DRAWING INDEX: CLIENT: Broward County Facilities Management Division 115 S. Andrews Ave Fort Lauderdale, Florida 33301 DESIGN: NOVA Engineering & Environmental 650 Northlake Boulevard Suite 430 Altamonte Springs, FL 32701 SITE LOCATION: G-000 G-001 G-002 COVER SHEET PROJECT INFORMATION PROJECT INFORMATION A-100 A-101 A-102 A-103 ROOF PLAN WALKWAY PLAN LIGHTNING PROTECTION PLAN DRAINAGE PLAN A-200 A-201 A-202 DETAILS DETAILS DETAILS SCOPE OF WORK ROOFING OF ENVIRONMENTAL MONITORING LABORATORY 1. PREPARE EXISTING ROOFING MEMBRANE AS NEEDED TO RECEIVE NEW. (EXISTING MEMBRANE AND LIGHTWEIGHT INSULATING CONCRETE TO REMAIN.) 2. INSTALL NEW 12" GYPSUM COVER BOARD TO ENTIRE ROOF SURFACE, FULLY ADHERED AND MECHANICALLY ATTACHED TO/OVER EXISTING SYSTEM. 3. INSTALL NEW 2-PLY MODIFIED BITUMEN ROOFING SYSTEM 4. REPLACE ALL PRIMARY AND SECONDARY DRAINS 5. REPLACE ALL FLASHING 6. REPLACE ALL COPING TO MATCH EXISTING SIZE AND LOCATION 7. RAISE ALL PENETRATIONS AND CURBS AS NEEDED TO PROVIDE A MINIMUM OF 8" ABOVE FINISHED ROOF SYSTEM 8. INSTALL MANUFACTURER APPROVED WALKWAYS TO AND AROUND ALL MECHANICAL EQUIPMENT AS CALLED OUT ON DRAWINGS 9. REMOVE, REPLACE AND RECERTIFY LIGHTNING PROTECTION SYSTEM 10. REMOVE AND DISPOSE OF ALL DEBRIS IN A LEGAL MANNER 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com 3211 College Ave, Davie, Florida Installation of New Roofing System 3211 College Avenue Davie, Florida Broward County Environmental Monitoring Laboratory Environmental Monitoring Laboratory N PROFESSIONAL SEAL /COA Client: Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL Project No.: 10101-0522008 Checked: GY Drawn: Date: SAS 12/01/2022 Sheet Title: 3211 College Ave Davie, Florida Cover Sheet Sheet No. G-000 B. SUBSTITUTIONS: A. THIS SUMMARY OF WORK IS PROVIDED AS A GENERAL PERFORMANCE OUTLINE AND IS NOT INTENDED TO BE ALL-INCLUSIVE. REFER TO THIS PROJECT MANUAL AND PROJECT DRAWINGS FOR FURTHER DESCRIPTIONS. 1. 1. WORK INCLUDES ALL SPECIFIED WORK CALLED OUT IN MINIMUM PERFORMANCE REQUIREMENT SPECIFICATIONS AND DRAWINGS. 2. THE CONTRACTOR IS RESPONSIBLE FOR COMPLETING ALL SPECIFIED REQUIREMENTS NECESSARY TO PROVIDE FOR COMPLETED WORK BEING SOUND, DURABLE AND WATERTIGHT. 3. THE CONTRACTOR IS RESPONSIBLE FOR COMPLETING ALL CONTRACTED WORK IN STRICT ACCORDANCE WITH PROJECT REQUIREMENTS AND/OR MANUFACTURER REQUIREMENTS WHICHEVER IS MORE STRINGENT. 4. THE DRAWINGS REPRESENT THE FINAL REMEDIAL REPAIR PROJECT. THE CONSULTANT OR OWNER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, OR SEQUENCES FOR PROCEDURE OF CONSTRUCTION. 5. B. 1. 2. 3. C. 1. 2. 3. 4. 5. 