ETR GEN5-2022-17 Parameter file testing Frame 71 Tango Motor

advertisement
Engineering Test Report (ETR)
Project / DV Plan
and Rev no.:
SG3.01_-_DV_test_plan_-_Frame 71 Lafert
motors_rev8
Parameter file testing for Tango pump
1.25x1.25x5(1.5kW,3600 rpm) &
1.5x1.5x3 (1.1kW, 4500 rpm)
Test ID:
Test description:
Motor starting behavior test at different
conditions
ETR number:
Gen5-2022-17
Prepared by:
Masum M
Prepared date:
2022-06-06
Approved by:
Approved date:
Conclusions:
1.25x1.25x5
For Tango 1.25x1.25x5 (4.960” impeller) with motors 1.5kW kW, Three Phase, 230V, 3600rpm, TEFC, VFD
FW 2.0D
Starting Current (Peak value) was set to 2.08 A (25.4% of motor rated current), Max Open Loop speed set to
1200RPM, Startup Time set to 5s
Wet High Load Test: Ramp up at BEP point.


Left motor: N 1851498-004 01 22 L1
Right motor: N 1851498-003 01 22 L1
PASS
PASS
Wet Low Load Test: Ramp up when control valve was closed.


Left motor: N 1851498-004 01 22 L1
Right motor: N 1851498-003 01 22 L1
PASS
PASS
1.5x1.5x3:
For Tango 1.5x1.5x3 (3.05” impeller) with motors 1.1 kW, Three Phase, 230V, 4500rpm, TEFC, VFD FW 2.0D
Starting Current (Peak value) was set to 3.37 A (55.4% of motor rated current), Max Open Loop speed set to
1500RPM, Startup Time set to 5s
Wet High Load Test: Ramp up at BEP point.


Left motor: N 1814218-002 (new sticker, same sample as Rev0)
Right motor: N 1814218-003(new sticker, same sample as Rev0)
PASS
PASS
Wet Low Load Test: Ramp up when control valve was closed.


Left motor: N 1814218-002 (new sticker, same sample as Rev0
Right motor: N 1814218-003(new sticker, same sample as Rev0)
FAILED
PASS
Engineering Test Report (ETR)
1. Objective / Purpose of test:
To determine and record any errors that occur during motor start under high and low load on
Tango pumps.
2. Test condition summary:
1.25x1.25x5:
Test Preparation Time:
0.5 hours
Test Start Date:
2022-06-02
Test Finish Date:
Total Duration:
Critical test conditions
Summary:
2021-06-02
0.5 Day
N/A
Test Preparation Time:
1 hours
Test Start Date:
2022-06-03
Test Finish Date:
Total Duration:
Critical test conditions
Summary:
2021-06-06
1.5 Day
N/A
1.5x1.5x3:
3. Samples Tested:
Sample ID
Sample received date
Sample Serial number:
Tango 1.25x1.25x5 3 Phase 230V 1.5kW
3600RPM
Tango 1.5x1.5x3 3 Phase 230V 1.1kW
4500RPM
N/A
1.25x1.25x3
Left Motor: N 1851498-004 01 22 L1
Right motor: N 1851498-003 01 22 L1
1.5x1.5x3
Left Motor: N 1814218-002 01 22 L1
Right motor: N 1814218-003 01 22 L1
Sample supplier
Part number / drawing and revision #
Hardware and Firmware rev #
Electrical / mechanical / temperature
rating
Motors from Lafert, Pump assembled by Armstrong
Type: iECM 71 3600 1.5 58 200 B14/105
P.N.: N/A
Type: iECM 71 4500 1.1 43 200 B14/105
P.N. :N/A
DEPC: 1.33.00, VFD Firmware: 2.0 D
Two motors: 1.5 kW, 3Phase-230 V, 3600rpm,
TEFC motors
Two motors: 1.1 kW, 3Phase-230 V, 4500rpm,
Engineering Test Report (ETR)
Special construction of sample
TEFC motors
Pump size:
Tango 1.25 x 1.25 x 5 (4.96” impeller) TEFC
Pump size:
Tango 1.5 x 1.5 x 3 (3.05” impeller) TEFC
4. Pass/Fail Criteria Summary:
1.25 x 1.25 x 5
Pass Criteria
Motor starts and
continues to run
without issue or
error.
