Kw & 10 Kw COMPONENT ARRANGEMENT HEATER VA: 3.5 HTR1 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FIELD POWER WIRING LS1 DISCONNECT PER NEC GROUND HTR2 LS2 L1 OR DISC OR CB DISC OR RED 24 V L2 L2 OR CB TRAN COM L1 BRN - C BLK - L YEL - N GND RELAY 2 6 YEL DD2 YEL YEL HEAT STRIP-2 8 6 HEAT STRIP-1 8 RELAY 1 BLK RELAY 2 4 2 BLK BLK 4 2 REC 8 VIO BLU 2 3 4 5 LEGEND FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE UNMARKED TERMINAL CB CIRCUIT BREAKER COM COMMON LOW VOLTAGE F FUSE FM FAN MOTOR FU LINE FUSE GND EQUIPMENT GROUND HTR HEATER LS LIMIT SWITCH R RELAY REC RECTIFIER SPT FAN SPEED TAP LOCATION TRAN TRANSFORMER DD DUAL DEVICE LIMIT R WHT W G THERMOSTAT CONNECTION YEL C FAN COIL WIRING Y/Y2 MOTOR CONNECTOR POWER CONNECTION L C G BRN 24V GRN/YEL 4 4 BLU RED FUSE BRN RED BLK 208/230V 2 1 3 4 5 N BLU YEL SEE NOTE #5 1 1 E W3 WHT BRN BRN BRN YEL 208/230V WHT NOTES: 1 BLU YEL 230 V COM 208 V 6 6 W2 WHT RESISTOR RESISTOR YEL BLU EL TRAN N/Y GR SPEED TAP SELECTON YEL - 3 W HT -4 MOTOR CONNECTOR RELAY 2 22 VDC COIL RED/WHT BLK/WHT SEE NOTE #9 2 2 3 3 BLK LOW MEDIUM HIGH ELEC HEAT SEE NOTE 8 G 2 ORN VIO 5 RECP 1 2 3 4 5 L GRN/YEL - GND N BLU Com BRN 11 7 11 7 9 9 SPEED TAP SELECTION RELAY 1 22 VDC COIL BLU BLK YEL C BLK FM RELAY 1 DD1 YEL PLUG BLK GND 208 V 230 V BRN 1. Use copper wire (75ºC min.) only between disconnect switch and unit. 2. To be wired in accordance with N.E.C. and local codes. 3. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. 4. Replace low voltage fuse with no greater than 5 amp fuse. 5. To change speed tap, move blue wire to desired terminal. 6. Smaller heaters will have fewer components. 7. Connect R to R, G to G, etc., see outdoor instruction for details. 8. See airflow tables for tap usage. 9. Red Wire/WHT Stripe to QC1A, BLK Wire/WHT Stripe to QC2A. 10. N.E.C. class 2, 24 volts. 344772-101 REV. – Fig. 30 – FZ4A, 3 & 4 Ton, with MKFCEH 0801N08B / 0901N10B Heater Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 28 A190020 : WIRING DIAGRAMS CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150V ALA TERRE 1Ø SCHEMATIC DIAGRAM L3 L4 L2 CB2 CB2 CB1 L4 OR GND RELAY 3 YEL 6 YEL RELAY 2 6 YEL DD1 HEAT STRIP-1 8 RELAY 1 YEL BLK 8 6 DD3 HEAT STRIP-3 BLK BLK 8 RELAY 3 4 2 GND RELAY 2 4 2 BLK C RELAY 1 4 YEL 2 RELAY 1 22 VDC COIL 7 7 11 11 VIO WHT 4 5 FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE UNMARKED TERMINAL CB CIRCUIT BREAKER COM COMMON LOW VOLTAGE F FUSE FM FAN MOTOR FU LINE FUSE GND EQUIPMENT GROUND HTR HEATER LS LIMIT SWITCH R RELAY REC RECTIFIER SPT FAN SPEED TAP LOCATION TRAN TRANSFORMER TDR TIME DELAY RECTIFIER DD DUAL DEVICE LIMIT G W THERMOSTAT CONNECTION YEL R 3 LEGEND BLU C 2 4 4 Y/Y2 MOTOR CONNECTOR POWER