6. NOT ALL DETAILS ARE CUT ON DRAWINGS. WHEN NOT PRESENT, USE MANUFACTURER DETAILS OR SUBMIT CUSTOM DETAIL FOR APPROVAL. PREPARATION: CONDUCT A COMPLETE INVESTIGATION OF THE EXISTING PROJECT CONDITIONS TO IDENTIFY THE AREAS OF WORK, EXTENT OF WORK AND CONSIDERATIONS REQUIRED TO COMPLETE THE WORK. NO CONSIDERATION WILL BE GIVEN TO CLAIMS BASED ON A DIFFERENCE BETWEEN ACTUAL AND ASSUMED CONDITIONS. COORDINATE ALL SITE INSPECTIONS WITH OWNER'S REPRESENTATIVES. TAKE FIELD MEASUREMENTS, VERIFY FIELD CONDITIONS AND CAREFULLY COMPARE SUCH FIELD MEASUREMENTS AND CONDITIONS AND OTHER INFORMATION KNOWN TO THE CONTRACTOR BEFORE COMMENCING ACTIVITIES. FIELD MEASUREMENTS MUST BE TAKEN. DESTRUCTIVE ANALYSIS DURING THE BID PREPARATION IS ALLOWABLE TO FIELD VERIFY ALL CONDITIONS. CONTRACTORS SHALL BE RESPONSIBLE FOR EFFECTIVELY REPAIRING ANY FIELD CUTS THE SAME DAY OF INSPECTION TO OWNER'S SATISFACTION. COORDINATE ALL ACTIVITIES WITH OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH DESTRUCTIVE TESTING. DRAWINGS FROM ORIGINAL CONSTRUCTION ARE NOT AVAILABLE FOR THIS PROJECT. OWNER NOR CONSULTANT ARE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS RESULTING FROM THE USE OF BID DOCUMENTS OR PROVIDED CONSTRUCTION DRAWINGS. PROJECT CONDITIONS: A. MOBILIZATION: C. CODES AND STANDARDS: INCLUDE DELIVERY AND SET UP OF ALL MATERIALS, EQUIPMENT AND INCIDENTAL ITEMS NECESSARY TO SAFELY ACCESS AREAS OF WORK TO COMPLETE SPECIFIED ROOFING WORK. PROPERLY STORE ALL MATERIALS AND EQUIPMENT IN DESIGNATED PROJECT STAGING AREAS AS APPROVED BY OWNER. CONTRACTORS SHALL BE RESPONSIBLE FOR MOBILIZATION AND MAINTAINING SCAFFOLDING, SAFETY BARRICADES, OVERHEAD PROTECTION, BUILDING PROTECTION, LANDSCAPE PROTECTION AND PROJECT SIGNAGE REQUIRED FOR THE PROJECT FOR THE FULL DURATION OF THE PROJECT. COORDINATE ALL MOBILIZATION OF EQUIPMENT, MATERIALS AND INCIDENTAL ITEMS WITH OWNER AND LOCAL GOVERNING AUTHORITIES IN ACCORDANCE WITH PRE-APPROVED PROJECT SCHEDULE. 1. PROJECT INCLUDES INSTALLATION OF NEW ROOFING SYSTEM. 2. INSPECT EXISTING CONDITION OF ALL SURFACES TO RECEIVE NEW ROOFING SYSTEM FOR DAMAGE AND OR DETERIORATIONS. REPORT TO ENGINEER ALL UNSATISFACTORY CONDITIONS. 3. PREPARE EXISTING ROOFING MEMBRANE AS NEEDED TO RECEIVE NEW. (EXISTING MEMBRANE AND LIGHTWEIGHT INSULATING CONCRETE TO REMAIN.) 4. INSTALL NEW 12" GYPSUM COVER BOARD TO COMPLETE ROOFING SYSTEM, FULLY ADHERED AND MECHANICALLY ATTACHED TO/OVER EXISTING SYSTEM TO REMAIN. 5. INSTALL NEW 2-PLY SBS MODIFIED BITUMEN ROOFING SYSTEM FOLLOWING SPECIFIED DRAWINGS AND MANUFACTURERS REQUIREMENTS. 6. INSTALL NEW PRIMARY AND SECONDARY DRAINS. PROVIDE ALTERNATE PRICING FOR INSTALLATION OF RETRO-FIT DRAINS. 7. INSTALL NEW SHEET METAL FLASHINGS, COUNTERFLASHINGS, REPLACE VENTS TO MATCH EXISTING AND ALL ASSOCIATED MATERIALS REQUIRED TO PROVIDE A COMPLETE WATERTIGHT ROOFING SYSTEM. 8. ALL EXISTING COPING TO BE REPLACED WITH NEW COPING MATCHING EXISTING SIZE AND LOCATION. 9. REMOVE, REPLACE AND RECERTIFY LIGHTNING PROTECTION SYSTEM MINIMUM STANDARD NFPA 780. 