Test condition
PASS/Total trial attempts
Pass 10 of 10
Wet High Load (Left
Pump Ramp Up)
Second motor is running
Second motor stopped
Pass 10 of 10
Wet High Load (Right
Pump Ramp Up)
Second motor is running
Pass 10 of 10
Second motor stopped
Pass 10 of 10
Wet Low Load (Left
Pump Ramp Up)
Second motor is running
Pass 10 of 10
Second motor stopped
Pass 10 of 10
Wet Low Load (Right
Pump Ramp Up)
Second motor is running
Pass 10 of 10
Second motor stopped
Pass 10 of 10
1.5 x 1.5 x 3
Pass Criteria
Motor starts and
continues to run
without issue or
error.
Test condition
PASS/Total trial attempts
Pass 10 of 10
Wet High Load (Left
Pump Ramp Up)
Second motor is running
Second motor stopped
Pass 10 of 10
Wet High Load (Right
Pump Ramp Up)
Second motor is running
Pass 10 of 10
Second motor stopped
Pass 10 of 10
Wet Low Load (Left
Pump Ramp Up)
Second motor is running
FAILED
Second motor stopped
FAILED
Wet Low Load (Right
Pump Ramp Up)
Second motor is running
Pass 10 of 10
Second motor stopped
Pass 10 of 10
5. Equipment:


R&D TR17
Equipment
Flow Sensor
Head Sensor
Cert. Number/
S. N
23905
N08AA0210011
Accuracy
Calibration Due
0.25%
0.5%
Jul,31, 2024
May 31,2023
Engineering Test Report (ETR)
6. Environmental / Safety Requirements:
Safety of personnel and equipment shall be considered paramount. To ensure safety during the
testing all activities must be regulated in accordance with the Armstrong Safety Plan
Regulations. In addition, Work instructions (ENG LAB 001 Rev2) must be following up and check
list (appendix of ENG LAB 001 Rev.2) have been filled before testing sample installation and
dismantled on the TR or TT. If TR or TT modification requested, Engineering Labs Test
Equipment Service, Repair and Modification Form (SRMF-2021-03) must be filled and approved.
Additional safety requirements due to Covid-19: Face mask, maintain social distancing – 6’ (2 m)
7. Procedure:
Install the Pump sample on the Test Rig and fill up with water before the following test.
Testing sequence: Wet High Load test, Wet Low Load test
Verify Motor Shaft Power, Motor Input Current and Motor Input Voltage from DEPC
Wet High Load Test:
Test condition: BEP performance point. Valve opening adjusted to reach BEP.
Test condition: Suction valve closed, no waterflow.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Set the right-side motor direction to clockwise and set the left-side motor direction to
counterclockwise direction settings.
Set pump to optimum BEP speed.
Adjust suction valve to reach flow and head close to BEP point.
Start the right-side motor when the left side motor stopped.
Observe whether motor starts or not. Note any fault code(s) or unusual behavior.
In the case of successful start:
- Record pump successful start and stop the pump.
In the case of non-successful start:
- Record Pump not started.
Try to start motor 10 times and record the results.
Start the left side motor at BEP.
Repeat step 2 – 10 while left side motor stopped and right-side motor ramp up 10 times at
optimum BEP speed.
Repeat step 2 – 10 while left side motor running and right-side motor ramp up 10 times at
optimum BEP speed.
Repeat step 2 – 10 while right side motor stopped and left-side motor ramp up 10 times at
optimum BEP speed.