CONNECTION L C FAN COIL WIRING BLK 208/230V BRN 24V N G 2 1 3 4 5 YEL 208/230V SEE NOTE #5 YEL - 3 W HT -4 BRN 1 1 E BLU RED FUSE BRN GRN/YEL BLU YEL LOW MEDIUM HIGH ELEC HEAT SEE NOTE 8 SPEED TAP SELECTON NOTES: WHT 1 2 3 4 5 W3 W2 BRN BRN BRN RED EL TRAN N/Y GR SPEED TAP SELECTION 6 6 BLU YEL 230 V COM 208 V 2 2 3 3 BLK 2 MOTOR CONNECTOR 1 BLK/WHT SEE NOTE #9 RED VIO WHT WHT RESISTOR RESISTOR YEL BLU YEL 8 5 RECP ORN BLU Com BR N 9 9 REC GRY FM RED/WHT TDR IDR GRY G RELAY 2 RELAY 3 22 VDC COIL 22 VDC COIL BLK PLUG L GND GRN/YEL - GND N BLK BLU LS2 208 V 230 V BRN - C BLK - L YEL - N BLK BLK HTR2 LS3 COM RED 24 V BRN HEAT STRIP-2 DD2 L2 TRAN L1 CB1 HTR3 LS1 FU2 OR FU3 FU1 L3 HTR1 DISCONNECT PER NEC FU4 FIELD POWER WIRING L1 COMPONENT ARRANGEMENT 15 Kw HEATER VA: 5.25 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 1. Use copper wire (75ºC min.) only between disconnect switch and unit. 2. To be wired in accordance with N.E.C. and local codes. 3. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. 4. Replace low voltage fuse with no greater than 5 amp fuse. 5. To change speed tap, move blue wire to desired terminal. 6. Smaller heaters will have fewer components. 7. Connect R to R, G to G, etc., see outdoor instruction for details. 8. See airflow tables for tap usage. 9. Red Wire/WHT Stripe to QC1A, BLK Wire/WHT Stripe to QC2A. 10. N.E.C. class 2, 24 volts. 344773-101 REV. – Fig. 31 – FZ4A, 5 Ton, with MKFCEH1501F15B Heater Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 29 A190021 : WIRING DIAGRAMS CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150V ALA TERRE 1Ø SCHEMATIC DIAGRAM 5Kw COMPONENT ARRANGEMENT HEATER VA: 1.75 HTR1 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 GROUND FIELD POWER WIRING LS1 DISCONNECT PER NEC L1 OR DISC OR CB DISC OR RED 24 V L2 L2 OR CB TRAN COM L1 BRN - C BLK - L YEL - N GND RELAY 1 6 YEL HEAT STRIP-1 DD1 8 RELAY 1 BLK 4 2 BLK C L G BLK FM GRN/YEL - GND N BLU YEL GND 208 V 230 V BRN BLU 2 YEL - 3 W HT -4 MOTOR CONNECTOR RELAY 1 22 VDC COIL 1 REC 2 3 4 5 ORN VIO 11 7 11 7 9 9 VIO 4 4 LEGEND FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE UNMARKED TERMINAL CB CIRCUIT BREAKER COM COMMON LOW VOLTAGE F FUSE FM FAN MOTOR FU LINE FUSE GND EQUIPMENT GROUND HTR HEATER LS LIMIT SWITCH R RELAY REC RECTIFIER SPT FAN SPEED TAP LOCATION TRAN TRANSFORMER DD DUAL DEVICE LIMIT WHT G W THERMOSTAT CONNECTION YEL R BLU C Y/Y2 FAN COIL WIRING MOTOR CONNECTOR L C POWER CONNECTION BLK 208/230V N G BRN 24V YEL 208/230V 2 1 3 GRN/YEL SEE NOTE #5 E FUSE BRN RED RED BRN 230 V COM BLU 4 5 1. 2. 3. 4. 5. 6. 7. 8. 