10. INSTALL NEW WALKWAYS PER DRAWINGS. 11. PROVIDE PAYMENT AND PERFORMANCE BONDS AS REQUIRED BY OWNER. PROTECT THE BUILDING, THE PROPERTY, THE BUILDING OCCUPANTS AND THEIR PROPERTY. 12. INCLUDE A CONTINGENCY FOR MISCELLANEOUS AND UNKNOWN CONDITIONS UNCOVERED OF $10,000 WITHIN BASE BID. PROVIDE PROTECTIVE BARRICADES, ENCLOSURES, DIRECTIONAL AND WARNING SIGNAGE AND OTHER METHODS TO ASSURE SAFE PASSAGE OF PEDESTRIANS AND VEHICLES IN, NEAR AND AFFECTED BY AREAS OF THE WORK. 13. DISPOSE OF ALL DEBRIS IN A LEGAL MANNER. DO NOT DISRUPT SERVICES OR BLOCK EGRESS. THERE SHALL BE NO INTERFERENCE WITH LIFE SAFETY FEATURES. IN CASE OF A STORM EVENT OR OTHER NATURAL OCCURRENCES, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVAL OF CONSTRUCTION EQUIPMENT AND MATERIALS FROM PROJECT SITE AND/OR SUFFICIENTLY STORED AT LOCATIONS ACCEPTABLE TO OWNER(S). ALL CONSTRUCTION ACTIVITIES APPROVED BY OWNER SHALL BE CONDUCTED AT TIMES PRE-APPROVED BY THE OWNER IN ACCORDANCE WITH THE APPROVED PROJECT SCHEDULE. CONTRACTOR SHALL PROVIDE SUFFICIENT MANPOWER AND EQUIPMENT TO COMPLETE CONTRACTED WORK WITHIN ALLOTTED SCHEDULE. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION, SUCH MEASURES SHALL INCLUDE, BUT NOT LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS.) PRODUCTS AND DESIGN OF SYSTEMS INDICATED ON THE DESIGN DRAWINGS AND WITHIN THESE SPECIFICATIONS SHALL BE CONSIDERED AS "SPECIFIED STANDARD" OF QUALITY. NO SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE CONSULTANT. 1. ALL WORK SHALL BE IN STRICT COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE AND AUTHORITIES HAVING JURISDICTION. 2. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INSPECTIONS AND PAY ALL FEES. D. PRODUCTS: 1. ALL PRODUCTS, ETC., SHALL BE NEW UNLESS OTHERWISE NOTED, AND AS SPECIFIED FREE OF DEFECTS AS SHOWN ON THE DRAWINGS AND AS INDICATED IN THESE SPECIFICATIONS. E. WORKMANSHIP: 1. ALL MATERIALS SHALL BE FABRICATED AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER WITH THE COORDINATION OF ALL INVOLVED TRADES TO AVOID INTERFERENCES AND DELAY DUE TO LACK OF COORDINATION. NO ALLOWANCES WILL BE MADE FOR REWORK DUE TO COORDINATION DIFFICULTIES OR INTERFERENCES BETWEEN INVOLVED TRADES. Broward County Environmental Monitoring Laboratory GENERAL: 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com 1.02 SUMMARY OF WORK 3211 College Ave, Davie, Florida GENERAL REQUIREMENTS PROFESSIONAL SEAL /COA Client: Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL Project No.: 10101-0522008 Checked: GY Drawn: Date: SAS 12/01/2022 Sheet Title: Project Info Sheet No. G-001 SYMBOLS AC UNIT ON SLEEPERS V ATTIC VENT C CAPPED CURB V CURB MOUNTED VENT C-1 EVP EVAP. COOLER LV CD DS G AREA DENOTES 4' WIDE STRIP AT PERIMETER WHERE 1/2" PLYWOOD TO BE USED INSTEAD OF 1/2" FIBREBOARD (PLY) GUY WIRE