Repeat step 2 – 10 while right side motor running and left-side motor ramp up 10 times at
optimum BEP speed.
Wet Low Load Test:
Test condition: Suction valve closed, no waterflow.
1. Set the right-side motor direction to clockwise and set the left-side motor direction to
counterclockwise direction settings.
2. Set pump to optimum BEP speed.
3. Fully close the control valve at suction.
Engineering Test Report (ETR)
4. Start the right side motor when the left side motor stopped.
5. Observe whether motor starts or not. Note any fault code(s) or unusual behavior.
6. In the case of successful start:
- Record pump successful start and stop the pump.
7. In the case of non-successful start:
- Record Pump not started.
8. Try to start motor 10 times and record the results.
9. Start the left side motor at BEP.
10. Repeat step 2 – 10 while left side motor stopped and right-side motor ramp up 10 times at
optimum BEP speed.
11. Repeat step 2 – 10 while left side motor running and right-side motor ramp up 10 times at
optimum BEP speed.
12. Repeat step 2 – 10 while right side motor stopped and left-side motor ramp up 10 times at
optimum BEP speed.
13. Repeat step 2 – 10 while right side motor running and left-side motor ramp up 10 times at
optimum BEP speed.
8. Results and Analysis Summary:
1.25x1.25x5
Pump Size: Tango 1.25x1.25x5, impeller: 4.96”
Motor (Parameter) Type: Single phase 200-240V, 1.5kW, 3600RPM, TEFC
Pump BEP from E-3212: @Preferred Speed 3345 RPM, flow 59.6GPM, head 73.1Ft_H2O
VFD FW Version: 2.0D
DEPC FW Version: 1.33.00
Number of restarts = 3
Used KMD monitor to control the ramping up motor and DEPC to control the other motor
Parameter file after adjusting and used for the following tests:
Tangro 1.25x1.25x5
(4.96)imp 1.5kW 3p .xml
KMD Log Files data:
Frame 71 3ph 230V 1.5kW 3600RPM Parameter file verification.zip
Set Starting Current Peak = 2.08A (25.4 of rated current)
Set Max open loop speed = 1200RPM
Set Startup Time = 5s
Engineering Test Report (ETR)
Wet High Load Test:
Left motor ramps up to 3345 RPM with Right motor running @ 3345 RPM, 59.6 GPM, 73.1 Ft_H2O
Try #1
Try #2
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Try #1
Try #2
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Left motor ramps up to 3345 RPM with Right motor off
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Right motor ramps up to 3345 RPM with Left motor running @ 3345 RPM, 59.6 GPM, 73.1 Ft_H2O
Try #1
Try #2
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Try #1
Try #2
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Right motor ramps up to 3345 RPM with Left motor off
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Wet Low Load Test:
Left motor ramps up to 3345 RPM with Right motor running @ 3345 RPM, Control valve fully closed
Try #1
Try #2
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Try #1
Try #2
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Left motor ramps up to 3345 RPM with Right motor off
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Engineering Test Report (ETR)
Right motor ramps up to 3345 RPM with Left motor running @ 3345 RPM, Control valve fully closed
Try #1
Try #2
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Try #1
Try #2
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Right motor ramps up to 3345 RPM with Left motor off
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
1.5x.1.5x3
Pump Size: Tango 1.5x1.5x3, impeller: 3.05”
Motor (Parameter) Type: Single phase 200-240V, 1.1kW, 4500RPM, TEFC
Pump BEP from E-3212: @Preferred Speed 4695 RPM, flow 70.7GPM, head 49.2Ft_H2O
