- INSTRUCTIONS The RY-24L Door Release Relay Module is an interface between the door strike contacts on the Aiphone monitor and the
actual release mechanism. The contact closure directly out of the monitor is rated at 12V AC with a low current capacity. If
your strike or maglock requires more voltage or current, the RY-24L is required. It provides either a Normally Open contact
for an electric strike, or a Normally Closed contact for a magnetic lock. The contact rating supports a majority of door
release hardware available on the market. The RY-24L relay is recommended with all KC, KB, and JA video systems
when using the door release feature. (Note: For more than one door release on the KB system, use the RY-3DL.)
INSTALLATION:
1. Install in a suitable location, either near the power source for the door release mechanism, or behind the monitor.
2. Secure wire connections with proper termination, such as wire nuts or crimp connectors.
3. Trim the wires to the desired length.
4. Trim the unused contact wire so the bare strands are not exposed.
RY-24L COLOR CODE:
KC-1GRD
Input of Relay:
WIRING DIAGRAMS:
KC-1MRD
Red:
L/ORG, Postive trigger
Black: (-) NEGATIVE
Output of Relay:
Brown: COMMON
Orange: N/O Contact
Yellow: N/C Contact
(See contact rating specs on
back page)
A1
1A1
B1
KC-DAR
A2
1A2
B2
+
-
RED:
BLK:
BRN:
ORG:
YEL:
L/ORG
(-) Neg.
Common
N/O
N/C
PS-2420UL
+
-
Master
KB-3MRD
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
Blk
Red
Brn
Org
Yel
Yel
Org
COM
N/O
S
S
LOCK
POWER
Connect
YELLOW
wire directly
to + on unit.
KB-DAR
A1
1A1
B1
A2
1A2
B2
2A1
MAGNETIC LOCK
WIRING METHOD:
To (-) of
power supply
(Normally Closed contact)
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
Blk
LOCK
POWER
2A2
Yel
COM
N/C
Use Brown & Yellow wires
when connecting to Maglock.
Connect
input as
shown
above.
Brn
Org
Yel
LOCK
POWER
PS-2420UL
3A2
Blk
Red
Brn
Org
3A1
Red
CN11
Org
Yel
+
-
+
-
Connect
YELLOW
wire directly
to + on unit.
Page 1
DISTRIBUTED BY: www.leedan.com
info@leedan.com
A2
Door 2
A1
A1
JA-DAC
A2
A2
C1
C2
RY-24L
(Normally Open contact)
Brn
Door
Release
#1
Org
Yel
LOCK
POWER
C1
COM
N/O
N/C
RY-24L
Door
Release
#2
Blk
Red
MAGNETIC LOCK
WIRING METHOD:
Brn
Org
(Normally Closed contact)
Blk
Red
C2
SUB
A1
A2
B1
B2
DOOR 2
A1
ADAPTER
1
Door 1
JA-DAC
DOOR 1
JA-2MECD
JA-2MCD
JA OPEN VOICE COLOR VIDEO ENTRY SYSTEM
ELECTRIC STRIKE
WIRING METHOD:
Toll-Free: 800-231-1414
ADAPTER
2
WIRING DIAGRAMS:
#1
Purp
Blu
Grn
Yel
Org
Red
Brn
#2
PS-2420UL
+
-
+
-
L1 (Brn)
L1 (Red)
L2 (Org)
L2 (Yel)
Yel
LOCK
POWER
Connect RED and
YELLOW wire on
JA--2MCD/-2MECD
directly to +
SPECIFICATIONS:
Power Source:
Mounting:
Terminations:
Relay Input:
Relay Output:
N/O Output rating:
Supplied by master station
No mounting required
Color-coded prewired pigtails
24-36V DC, Red, Black wires, 22AWG
Brown, Red, Orange wires, 18AWG
5A at 30V DC
10A at 125V AC
3A at 250V AC
N/C Ouptut rating:
3A at 30V DC or 125V AC
Wiring:
2 conductors from monitor's door release contacts to RY-24L.
2 conductors from RY-24L to release mechanism, with power wired in series.
Dimensions (HxWxD): 1-3/4" x 7/8" x 7/16", with wires extending approx. 7-1/2"