ANCHOR PIPE PENETRATION PP PITCH PAN CONDENSATION DRAIN LINE COLUMN CAP PLUMBING VENT DOWNSPOUT POWER ROOF VENT GUTTER ROOF HATCH LADDER MECHANICAL SCREEN OVERFLOW DRAIN ROOF HATCH W/ PAVERS ROUND GOOSENECK (DUCT) RD ROOF DRAIN ROOF HATCH W/ WALKWAY RD ROOF DRAIN IN SUMP ROOF VENT PIPE SCUPPER POWER VENT OVERFLOW SCUPPER SATELLITE DISH N NORTH ARROW SLOPE T TRANSFORMER WALKWAY - RAISED OF CHIMNEYS SCUPPER W/ CONDUCTOR HEAD HOT STACK SPLASH BLOCK MASONRY CHIMNEY WALL DRAIN ROOF CONDITIONS SOLAR COLLECTOR BLISTERING BL PERIMETERS PIPE RUNS CRICKET FS FS SADDLE G G 3' WALKWAY DEBRIS L ADJACENT BUILDING E E 3' TRANSITION WALL SKYLIGHT SC CRICKETS NOT INCLUDED IN CONTRACT NIC OD TURBINE VENT 4' BALLAST MECHANICAL UNIT SQUARE GOOSENECK (DUCT) HS ANTENNA GRAVITY VENT PIPE CHASE LOUVRED VENT HV AC GAS LINE PENETRATION DRAINAGE DUCT PENETRATION EXHAUST FAN G CONFIRMED MOISTURE DAMAGE 4' ABANDONED FAN CORE SAMPLE W/INDENTIFIER ELECTRIC CONDUIT AD AREA DIVIDER EJ EJ EXPANSION JOINT GS GAS LINE PF PICTURE FRAMING GRAVEL STOP OR METAL FASCIA PONDING PARAPET WALL RIDGING PH PENTHOUSE RE RAISED ROOF EDGE R LEAK AREA MEMBRANE HOLE AD FIRE SPRINKLER ;INE SM SPLIT MEMBRANE VEGETATION RIDGE TRANSITION WALL V VALLEY MATERIALS LEGEND ABBREVIATIONS TONGUE & GROOVE POLYISOCYANURATE LWIC-LIGHT WEIGHT INSULATED CONCRETE GLASS GYPSUM BOARD DENS DECK GYPSUM BOARD BATT INSULATION METAL PORTLAND CEMENT PLASTER PLYWOOD PORTLAND CEMENT PLASTER OVER METAL LATH WOOD BLOCKING EXTERIOR INSULATION & FINISH SYSTEM CONTINUOUS WOOD MEMBER COMPRESSIBLE FILLER FINISHED WOOD MEMBER CONCRETE EARTH 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com AC A F A/C AFF @ BD BLDG BLK BLK'G BUR CL CJ CLG CMU COL CONC CONT CU DIA DN DS DWG EWC EJ EL EXP EXST'G FP FJ FIN FL FLASH'G GA GALV GL HM HP AIR CONDITIONING ABOVE FINISHED FLOOR AT BOARD BUILDING BLOCK BLOCKING BUILD UP ROOFING CENTER LINE CONTROL JOINT CEILING CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CONDENSING UNIT DIAMETER DOWN DOWN SPOUT DRAWING ELECTRIC WATER COOLER EXPANSION JOINT ELEVATION EXPANSION EXISTING FIREPROOF FIELD JOINT FINISH FLOOR FLASHING GAUGE GALVANIZED GLASS HOLLOW METAL HIGH POINT INSUL JT LAM LAV LP MAX MECH MTL MIN MO NA NIC OC OPEN'G(OPN'G) PL PLAS. LAM. PLYWD PT RAD RD REQD SS SUSP. CLG. STL SQ THK TREAT'D TOM TOS TYP VTR VIF W/ W/O WD INSULATION JOINT LAMINATE LAVATORY LOW POINT MAXIMUM MECHANICAL METAL MINIMUM MASONRY OPENING NOT APPLICABLE NOT IN CONTRACT ON CENTER OPENING PLATE PLASTIC LAMINATE PLYWOOD PRESSURE TREATED RADIUS ROOF DRAIN REQUIRED STAINLESS STEEL SUSPENDED CEILING STEEL SQUARE THICK TREATED TOP OF MASONRY TOP OF STEEL TYPICAL VENT THRU ROOF VERIFY IN FIELD WITH WITHOUT WOOD 3' 4' 3211 College Ave, Davie, Florida AC UNIT ON CURB MISCELLANEOUS PENETRATIONS CORE SAMPLE AC Broward County