VFD FW Version: 2.0 D
DEPC FW Version: 1.33.00
Number of restarts = 3
Used KMD monitor to control the ramping up motor and DEPC to control the other motor
Parameter file was used for the following tests:
Tango 1.5x1.5x3
(3.05)imp 1.1kW 3p .xml
KMD Log Files data:
1.5x.1.5x3 1.1kW 3ph 4500 rpm_Tango.zip
Set Starting Current Peak = 3.37A (55.4% of rated current)
Set Max open loop speed = 1500RPM
Set Startup Time = 5s
Wet High Load Test:
Left motor ramps up to 4695 RPM with Right motor running @ 4695 RPM, 70.7 GPM, 49.2 Ft_H2O
Try #1
Try #2
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Engineering Test Report (ETR)
Try #1
Try #2
PASS @
initial
start
PASS @
initial
start
Left motor ramps up to 4695 RPM with Right motor off
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Right motor ramps up to 4695 RPM with Left motor running @ 4695 RPM, 70.7 GPM, 49.2 Ft_H2O
Try #1
Try #2
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Try #1
Try #2
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Right motor ramps up to 4695 RPM with Left motor off
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
G
Wet Low Load Test:
Left motor ramps up to 4695 RPM with Right motor running @ 4695 RPM, Control valve fully closed
Try #1
Try #2
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
Try #9
Try #10
PASS @
Initial
Initial
Initial
Initial
Initial
Initial
Initial
initial
Start
Start
Start
Start
Start
Start
Start
Start 
then
then
then
then
then
then
then
PASS @
stop
PASS @
Stopped
Stopped
Stopped Stopped Stopped
Stopped Stopped
initial
and
initial
Alarm 2
Alarm 2
Alarm 2 Alarm 3 Alarm 2
Alarm 2 Alarm 3
start
started
start
Needed
Needed
Needed Needed Needed
Needed Needed
again
Reset
Reset
Reset
Reset
Reset
Reset
Reset
No
FAILED
FAILED
FAILED
FAILED
FAILED
FAILED
FAILED
Alarm
Engineering Test Report (ETR)
Try #1
Try #2
Initial
Start
Failed
Alarm 2
Needed
Reset
FAILED
Initial
Start
then
Stopped
Alarm 2
Needed
Reset
FAILED
Left motor ramps up to 4695 RPM with Right motor off
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
PASS @ PASS @
Initial
Initial
Initial
initial
initial
Start
Start
Start
Start  Start 
then
then
then
PASS @
stop
stop
Stopped Stopped Stopped
initial
and
and
Alarm 2 Alarm 2 Alarm 2
start
started started
Needed Needed Needed
again
again
Reset
Reset
Reset
No
No
FAILED
FAILED
FAILED
Alarm
Alarm
Try #9
PASS @
initial
start
Try #10
Initial
Start
then
Stopped
Alarm 2
Needed
Reset
FAILED
2
Right motor ramps up to 4695 RPM with Left motor running @ 4695 RPM, Control valve fully closed
Try #1
Try #2
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
Try #1
Try #2
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Right motor ramps up to 4695 RPM with Left motor off
Try #3
Try #4
Try #5
Try #6
Try #7
Try #8
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
PASS @
initial
start
Try #9
Try #10
PASS @
initial
start
PASS @
initial
start
9. Photographs:
1.25x1.25x5:
Fig. 1 Motors Nameplates (Right motor N 1851498-003 01 22 L1,1.5kW ,3600 rpm ,PN: N/A)
Engineering Test Report (ETR)
Fig. 2. Motors Nameplates (Left motor N 1851498-004 01 22 L1,1.5kW, 3600 rpm, PN: N/A)
1.5x1.5x3:
Fig 3. Motors Nameplates (Right motor N 1814218-003 01 22 L1,1.1kW, 4500 rpm PN: N/A)
Fig. 4. Motors Nameplates (Right motor N 1814218-002 01 22 L1,1.1kW, 4500 rpm PN: N/A)
Engineering Test Report (ETR)
PLM Location:
Aras Innovator (armstrongfluidtechnology.com)
File Summary:
Revision
Rev 0
Description
Original Release (1.25x1.25x5 4.96” imp. 1.5 kW)
Original Release (1.5x1.5x3 3.05” imp. 1.1 kW)
Date
2022-06-06
Download