9. YEL LOW MEDIUM HIGH ELEC HEAT SEE NOTE 8 SPEED TAP SELECTON NOTES: WHT 1 2 3 4 5 1 1 BLU YEL EL TRAN N/Y GR SPEED TAP SELECTION BLU BLK 208 V 6 6 W3 BRN BRN WHT WHT RESISTOR RESISTOR YEL BLU 2 2 3 3 W2 RECP YEL 8 5 Com BR N PLUG Use copper wire (75ºC min.) only between disconnect switch and unit. To be wired in accordance with N.E.C. and local codes. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. Replace low voltage fuse with no greater than 5 amp fuse. To change speed tap, move blue wire to desired terminal. Smaller heaters will have fewer components. Connect R to R, G to G, etc., see outdoor instruction for details. See airflow tables for tap usage. N.E.C. class 2, 24 volts. 344771-101 REV. – Fig. 32 – FZ4A, 2 Ton, with MKFCEH0501N05B Heater Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 30 A190019 : WIRING DIAGRAMS THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING BLOWER MOTOR ROTATION COOLING CONTROL ONLY SEE RATING PLATE FOR VOLTS & HERTZ FIELD POWER WIRING COM SEE NOTE #1 GND L1 COMPONENT ARRANGEMENT DISCONNECT PER NEC L2 BLK 7 3 4 3 2 6 1 2 6 1 W2 W3 9 RECP 4 WHT BLU C L G N 1 2 3 4 5 Speed Tap Power Connections Connections Motor Connections BRN BLU RED FUSE C R BRN SEE NOTE #6 GRN/YEL YEL EL N/Y TRAN R G GND YEL BLU RED COM 208 V 230 V RESISTOR YEL BRN BLK BRN BRN RESISTOR WHT BLU VIO YEL SYSTEM TRANSFORMER: 40.0 VA FAN COIL: 5.0 VA REMAINING VA AVAILABLE: 35.0 VA E 7 11 11 9 BLU YEL WHT 230 V YEL PLUG 24 V TRAN 208 V WHT Y/Y2 G THERMOSTAT CONNECTION W SPEED TAP SELECTION 1 2 3 4 5 BRN - C BLK - L YEL - N LOW MEDIUM HIGH ELEC HEAT SEE NOTE 7 NOTES 1. Use Copper Wire (75ºC Min) Only Between Disconnect Switch And Unit. 2. To Be Wired In Accordance With NEC And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced. Use The Same Or Equivalent Type Wire. 4. Replace Low Voltage Fuse With No Greater Than 5 Amp Fuse. 5. Connect R To R, G To G, Etc. See Outdoor Instruction For Details. 6. To change speed tap, move blue wire to desired terminal. 7. See airflow tables for tap usage. 8. N.E.C. class 2, 24 volts. FM GRN/YEL - GND -2 BLU YEL - 3 WH T-4 LEGEND UNMARKED TERMINAL FIELD POWER WIRING MARKED TERMINAL C F FM GND RECP SPT TRAN PLUG AND RECEPTACLE COMMON LOW VOLTAGE FUSE FAN MOTOR EQUIPMENT GROUND RECEPTACLE FAN SPEED TAP LOCATION TRANSFORMER 342415-101 REV. A Fig. 33 – FZ4A Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 31 A160101 : WIRING DIAGRAMS Fig. 34 – FB4(C/Q)SL Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 32 A170278 : WIRING DIAGRAMS Fig. 35 – FB4(C/Q)SL Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 33 A170279 : WIRING DIAGRAMS NOTES PAGE ©2020 CAC/BDP• 7310 W. Morris Street • Indianapolis, IN 46231 Edition Date: 02/20 Catalog No: WD-FANCOIL-10 Replaces: WD-FANCOIL-09 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 34