Environmental Monitoring Laboratory CORES/MOISTURE AIR HANDLING EQUIPMENT F 3' 4' 4' 4' PROFESSIONAL SEAL /COA Client: CORNER AND PERIMETER ZONE WIDTH: 10% OF LEAST OVERALL DIMENSION OR 40% OF HEIGHT EXISTING WOOD SUBSTRATE CODE INFORMATION DESIGN CRITERIA APPLICABLE CODES DESIGN WIND SPEED - 170 MPH Building : FLORIDA BUILDING CODE Edition : 2020 Mechanical : FLORIDA MECHANICAL CODE Edition : 2020 Plumbing : FLORIDA PLUMBING CODE Edition : 2020 Electrical : NATIONAL ELECTRICAL CODE Edition : 2017 Fire : FLORIDA FIRE PREVENTION CODE Edition : NA Energy: FLORIDA ENERGY CONSERVATION CODE Edition : 2020 RISK CATEGORY - II EXPOSURE - B BUILDING HEIGHT - 30' STRENGTH DESIGN METHOD (SDM) PER ASCE 7-16 Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL Project No.: 10101-0522008 LEGEND FIELD ZONE 1 Checked: GY Drawn: ZONE 1 (FIELD) - 99.4 PSF ZONE 2 (PERIMETER) - 131.2 PSF ZONE 3 (CORNER) - 178.7 PSF PERIMETER ZONE 2 CORNER ZONE 3 ALLOWABLE STRESS DESIGN - SDM x 0.6 PRESSURE ZONES PLAN 1 UPLIFT SCALE: 1" = 20' N Date: SAS 12/01/2022 Sheet Title: Project Info Sheet No. G-002 1 A-202 TYP. TYP. 3 A-200 4 A-200 3 A-202 3 A-201 TYP. 1 A-201 OD RD 1 A-202 RD TYP. TYP. TYP. RD 2 A-202 TYP. 3 A-202 RD RD TYP. RD 4 A-202 TYP. TYP. RD 4 A-201 3 A-202 TYP. TYP. 3 A-200 1 A-202 TYP. TYP. 4 A-200 4 A-200 OD RD RD RD Broward County Environmental Monitoring Laboratory TYP. 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com 4 A-201 3 A-201 TYP. TYP. 1 A-201 TYP. 3 A-202 TYP. OD 4 A-201 1 A-202 2 A-201 TYP. RD TYP. 3 A-201 RD 1 A-201 PROFESSIONAL SEAL /COA Client: Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL TYP. TYP. Project No.: 10101-0522008 Checked: GY Drawn: LEGEND TYP. RD ROOF DRAIN OD SECONDARY OVERFLOW ROOF DRAIN HVAC F MECHANICAL UNIT EXHAUST FAN PIPE PENTRATION AC SL PP SCUPPER OD 3 A-200 TYP. Date: ROOF HATCH CD AC UNIT ON CURB CONDENSATION DRAIN LINE EQUIPMENT CURB SAS 12/01/2022 Sheet Title: 4 A-200 SKYLIGHT PITCH PAN 3211 College Ave, Davie, Florida TYP. TYP. 1 ROOF PLAN SCALE: 1/16" = 1'-0" N Roof Plan Sheet No. A-100 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com RD RD RD RD RD RD OD RD RD RD 3211 College Ave, Davie, Florida OD Broward County Environmental Monitoring Laboratory RD OD RD PROFESSIONAL SEAL /COA Client: Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL RD Project No.: 10101-0522008 Checked: OD GY Drawn: LEGEND Date: RD ROOF DRAIN OD SECONDARY OVERFLOW ROOF DRAIN HVAC F MECHANICAL UNIT SCUPPER EXHAUST FAN WALK PADS Sheet Title: PIPE PENTRATION AC SL PP AC UNIT ON CURB SKYLIGHT PITCH PAN ROOF HATCH CD CONDENSATION DRAIN LINE EQUIPMENT CURB SAS 12/01/2022 1 WALKWAY PLAN SCALE: 1/16" = 1'-0" N Walkway Plan Sheet No. A-101 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com LIGHTNING PROTECTION ARRESTOR (TYP.) RD RD LIGHTNING PROTECTION ARRESTOR (TYP.) RD RD RD RD OD RD RD RD 3211 College Ave, Davie, Florida Broward County Environmental Monitoring Laboratory OD RD OD RD PROFESSIONAL SEAL /COA Client: 1. REMOVE AND REPLACE EXISTING LIGHTNING PROTECTION SYSTEM AT ALL LOCATIONS IT CURRENTLY EXISTS. CONTRACTOR TO RE-CERTIFY LIGHTNING PROTECTION. MINIMUM STANDARD FOR INSTALLATION NFPA 780 STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION SYSTEMS. 2. 3. Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL RD Project No.: 10101-0522008 Checked: OD GY Drawn: LEGEND RD ROOF DRAIN OD SECONDARY OVERFLOW ROOF DRAIN HVAC F MECHANICAL UNIT EXHAUST FAN PIPE PENTRATION SL PP AC AC UNIT ON CURB CD CONDENSATION DRAIN LINE LIGHTNING PROTECTION ARRESTOR (TYP.) SCUPPER PITCH PAN EQUIPMENT CURB 1 LIGHTNING PROTECTION PLAN SCALE: 1/16" = 1'-0" SAS 12/01/2022 Sheet Title: LIGHTNING PROTECTION SKYLIGHT ROOF HATCH Date: N Lightning Protection Plan Sheet No. A-102 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com SLOPE SLOPE RD SLOPE RD RD RD RD SLOPE SLOPE RD SLOPE SLOPE RD SLOPE SLOPE SLOPE RD SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE OD RD RD RD 3211 College Ave, Davie, Florida Broward County Environmental Monitoring Laboratory OD RD SLOPE SLOPE OD RD PROFESSIONAL SEAL /COA Client: Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL SLOPE RD OD LEGEND RD ROOF DRAIN OD SECONDARY OVERFLOW ROOF DRAIN HVAC F MECHANICAL UNIT SCUPPER EXHAUST FAN WALK PADS Project No.: 10101-0522008 Checked: SLOPE NOTE: SLOPE SHOWN IS FROM THE EXISTING STRUCTURE/LIGHTWEIGHT INSULATING CONCRETE. NO NEW SLOPE IS BEING INTRODUCED. Drawn: Date: AC PP AC UNIT ON CURB SKYLIGHT PITCH PAN ROOF HATCH CD CONDENSATION DRAIN LINE EQUIPMENT CURB SAS 12/01/2022 Sheet Title: PIPE PENTRATION SL GY 1 DRAINAGE PLAN SCALE: 1/16" = 1'-0" N Drainage Plan Sheet No. A-103 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com LAP SEAMS AS REQUIRED BY MANUFACTURER, MINIMUM OF 4" NEW 2-PLY MODIFIED BITUMEN ROOFING SYSTEM EXISTING LIGHTWEIGHT INSULATING CONCRETE MIN EXISTING METAL DECK EXISTING LIGHTWEIGHT INSULATING CONCRETE EXISTING ROOF ASSEMBLY 1 2 SCALE: N.T.S. EXISTING METAL DECK NEW ROOF SYSTEM SCALE: N.T.S. REMOVE EXISTING COPING CAP. INSTALL NEW COPING, SIZE TO MATCH EXISTING (VARIES) MIN FASTENERS APPROX. 8'' O.C. REMOVE EXISTING ASSEMBLY AS NECESSARY TO ACCESS AND REMOVE EXISTING CANT. INSTALL NEW NON-COMBUSTIBLE CANT OR PROVIDE MANUFACTURER APPROVED DETAIL CORNER MIN 5" M1 8" IMU M1 NEW CONTINUOUS FLASHING CLEAT IMU 8" CONTINUOUS WEATHERPROOF MEMBRANE ON TOP OF WALL, TURNED DOWN BOTH SIDES SLOPE WELDED NEW COPING NEW MEMBRANE FLASHING PLIES Broward County Environmental Monitoring Laboratory EXISTING SINGLE-PLY MEMBRANE NEW 12" GYP BOARD, FULLY ADHERED AND MECHANICALLY ATTACHED 3211 College Ave, Davie, Florida EXISTING SINGLE-PLY MEMBRANE COVER PLATE, 8" MIN EXISTING LIGHTWEIGHT INSULATING CONCRETE NEW 2-PLY MODIFIED BITUMEN ROOFING SYSTEM ADD 12" GYP BOARD MECHANICALLY ATTACHED TO INTERIOR OF PARAPET WALL SLOPE 4" MIN JOINT LAP, SET IN CONTINUOUS BED OF SEALANT EXISTING SINGLE PLY MEMBRANE NEW 12" GYP BOARD, FULLY ADHERED AND MECHANICALLY ATTACHED PROFESSIONAL SEAL /COA 4" MIN LAP 1" LAP MIN Client: Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL FASTEN CONTINUOUS CLEAT USING FASTENERS AT 6" O.C. Project No.: 10101-0522008 FASTEN AT 8" O.C. Checked: Drawn: Date: MIN. 2 FASTENERS NEW COPING EXISTING METAL DECK 3 PARAPET DETAIL SCALE: N.T.S. 4 COPING LAP DETAIL SCALE: N.T.S. GY SAS 12/01/2022 Sheet Title: Details Sheet No. A-200 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com NEW CAST ALUMINUM DRAIN INSERT WITH SEALING GASKET (NO PLASTIC) AS APPROVED BY THE ROOF MEMBRANE MANUFACTURER. REPLACE ALL COMPONENTS REMOVE EXISTING FLASHING AS NECESSARY TO INSTALL NEW MANUFACTURER APPROVED FLASHING NEW LIQUID FLASHING MEMBRANE AS SPECIFIED BY MANUFACTURER NEW 1/2" GYP BOARD NEW 12" GYP BOARD, FULLY ADHERED AND MECHANICALLY ATTACHED EXISTING LIGHTWEIGHT INSULATING CONCRETE EXISTING METAL DECKING REMOVE AND REPLACE EXISTING DRAINS, PROVIDE ALTERNATE FOR USE OF RETROFIT DRAINS 1 2 SECONDARY DRAIN DETAIL SCALE: N.T.S. ROOF DRAIN DETAIL SCALE: N.T.S. EXTEND PIPE PENETRATIONS AS NEEDED TO PROVIDE A MINIMUM OF 8" ABOVE FINISHED ROOFING SYSTEM EXISTING PENETRATION. CLEAN, PRIME, AND PREPARE AS RECOMMENDED BY FLASHING MANUFACTURER. EXTEND HEIGHT AS REQUIRED SEALANT (TOOLED) EPDM WASHERED FASTENERS (8" O.C.) REMOVE EXISTING LEAD SLEEVE FLASHING AND INSTALL NEW LEAD FLASHING. PRIME AND SET IN APPROVED MASTIC AS RECOMMENDED BY MANUFACTURER EXISTING SINGLE PLY MEMBRANE TO REMAIN SEALANT (TOOLED) NEW 12" GYP BOARD, FULLY ADHERED AND MECHANICALLY ATTACHED METAL COUNTER FLASHING MEMBRANE FLASHING PLIES 8" MIN. ALUMINUM TERMINATION BAR, FASTEN WITH APPROVED FASTENERS (8" O.C.) NEW MEMBRANE FLASHING PLIES Broward County Environmental Monitoring Laboratory DRAIN SUMP TO EXTEND 18" ON ALL SIDES 2" RAISED COLLAR EXISTING SINGLE PLY MEMBRANE 3211 College Ave, Davie, Florida NEW 2-PLY MODIFIED BITUMEN ROOFING SYSTEM EXISTING SINGLE PLY MEMBRANE EXISTING LIGHTWEIGHT INSULATING CONCRETE SUBSTRATE TO REMAIN BONDING ADHESIVE PROFESSIONAL SEAL /COA Client: NEW SEALANT NEW 2-PLY MODIFIED BITUMEN ROOF SYSTEM Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL Project No.: 10101-0522008 EXISTING METAL COUNTER FLASHING TO REMAIN Checked: GY Drawn: Date: NEW METAL COUNTER FLASHING SAS 12/01/2022 Sheet Title: EPDM WASHERED FASTENERS (8" O.C.) 3 WALL COUNTERFLASHING DETAIL SCALE: N.T.S. EXISTING METAL DECK Details MEMBRANE FLASHING PLIES BONDING ADHESIVE 4 PIPE PENETRATION DETAIL SCALE: N.T.S. Sheet No. A-201 PRIME PENETRATION WITH M-1 EXTENDING UP 3" FROM BASE OF PENETRATION. DO NOT USE ROOF CEMENT. 8" MIN. REMOVE EXISTING ASSEMBLY AS NECESSARY TO ACCESS AND REMOVE EXISTING CANT. INSTALL NEW NON-COMBUSTIBLE CANT NEW MEMBRANE FLASHING PLIES EXISTING SINGLE PLY MEMBRANE EXISTING LIGHTWEIGHT INSULATING CONCRETE EXISTING SINGLE PLY MEMBRANE NEW 2-PLY MODIFIED BITUMEN ROOFING SYSTEM A MINIMUM 1" SPACE IS REQUIRED BETWEEN ALL PENETRATIONS AND THE INTERIOR WALL OF ALL CHEMCURBS. CHEMCURB SECTIONS (5" OR 7.5" I.D.) EXTERNAL BEAD OF M-1 M-1 STRUCTURAL SEALANT SCARF JOINTS 2 CHEMCURB DETAIL SCALE: NTS EXISTING METAL DECK WOOD CURB 1 PREFAB METAL CURB CURB / HATCH DETAIL SCALE: NTS GASKETED FASTENERS SHEET METAL FASCIA CAP A FASTEN BASE FLASHING 8" O.C. EXTEND ONE BASE FLASHING PLY BELOW BLOCKING MULTIPLE-PLY MEMBRANE BASE FLASHING FEATHERED AT FIELD OF ROOF. (FOR ROOF SYSTEMS WITH FACTORY-APPLIED GRANULE SURFACING, THE MULTI-PLY MEMBRANE BASE FLASHING CAN BE INSTALLED BETWEEN THE BASE PLY AND GRANULE-SURFACED SHEET.) WOOD CANT FASTENED TO BLOCKING WOOD NAILERS CONTINUOUS CLEAT FASTENED 6" O.C. 1" MIN. BELOW BLOCKING 650 Northlake Boulevard, Suite 430 Altamonte Springs, FL 32701 407.902.2660 - www.usanova.com 1" MIN INSPECT EXISTING BLOCKING. INSTALL NEW WOOD BLOCKING IF EXISTING IS DETERIORATED OR DOES NOT MEET HEIGHT MINIMUM. NEW 12" GYP BOARD, FULLY ADHERED AND MECHANICALLY ATTACHED NEW 2-PLY MODIFIED BITUMEN ROOFING SYSTEM FILL CHEMCURBS WITH ONLY 1-PART POURABLE SEALER WHEN INSTALLING ON GRANULATED MEMBRANES. ON ALL OTHER ROOF MEMBRANES PRO PACK POURABLE SEALER CAN BE USED. 3211 College Ave, Davie, Florida EXISTING MECHANICAL EQUIPMENT/VENT TO REMAIN, DISCONNECT AND REINSTALL AS NECESSARY. SET IN CONTINUOUS SEALING MATERIAL NEW FLASHING RECEIVER REMOVE EXISTING AND INSTALL NEW REMOVABLE COUNTERFLASHING EXISTING CURB TO BE REPLACED ON NEW MECHANICAL UNITS. CLEAN AND PRIME CURBS TO REMAIN. INSPECT AND REPLACE INSULATION/BLOCKING AS NECESSARY 1 " MIN 2 Broward County Environmental Monitoring Laboratory ADD ADDITIONAL WOOD BLOCKING AS NEEDED TO PROVIDE MINIMUM OF 8" CURB HEIGHT FASTEN WITH STAINLESS STEEL SCREWS AND NEOPRENE WASHERS 6" O.C. NOTE: AFTER ALL EQUIPMENT IS INSTALLED APPLY POLYURETHANE FOAM TO SEAL OPENINGS. BUTYL TAPE LEGEND: CRIMP EDGE - A PROFESSIONAL SEAL /COA Client: Broward County Facilities Management 115 S. Andrews Ave Fort Lauderdale, FL A APPROX. 4" NEW 1/2" GYP BOARD, FULLY ADHERED AND MECHANICALLY ATTACHED Project No.: 10101-0522008 MIN. 12" Checked: EXISTING LIGHTWEIGHT INSULATING CONCRETE EXISTING SINGLE PLY MEMBRANE A SCALE: NTS GY Drawn: Date: SAS 12/01/2022 Sheet Title: A 3 RAISED ROOF EDGE DETAIL SCALE: NTS NEW 2-PLY MODIFIED BITUMEN ROOFING SYSTEM EXISTING METAL DECK 4 MECHANICAL WIRE HOOD SCALE: NTS Details Sheet No. A-202